Performance Characteristics of Automobile Air Conditioning Using the R134a/R1234yf Mixture

被引:7
|
作者
Shin, Yunchan [1 ]
Kim, Taejung [2 ]
Lee, Areum [1 ]
Cho, Honghyun [3 ]
机构
[1] Chosun Univ, Dept Mech Engn, Grad Sch, Gwangju 61452, South Korea
[2] Korea Polytech VI, Dept Automobile, Yeongju Campus, Yeongju 36142, South Korea
[3] Chosun Univ, Dept Mech Engn, Gwangju 61452, South Korea
基金
新加坡国家研究基金会;
关键词
COP (coefficient of performance); exergy destruction; exergy efficiency; GWP (global warming potential); R1234yf; R1234YF/R134A MIXTURE; REFRIGERANT R1234YF; R134A REPLACEMENTS; EXERGY ANALYSIS; ORC SYSTEMS; TEMPERATURE; HFC134A;
D O I
10.3390/e22010004
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In this study, the energy and exergy of an automobile refrigeration system using R134a and R134a/R1234yf were analyzed experimentally with respect to outdoor air temperature and compressor speed. As outdoor air temperature increased from 32.5 degrees C to 37.5 degrees C, the coefficient of performance (COP) and total exergy destruction rate of the refrigeration system using Mix30 decreased by 5.19% and 25.8% on average, compared to that of the system using R134a. The exergy efficiency of the Mix30 refrigeration system was on average 21.8% higher than that of the R134a system. As the compressor rotating speed increased from 1000 to 2000 rpm, the cooling capacity of the refrigeration system using R134a and R134a/R1234yf increased, while the COP decreased. The COP and total exergy destruction rate of the refrigeration system using Mix30 decreased by 4.82% and 19.5%, compared to that of the system using R134a. The exergy efficiency of the Mix30 refrigeration system increased on average by 20.7%, compared to that of the R134a system. The total exergy destruction rate of the automobile refrigeration system using R134a/R1234yf decreased with increase in R1234yf, while exergy efficiency increased. In addition, the exergy destruction rate of the automobile refrigeration system decreased as the amount of R1234yf in the R134a/R1234yf automobile refrigeration system increased.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Investigation of using R134a, R1234yf and R513A as refrigerant in a heat pump
    A. Yıldız
    R. Yıldırım
    International Journal of Environmental Science and Technology, 2021, 18 : 1201 - 1210
  • [32] Comparative Analysis of Heat Pump System with IHX Using R1234yf and R134a
    Santa, Robert
    PERIODICA POLYTECHNICA-MECHANICAL ENGINEERING, 2021, 65 (04): : 363 - 373
  • [33] The refrigerant R1234yf in air conditioning systems
    Zilio, Claudio
    Brown, J. Steven
    Schiochet, Giovanni
    Cavallini, Alberto
    ENERGY, 2011, 36 (10) : 6110 - 6120
  • [34] Experimental investigation of the effects of compressor types on the performance of an automobile air conditioning system using R1234yf
    Alkan, Alpaslan
    Inan, Mehmet Sait
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 58 - 66
  • [35] Experimental comparison of an air-to-water refrigeration system working with R134a and R1234yf
    Illan-Gomez, F.
    Garcia-Cascales, J. R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 124 - 131
  • [36] Experimental study on the operating characteristics of a display refrigerator phasing out R134a to R1234yf
    Morales-Fuentes, A.
    Ramirez-Hernandez, H. G.
    Mendez-Diaz, S.
    Martinez-Martinez, S.
    Sanchez-Cruz, F. A.
    Silva-Romero, J. C.
    Garcia-Lara, H. D.
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2021, 130 : 317 - 329
  • [37] Performance evaluation of an automobile air conditioning system using R134a
    Esen, Dilek Ozlem
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 4952 - 4958
  • [38] Exergoeconomic performance comparison of R1234yf as a drop-in replacement for R134a in a domestic refrigerator
    Rangel-Hernandez, V. H.
    Belman-Flores, J. M.
    Rodriguez-Valderrama, D. A.
    Pardo-Cely, D.
    Rodriguez-Munoz, A. P.
    Ramirez-Minguela, J. J.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 100 : 113 - 123
  • [39] Experimental study on the flammability ofanew type of refrigerant R1234yf/R134a
    Chen, Guangming (gmchen@zju.edu.cn), 1600, Science Press (37):
  • [40] Performance Analysis of Refrigerants R1234yf, R1234ze and R134a in Ejector-Based Refrigeration Cycle
    Yadav, Ajay Kumar
    Neeraj
    INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2018, 26 (03)