Effect of shed Configuration on AC Flashover Performance of Polluted Porcelain Insulators

被引:0
|
作者
Li, Yawei [1 ]
Zhang, Xinghai [1 ]
Yang, Xiaolei [2 ]
Bai, Huan [1 ]
Sun, Lei [3 ]
机构
[1] State Grid Sichuan Elect Power Co, Elect Power Res Inst, Chengdu, Peoples R China
[2] State Grid Chengdu Power Supply Co, Chengdu, Peoples R China
[3] Tsinghua Univ, Grad Sch Shenzhen, Shenzhen, Peoples R China
关键词
Shed configuration; Porcelain insulator; pollution flashover; AC;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The flashover of polluted insulator is one of the serious problems which should be taken into account in the design and coordination of high voltage insulation. In order to clarify the influence of umbrella shape configurations on the pollution flashover characteristics of AC suspension porcelain insulators, pollution flashover tests have been operated for 11 types of insulators with different umbrella shape configurations. The results indicate that the specific leakage distance increase with the enlargement of diameter and height of insulators, and the increasing severities are relevant to their umbrella shapes. The specific leakage distance of normal type insulators increase more significantly than that of outer-rib insulators with geometrical dimensions enlarging. With equal diameter or height, the specific leakage distance of normal type insulator is bigger than that of outer-rib insulator. And the leakage distance availabilities of normal insulators are superior to that of outer-rib insulator with the same geometrical dimensions. The test results also demonstrate that the contaminated flashover performances of insulators with bigger geometrical dimensions are better than that with smaller geometrical dimensions with the same umbrella shape, this is because that the bigger the geometrical dimensions, the longer the leakage length, and the contamination flashover voltage of certain pollution level is determined by both the umbrella shape configuration and the leakage length of insulator.
引用
收藏
页码:11 / 17
页数:7
相关论文
共 50 条
  • [31] Effect of test methods on AC flashover performance of iced porcelain insulator string
    Jiang, Xing-Liang
    Jiang, Yi-Ping
    Hu, Jian-Lin
    Zhang, Zhi-Jin
    [J]. Gaodianya Jishu/High Voltage Engineering, 2009, 35 (08): : 1869 - 1873
  • [32] Study on the Flashover Performance of Various Types of Insulators Polluted by Nitrates
    Zhang, Dongdong
    Zhang, Zhijin
    Jiang, Xingliang
    Yang, Zhongyi
    Liu, Youchao
    Bi, Maoqiang
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2017, 24 (01) : 167 - 174
  • [33] AC flashover performance of insulators covered with artificial ice
    Universite du Quebec a Chicoutimi, Chicoutimi, Canada
    [J]. IEEE Trans Power Delivery, 2 (1038-1045):
  • [34] AC FLASHOVER PERFORMANCE OF INSULATORS COVERED WITH ARTIFICIAL ICE
    FARZANEH, M
    DRAPEAU, JF
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1995, 10 (02) : 1038 - 1051
  • [35] Comparison on AC artificial pollution flashover performance and valid coefficient of creepage distance between porcelain and glass insulators
    Key Laboratory of High Voltage and Electrical New Technology, Chongqing University, Chongqing 400044, China
    [J]. Zhongguo Dianji Gongcheng Xuebao, 2007, 9 (6-10):
  • [36] Modeling of AC Flashover on Ice-covered Composite Insulators with Different Shed Configurations
    Shu, Lichun
    Wang, Shijing
    Jiang, Xingliang
    Hu, Qin
    Liang, Jian
    Yin, Pancheng
    Chen, Ji
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (06) : 2642 - 2651
  • [37] FLASHOVER CHARACTERISTICS OF POLLUTED INSULATORS.
    Chatterjee, N.
    [J]. Journal of the Institution of Engineers (India): Electrical Engineering Division, 1978, 58 (04): : 195 - 199
  • [38] The Influence of Natural Contamination on Pollution Flashover Voltage Waveform of Porcelain Insulators in Heavily Polluted Area
    Lan, Lei
    Zhang, Gongda
    Wang, Yu
    Wen, Xishan
    Wang, Wei
    Pei, Huan
    [J]. IEEE ACCESS, 2019, 7 : 121395 - 121406
  • [39] Influence of iced level of porcelain and glass insulators on DC flashover performance
    Wen, Xi-Shan
    Jiang, Ri-Kun
    Jiang, Xing-Liang
    Bi, Mao-Qiang
    Shen, Meng
    [J]. Gaodianya Jishu/High Voltage Engineering, 2010, 36 (03): : 565 - 571
  • [40] Experimental method for investigations on the influence of superimposed AC/DC field stress on the flashover performance of polluted outdoor insulators
    Wagner, A.
    Knauel, J.
    [J]. 2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 59 - 62