The Correlation of Computerized Scoring in Home Sleep Apnea Tests with Technician Visual Scoring for Assessing the Severity of Obstructive Sleep Apnea

被引:0
|
作者
Hawco, Colton [1 ]
Bonthu, Amrita [2 ]
Pasek, Tristan [1 ]
Sarna, Kaylee [1 ]
Smolley, Laurence [1 ]
Hadeh, Anas [1 ]
机构
[1] Cleveland Clin Florida, Weston, FL 33331 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH 44106 USA
关键词
home sleep apnea test; obstructive sleep apnea; Polysmith; artificial intelligence; automated scoring; computer-assisted diagnosis; diagnostic accuracy; POLYSOMNOGRAPHY; VARIABILITY; ACCURACY;
D O I
10.3390/jcm13144204
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Obstructive sleep apnea (OSA) affects a significant proportion of the global population, with many having moderate or severe forms of the disease. Home Sleep Apnea Testing (HSAT) has become the most common method of diagnosing OSA, replacing in-lab polysomnography. Polysmith software Version 11 by Nihon Kohden allows for the automatic scoring of respiratory events. This study aimed to assess the validity of this technology. Study Objectives: The objective was to assess the accuracy of the Polysmith Software Automatic Scoring Algorithm of HSATs in comparison to that of sleep technicians. Methods: One hundred twenty HSATs were scored by both sleep technicians and Polysmith software. The measured values were the respiratory event index (REI), apneic events, and hypopneic events. Agreement between the two methods was reached by utilizing the Kruskal-Wallis test, Pearson correlation coefficient, and Bland-Altman plot, as well as sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: The correlation between the REI calculated by the software and technicians proved to be strong overall (r = 0.96, p < 0.0001). The mild OSA group had a moderate correlation (r = 0.45, p = 0.0129). The primary snoring, moderate OSA, and severe OSA groups showed stronger correlations (r = 0.69, p < 0.0001; r = 0.56, p = 0.012; r = 0.71, p < 0.0001). The analysis conducted across all groups demonstrated an average sensitivity of 81%, specificity of 94%, PPV of 82%, and NPV of 94%, with an overall accuracy of 81%. When combining the moderate and severe OSA groups into a single category, the sensitivity was 90%, specificity was 100%, PPV was 100%, and NPV was 91%. Conclusions: OSA can be reliably diagnosed from HSATs with the automated Polysmith software across all OSA disease severity groups, with higher levels of accuracy in moderate/severe OSA and lower levels of accuracy in mild OSA.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Home Sleep Tests for Obstructive Sleep Apnea (OSA)
    Kapoor, Mukesh
    Greenough, Glen
    JOURNAL OF THE AMERICAN BOARD OF FAMILY MEDICINE, 2015, 28 (04) : 504 - 509
  • [2] Explainable AI for EEG Biomarkers Identification in Obstructive Sleep Apnea Severity Scoring Task
    La Fisca, Luca
    Jennebauffe, Celiane
    Bruyneel, Marie
    Ris, Laurence
    Lefebvre, Laurent
    Siebert, Xavier
    Gosselin, Bernard
    2023 11TH INTERNATIONAL IEEE/EMBS CONFERENCE ON NEURAL ENGINEERING, NER, 2023,
  • [3] Home Sleep Apnea Testing for the Diagnosis of Obstructive Sleep Apnea
    Hoff, Scott
    Collop, Nancy
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2023, 329 (02): : 169 - 170
  • [4] USING CIRCUL® FOR ASSESSING OBSTRUCTIVE SLEEP APNEA SEVERITY
    Meira e Cruz, M.
    Chen, E.
    Zhou, Y.
    Shu, D.
    Zhou, C.
    Kryger, M.
    SLEEP MEDICINE, 2022, 100 : S305 - S306
  • [5] Automated sleep scoring and sleep apnea detection in children
    Baraglia, DP
    Berryman, MJ
    Coussens, SW
    Pamula, Y
    Kennedy, D
    Martin, AJ
    Abbott, D
    COMPLEX SYSTEMS-BK 2, 2006, 6039
  • [6] Problems in automatic sleep scoring applied to sleep apnea
    Penzel, T
    Kesper, K
    Gross, V
    Becker, HF
    Vogelmeier, C
    PROCEEDINGS OF THE 25TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-4: A NEW BEGINNING FOR HUMAN HEALTH, 2003, 25 : 358 - 361
  • [7] Correlation of Dyslipidemia and Inflammation With Obstructive Sleep Apnea Severity
    Popadic, Viseslav
    Brajkovic, Milica
    Klasnja, Slobodan
    Milic, Natasa
    Rajovic, Nina
    Lisulov, Danica Popovic
    Divac, Anica
    Ivankovic, Tatjana
    Manojlovic, Andrea
    Nikolic, Novica
    Memon, Lidija
    Brankovic, Marija
    Popovic, Maja
    Sekulic, Ana
    Macut, Jelica Bjekic
    Markovic, Olivera
    Djurasevic, Sinisa
    Stojkovic, Maja
    Todorovic, Zoran
    Zdravkovic, Marija
    FRONTIERS IN PHARMACOLOGY, 2022, 13
  • [8] Evaluation of apnea in the dog: A guidance on preclinical evaluations and correlation to clinical sleep apnea scoring
    Renninger, Jonathan
    DiPasquale, Jonathan
    Murphy, Dennis
    JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2016, 81 : 366 - 367
  • [9] Unreliability of automatic scoring of MESAM 4 in assessing patients with complicated obstructive sleep apnea syndrome
    Cirignotta, F
    Mondini, S
    Gerardi, R
    Mostacci, B
    Sancisi, E
    CHEST, 2001, 119 (05) : 1387 - 1392
  • [10] Discrepancy in polysomnography scoring for a patient with obstructive sleep apnea hypopnea syndrome
    Suzuki, M
    Saigusa, H
    Chiba, S
    Yagi, T
    Shibasaki, K
    Hayashi, M
    Suzuki, M
    Moriyama, K
    Kodera, K
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 2005, 206 (04): : 353 - 360