Continuous quantitative monitoring of powder mixing dynamics by near-infrared spectroscopy

被引:53
|
作者
Koller, D. M. [1 ]
Posch, A. [1 ]
Hoerl, G. [1 ]
Voura, C. [1 ]
Radl, S. [2 ]
Urbanetz, N. [1 ,2 ]
Fraser, S. D. [1 ]
Tritthart, W. [3 ]
Reiter, F. [3 ]
Schlingmann, M. [3 ]
Khinast, J. G. [1 ,2 ]
机构
[1] Res Ctr Pharmaceut Engn GmbH, Graz, Austria
[2] Graz Univ Technol, Inst Proc Engn, A-8010 Graz, Austria
[3] GL Pharma GmbH, Lannach, Austria
关键词
Quantitative continuous monitoring; Powder mixing dynamics; Blend uniformity; Process analytic technology; Near-infrared spectroscopy; Multivariate analysis; EFFECTIVE SAMPLE-SIZE; GRANULAR FLOW; BLEND HOMOGENEITY; TRANSMISSION; TABLETS; CHEMOMETRICS; SPECTROMETRY; SEGREGATION; PARTICLES; MIXER;
D O I
10.1016/j.powtec.2010.08.070
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
FT-NIR spectroscopy with a fiber optical reflection probe was applied as a process analytical technology tool for the continuous quantitative in-line monitoring of pharmaceutical powder mixing processes in a bladed mixer. Two powders, acetyl salicylic acid as an active pharmaceutical ingredient (API) and alpha-lactose monohydrate as an excipient were characterized in advance in terms of shear cell tests, flowability tests and particle-size determination to deduce flow properties of the powders. For the quantitative monitoring of the API content, two predictive models were developed with partial-least-squares calibration based on off-line calibration. On the basis of these predictive models, powder agitation and mixing times until blend uniformity were quantitatively monitored. Mixing experiments with systematically varied filling levels and filling protocols showed a strong variation in mixing, but eventually yielded uniform powder blend. Simulation results from the literature were linked to our experimental findings in order to identify and elucidate the effects of convective and diffusive mixing. In accordance to the international conference on harmonization acceptance level of 5% for the nominal API content, UV/Vis reference measurements were performed to verify the blend uniformity as predicted by the NIR measurements. (C) 2010 Published by Elsevier B.V.
引用
收藏
页码:87 / 96
页数:10
相关论文
共 50 条
  • [21] Implanted near-infrared spectroscopy for cardiac monitoring
    Bhunia, Sourav K.
    Cinbis, Can
    OPTICAL TOMOGRAPHY AND SPECTROSCOPY OF TISSUE IX, 2011, 7896
  • [22] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    University of Calgary, Experimental Imaging Centre, Faculty of Medicine, 3330 Hospital Drive NW, Calgary, AB T2N 4N1, Canada
    不详
    不详
    不详
    不详
    J Biomed Opt, 2008, 6
  • [23] Monitoring angiogenesis noninvasively with near-infrared spectroscopy
    Dunn, Jeffrey F.
    Zhang, Qiong
    Wu, Ying
    Srinivasan, Sathyanarayanan
    Smith, Michael R.
    Shaw, R. Anthony
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (06)
  • [24] Cerebral oxygenation monitoring: near-infrared spectroscopy
    Tobias, Joseph D.
    EXPERT REVIEW OF MEDICAL DEVICES, 2006, 3 (02) : 235 - 243
  • [25] Near-infrared spectroscopy for monitoring muscle oxygenation
    Boushel, R
    Piantadosi, CA
    ACTA PHYSIOLOGICA SCANDINAVICA, 2000, 168 (04): : 615 - 622
  • [26] Usefulness of near-infrared spectroscopy in thrombectomy monitoring
    Thomas Ritzenthaler
    Tae-Hee Cho
    David Luis
    Yves Berthezene
    Norbert Nighoghossian
    Journal of Clinical Monitoring and Computing, 2015, 29 : 585 - 589
  • [27] Usefulness of near-infrared spectroscopy in thrombectomy monitoring
    Ritzenthaler, Thomas
    Cho, Tae-Hee
    Luis, David
    Berthezene, Yves
    Nighoghossian, Norbert
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2015, 29 (05) : 585 - 589
  • [28] Near-infrared spectroscopy for monitoring starch hydrolysis
    Chung, H
    Arnold, MA
    APPLIED SPECTROSCOPY, 2000, 54 (02) : 277 - 283
  • [29] Near-infrared spectroscopy for in situ monitoring of geoenvironment
    Ghandehari, Masoud
    Kostarelos, Konstantinos
    Cheng, Kai-Chung
    Vimer, Cristian
    Yoon, Sungho
    JOURNAL OF GEOTECHNICAL AND GEOENVIRONMENTAL ENGINEERING, 2008, 134 (04) : 487 - 496
  • [30] Near-infrared Spectroscopy Monitoring for Compartment Syndrome
    Smith, Emily K.
    Smith, Emily K.
    Austin, Ashley V.
    Freedman, Brett A.
    Shuler, Michael S.
    TECHNIQUES IN ORTHOPAEDICS, 2012, 27 (01) : 15 - 21