Using ISO/TS 20914:2019 to calculate the measurement uncertainty of immunosuppressive drugs in a clinical laboratory

被引:1
|
作者
Grote-Koska, Denis [1 ]
Brand, Korbinian [1 ]
机构
[1] Hannover Med Sch, Inst Clin Chem, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Measurement uncertainty; ciclosporin; everolimus; sirolimus; tacrolimus; immunosuppressants; ISO; TS; 20914; quality control; LC-MS; MS;
D O I
10.1080/00365513.2020.1731849
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
According to the standard ISO 15189 clinical routine laboratories shall estimate measurement uncertainty (MU) of patient results of their provided measurands. Up to now there was no accepted description on how to perform. Recently, the ISO technical standard ISO/TS 20914 was published giving a practical guide for uncertainty estimation. The immunosuppressive drugs Everolimus, Ciclosporin, Sirolimus and Tacrolimus have narrow therapeutic windows. Hence, their MU should be considered for deducing clinical decisions. Here, a pathway is presented in detail on how to estimate MU measuring immunosuppressants using a widespread CE certified assay via LC-MS/MS technology. Namely, the expanded measurement uncertainties are from 13% to 27% depending on analyte and concentration. The calculation based on n > 2000 measurements each of four control levels within one year. Lower uncertainties were observed if the material was native pooled blood (13% to 17%, n > 300 measurements, one year).
引用
收藏
页码:309 / 312
页数:4
相关论文
共 50 条
  • [1] ISO/TS 20914:2019-a critical commentary
    Farrance, Ian
    Frenkel, Robert
    Badrick, Tony
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2020, 58 (08) : 1182 - 1190
  • [2] Measurement uncertainty in clinical chemistry: ISO 20914 versus nordtest or intermediate precision versus bias
    Nurlu, Nilhan
    Cat, Abdulkadir
    Ucar, Kamil Taha
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 2024, 84 (03): : 147 - 153
  • [3] An outline of measurement uncertainty of total protein in urine estimated according to the ISO Technical Specification 20914
    Borrillo, Francesca
    Panteghini, Mauro
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (08) : e175 - e177
  • [4] MEASUREMENT UNCERTAINTY FOR ROUTINE MEASUREMENT PROCEDURES IN CLINICAL CHEMISTRY LABORATORY ACCREDITED ACCORDING TO ISO 15189
    Flegar-Mestric, Z.
    Surina, B.
    Perkov, S.
    Ozvald, I.
    Simonovic, B.
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 : S806 - S806
  • [5] Uncertainty of measurement in clinical laboratory sciences
    Fuentes-Arderiu, X
    [J]. CLINICAL CHEMISTRY, 2000, 46 (09) : 1437 - 1438
  • [7] Analytical performance specifications for measurement uncertainty in therapeutic monitoring of immunosuppressive drugs
    Cattaneo, Dario
    Panteghini, Mauro
    [J]. CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024, 62 (04) : e81 - e83
  • [8] IMPLEMENTATION OF A MEASUREMENT UNCERTAINTY GUIDELINE FOR ISO/IEC 17025 LABORATORY ASSESSORS
    da Jornada, Daniel Homrich
    ten Caten, Carla Schwengber
    [J]. XIX IMEKO WORLD CONGRESS: FUNDAMENTAL AND APPLIED METROLOGY, PROCEEDINGS, 2009, : 1447 - 1451
  • [9] Using the ISO guide to expression of uncertainty in measurement (GUM)
    Gogolak, Carl
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U2293 - U2293
  • [10] Uncertainty in Measurement: Procedures for Determining Uncertainty With Application to Clinical Laboratory Calculations
    Frenkel, Robert B.
    Farrance, Ian
    [J]. ADVANCES IN CLINICAL CHEMISTRY, VOL 84, 2018, 84 : 125 - 207