Misclassification of OSA Severity With Automated Scoring of Home Sleep Recordings

被引:42
|
作者
Aurora, R. Nisha [1 ]
Swartz, Rachel [1 ]
Punjabi, Naresh M. [1 ,2 ]
机构
[1] Johns Hopkins Univ, Sch Med, Dept Med, Baltimore, MD 21224 USA
[2] Johns Hopkins Univ, Sch Med, Dept Epidemiol, Baltimore, MD 21224 USA
基金
美国国家卫生研究院;
关键词
DIAGNOSTIC-ACCURACY; APNEA; DEVICE; EPIDEMIOLOGY; CHANNEL; POLYSOMNOGRAPHY; TESTS;
D O I
10.1378/chest.14-0929
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
BACKGROUND: The advent of home sleep testing has allowed for the development of an ambulatory care model for OSA that most health-care providers can easily deploy. Although automated algorithms that accompany home sleep monitors can identify and classify disordered breathing events, it is unclear whether manual scoring followed by expert review of home sleep recordings is of any value. Thus, this study examined the agreement between automated and manual scoring of home sleep recordings. METHODS: Two type 3 monitors (ApneaLink Plus [ResMed] and Embletta [Embla Systems]) were examined in distinct study samples. Data from manual and automated scoring were available for 200 subjects. Two thresholds for oxygen desaturation (>= 3% and >= 4%) were used to define disordered breathing events. Agreement between manual and automated scoring was examined using Pearson correlation coefficients and Bland-Altman analyses. RESULTS: Automated scoring consistently underscored disordered breathing events compared with manual scoring for both sleep monitors irrespective of whether a >= 3% or >= 4% oxygen desaturation threshold was used to define the apnea-hypopnea index (AHI). For the ApneaLink Plus monitor, Bland-Altman analyses revealed an average AHI difference between manual and automated scoring of 6.1 (95% CI, 4.9-7.3) and 4.6 (95% CI, 3.5-5.6) events/h for the >= 3% and >= 4% oxygen desaturation thresholds, respectively. Similarly for the Embletta monitor, the average difference between manual and automated scoring was 5.3 (95% CI, 3.2-7.3) and 8.4 (95% CI, 7.2-9.6) events/h, respectively. CONCLUSIONS: Although agreement between automated and manual scoring of home sleep recordings varies based on the device used, modest agreement was observed between the two approaches. However, manual review of home sleep test recordings can decrease the misclassification of OSA severity, particularly for those with mild disease.
引用
收藏
页码:719 / 727
页数:9
相关论文
共 50 条
  • [1] Assessment of automated scoring of polysomnographic recordings in a population with suspected sleep-disordered breathing
    Pittman, SD
    MacDonald, MM
    Fogel, RB
    Malhotra, A
    Todros, K
    Levy, B
    Geva, AB
    White, DP
    [J]. SLEEP, 2004, 27 (07) : 1394 - 1403
  • [2] The Correlation of Computerized Scoring in Home Sleep Apnea Tests with Technician Visual Scoring for Assessing the Severity of Obstructive Sleep Apnea
    Hawco, Colton
    Bonthu, Amrita
    Pasek, Tristan
    Sarna, Kaylee
    Smolley, Laurence
    Hadeh, Anas
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (14)
  • [3] Home sleep apnea testing: comparison of manual and automated scoring across international sleep centers
    Magalang, Ulysses J.
    Johns, Jennica N.
    Wood, Katherine A.
    Mindel, Jesse W.
    Lima, Diane C.
    Bittencourt, Lia R.
    Chen, Ning-Hung
    Cistulli, Peter A.
    Gislason, Thorarinn
    Arnardottir, Erna S.
    Penzel, Thomas
    Tufik, Sergio
    Pack, Allan, I
    [J]. SLEEP AND BREATHING, 2019, 23 (01) : 25 - 31
  • [4] Home sleep apnea testing: comparison of manual and automated scoring across international sleep centers
    Ulysses J. Magalang
    Jennica N. Johns
    Katherine A. Wood
    Jesse W. Mindel
    Diane C. Lim
    Lia R. Bittencourt
    Ning-Hung Chen
    Peter A. Cistulli
    Thorarinn Gíslason
    Erna S. Arnardottir
    Thomas Penzel
    Sergio Tufik
    Allan I. Pack
    [J]. Sleep and Breathing, 2019, 23 : 25 - 31
  • [5] Home Sleep Tests for Obstructive Sleep Apnea (OSA)
    Kapoor, Mukesh
    Greenough, Glen
    [J]. JOURNAL OF THE AMERICAN BOARD OF FAMILY MEDICINE, 2015, 28 (04) : 504 - 509
  • [6] COMPUTERIZED METHOD FOR SCORING OF POLYGRAPHIC SLEEP RECORDINGS
    GATH, I
    BARON, E
    [J]. COMPUTER PROGRAMS IN BIOMEDICINE, 1980, 11 (03): : 217 - 223
  • [7] Autonomic Hypopnea Scoring And The Diagnostic Accuracy Of Home Sleep Recordings For Obstructive Sleep Apnea: Effect Of Negative Chronotropic Medication
    Lachapelle, P.
    Cascon, J. A.
    Pamidi, S.
    Lavigne, L.
    Kimoff, R. J.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2015, 191
  • [8] Completely unattended home sleep recordings
    Meadows, R
    Stanley, N
    Venn, S
    Hislop, J
    Arber, S
    [J]. SLEEP, 2005, 28 (04) : 526 - 526
  • [9] Impact of respiratory effort related arousals (RERAs) inclusion in scoring severity grading of obstructive sleep apnoea (OSA)
    O'Sullivan, R.
    Erigadoo, S.
    [J]. JOURNAL OF SLEEP RESEARCH, 2011, 20 : 59 - 59
  • [10] Automated Scoring of Obstructive Sleep Apnea and Hypopnea Events Using Short-Term Electrocardiogram Recordings
    Khandoker, Ahsan H.
    Gubbi, Jayavardhana
    Palaniswami, Marimuthu
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2009, 13 (06): : 1057 - 1067