The Correlation of Computerized Scoring in Home Sleep Apnea Tests with Technician Visual Scoring for Assessing the Severity of Obstructive Sleep Apnea

被引:0
|
作者
Hawco, Colton [1 ]
Bonthu, Amrita [2 ]
Pasek, Tristan [1 ]
Sarna, Kaylee [1 ]
Smolley, Laurence [1 ]
Hadeh, Anas [1 ]
机构
[1] Cleveland Clin Florida, Weston, FL 33331 USA
[2] Case Western Reserve Univ, Sch Med, Cleveland, OH 44106 USA
关键词
home sleep apnea test; obstructive sleep apnea; Polysmith; artificial intelligence; automated scoring; computer-assisted diagnosis; diagnostic accuracy; POLYSOMNOGRAPHY; VARIABILITY; ACCURACY;
D O I
10.3390/jcm13144204
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Obstructive sleep apnea (OSA) affects a significant proportion of the global population, with many having moderate or severe forms of the disease. Home Sleep Apnea Testing (HSAT) has become the most common method of diagnosing OSA, replacing in-lab polysomnography. Polysmith software Version 11 by Nihon Kohden allows for the automatic scoring of respiratory events. This study aimed to assess the validity of this technology. Study Objectives: The objective was to assess the accuracy of the Polysmith Software Automatic Scoring Algorithm of HSATs in comparison to that of sleep technicians. Methods: One hundred twenty HSATs were scored by both sleep technicians and Polysmith software. The measured values were the respiratory event index (REI), apneic events, and hypopneic events. Agreement between the two methods was reached by utilizing the Kruskal-Wallis test, Pearson correlation coefficient, and Bland-Altman plot, as well as sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). Results: The correlation between the REI calculated by the software and technicians proved to be strong overall (r = 0.96, p < 0.0001). The mild OSA group had a moderate correlation (r = 0.45, p = 0.0129). The primary snoring, moderate OSA, and severe OSA groups showed stronger correlations (r = 0.69, p < 0.0001; r = 0.56, p = 0.012; r = 0.71, p < 0.0001). The analysis conducted across all groups demonstrated an average sensitivity of 81%, specificity of 94%, PPV of 82%, and NPV of 94%, with an overall accuracy of 81%. When combining the moderate and severe OSA groups into a single category, the sensitivity was 90%, specificity was 100%, PPV was 100%, and NPV was 91%. Conclusions: OSA can be reliably diagnosed from HSATs with the automated Polysmith software across all OSA disease severity groups, with higher levels of accuracy in moderate/severe OSA and lower levels of accuracy in mild OSA.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Pulse transit time for scoring subcortical arousal in infants with obstructive sleep apnea
    Rizzoli, Alessandra
    Urschitz, Michael S.
    Sautermeister, Judit
    Miano, Silvia
    Pagani, Jacopo
    Villa, Maria P.
    Poets, Christian F.
    SLEEP AND BREATHING, 2009, 13 (02) : 137 - 146
  • [32] Effect of prone position on apnea severity in obstructive sleep apnea
    Matsuzawa, Y
    Hayashi, S
    Yamaguchi, S
    Yoshikawa, S
    Okada, K
    Fujimoto, K
    Sekiguchi, M
    INTERNAL MEDICINE, 1995, 34 (12) : 1190 - 1193
  • [33] Differences between manual and automatic analysis in determining the severity of obstructive sleep apnea using home sleep apnea testing
    Labarca, Gonzalo
    Dreyse, Jorge
    Salas, Constanza
    Contreras, Andrea
    Nazar, Gonzalo
    Gaete, Maria I.
    Jorquera, Jorge
    SLEEP MEDICINE, 2018, 47 : 66 - 71
  • [34] AASM Scoring Manual 3: a step forward for advancing sleep care for patients with obstructive sleep apnea
    Malhotra, Raman K.
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2024, 20 (05): : 835 - 836
  • [35] SLEEP ONSET - SCORING CRITERIA IN PATIENTS WITH SLEEP-APNEA SYNDROME
    VALENCIAFLORES, M
    BLIWISE, DL
    GUILLEMINAULT, C
    CLINICAL ELECTROENCEPHALOGRAPHY, 1995, 26 (02): : 108 - 112
  • [36] Automatic scoring of drug-induced sleep endoscopy for obstructive sleep apnea using deep learning
    Hanif, Umaer
    Kiaer, Eva Kirkegaard
    Capasso, Robson
    Liu, Stanley Y.
    Mignot, Emmanuel J. M.
    Sorensen, Helge B. D.
    Jennum, Poul
    SLEEP MEDICINE, 2023, 102 : 19 - 29
  • [37] Relationship between the severity of obstructive sleep apnea and impaired glucose metabolism in patients with obstructive sleep apnea
    Tamura, Akira
    Kawano, Yoshiyuki
    Watanabe, Toru
    Kadota, Junichi
    RESPIRATORY MEDICINE, 2008, 102 (10) : 1412 - 1416
  • [38] Can arterial tonometry-based detection of obstructive sleep apnea be a promising alternative for home sleep apnea tests?
    Nanako Shiroshita
    Takatoshi Kasai
    Sleep and Biological Rhythms, 2025, 23 (2) : 99 - 100
  • [39] LIMITATIONS OF THE APNEA-HYPOPNEA INDEX FOR ASSESSING THE CLINICAL SEVERITY OF OBSTRUCTIVE SLEEP APNEA IN CHILDREN
    Chang, Y. -S.
    Lin, S. -H.
    Simonelli, A.
    Lee, G. S.
    Khatwa, U.
    SLEEP MEDICINE, 2017, 40 : E51 - E51
  • [40] Relationship between the severity of obstructive sleep apnea and impaired glucose metabolism in patients with obstructive sleep apnea
    Tamura, A.
    Kawano, Y.
    Miyamoto, K.
    Watanabe, T.
    Kadota, J.
    EUROPEAN HEART JOURNAL, 2008, 29 : 472 - 472