Fluid-structure interaction in abdominal aortic aneurysms: Structural and geometrical considerations

被引:4
|
作者
Mesri, Yaser [1 ,2 ]
Niazmand, Hamid [1 ,2 ]
Deyranlou, Amin [1 ,2 ]
Sadeghi, Mahmood Reza [3 ]
机构
[1] Ferdowsi Univ Mashhad, Dept Mech Engn, Mashhad, Iran
[2] Ferdowsi Univ Mashhad, Res Ctr Biomed Engn, Mashhad, Iran
[3] Univ Isfahan, Dept Biomed Engn, Esfahan, Iran
来源
关键词
Abdominal aortic aneurysm; peak wall stress; fluid-structure interaction; asymmetry; material model; wall thickness; WALL STRESS; FLOW DYNAMICS; RUPTURE; MECHANICS; MODEL; BIOMECHANICS; SIMULATION; RISK; FSI;
D O I
10.1142/S0129183115500382
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Rupture of the abdominal aortic aneurysm (AAA) is the result of the relatively complex interaction of blood hemodynamics and material behavior of arterial walls. In the present study, the cumulative effects of physiological parameters such as the directional growth, arterial wall properties (isotropy and anisotropy), iliac bifurcation and arterial wall thickness on prediction of wall stress in fully coupled fluid-structure interaction (FSI) analysis of five idealized AAA models have been investigated. In particular, the numerical model considers the heterogeneity of arterial wall and the iliac bifurcation, which allows the study of the geometric asymmetry due to the growth of the aneurysm into different directions. Results demonstrate that the blood pulsatile nature is responsible for emerging a time-dependent recirculation zone inside the aneurysm, which directly affects the stress distribution in aneurismal wall. Therefore, aneurysm deviation from the arterial axis, especially, in the lateral direction increases the wall stress in a relatively nonlinear fashion. Among the models analyzed in this investigation, the anisotropic material model that considers the wall thickness variations, greatly affects the wall stress values, while the stress distributions are less affected as compared to the uniform wall thickness models. In this regard, it is confirmed that wall stress predictions are more influenced by the appropriate structural model than the geometrical considerations such as the level of asymmetry and its curvature, growth direction and its extent.
引用
收藏
页数:18
相关论文
共 50 条
  • [31] Visualizing multiphysics, fluid-structure interaction phenomena in intracranial aneurysms
    Perdikaris, Paris
    Insley, Joseph A.
    Grinberg, Leopold
    Yu, Yue
    Papka, Michael E.
    Karniadakis, George Em.
    [J]. PARALLEL COMPUTING, 2016, 55 : 9 - 16
  • [32] Fluid-structure interaction simulation of aortic blood flow
    Crosetto, Paolo
    Reymond, Philippe
    Deparis, Simone
    Kontaxakis, Dimitrios
    Stergiopulos, Nikolaos
    Quarteroni, Alfio
    [J]. COMPUTERS & FLUIDS, 2011, 43 (01) : 46 - 57
  • [33] Fluid-structure interaction (FSI) analysis of stent-graft for aortic endovascular aneurysm repair (EVAR): Material and structural considerations
    Jayendiran, Raja
    Nour, Bakr
    Ruimi, Annie
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2018, 87 : 95 - 110
  • [34] An approach to the simulation of fluid-structure interaction in the aortic valve
    Carmody, CJ
    Burriesci, G
    Howard, IC
    Patterson, EA
    [J]. JOURNAL OF BIOMECHANICS, 2006, 39 (01) : 158 - 169
  • [35] Ultrasound-Based Fluid-Structure Interaction Modeling of Abdominal Aortic Aneurysms Incorporating Pre-Stress (vol 12, 717593, 2021)
    Fonken, Judith H. C.
    Maas, Esther J.
    Nievergeld, Arjet H. M.
    van Sambeek, Marc R. H. M.
    van de Vosse, Frans N.
    Lopata, Richard G. P.
    [J]. FRONTIERS IN PHYSIOLOGY, 2022, 13
  • [36] Comparative study of arterial wall models for numerical fluid-structure interaction simulation of aortic arch aneurysms
    Ferreira da Silva, Mario Luis
    Goncalves, Saulo de Freitas
    Huebner, Rudolf
    [J]. JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2022, 44 (05)
  • [37] Investigation of Rupture Risk of Thoracic Aortic Aneurysms via Fluid-Structure Interaction and Artificial Intelligence Method
    Koru, Murat
    Canbolat, Gokhan
    Daricik, Fatih
    Karahan, Oguz
    Etli, Mustafa
    Korkmaz, Ergun
    [J]. ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (11) : 14787 - 14802
  • [38] Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models
    Leung, James H.
    Wright, Andrew R.
    Cheshire, Nick
    Crane, Jeremy
    Thom, Simon A.
    Hughes, Alun D.
    Xu, Yun
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2006, 5 (1)
  • [39] Fluid structure interaction of patient specific abdominal aortic aneurysms: a comparison with solid stress models
    James H Leung
    Andrew R Wright
    Nick Cheshire
    Jeremy Crane
    Simon A Thom
    Alun D Hughes
    Yun Xu
    [J]. BioMedical Engineering OnLine, 5
  • [40] Fluid Structure Interaction Analysis in Abdominal Aortic Aneurysms: Influence of Diameter, Length, and Distal Neck
    Giuma, S. K. Badreddin
    Osman, Kahar
    Kadir, Mohammed Rafiq Abdul
    [J]. JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2013, 3 (04) : 514 - 522