Comparison of one-, two-, and three-dimensional measurements of childhood brain tumors

被引:85
|
作者
Warren, KE
Patronas, N
Aikin, AA
Albert, PS
Balis, FM
机构
[1] NCI, Neurooncol Branch, Bethesda, MD 20892 USA
[2] NINDS, Bethesda, MD 20892 USA
[3] NCI, Pediat Oncol Branch, Bethesda, MD 20892 USA
[4] Ctr Clin, Dept Radiol, Bethesda, MD USA
[5] Ctr Clin, Biometr Res Branch, Bethesda, MD USA
关键词
D O I
10.1093/jnci/93.18.1401
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background. End points for assessing drug activity in brain tumors are determined by measuring the change in tumor size by magnetic resonance imaging (MRI) relative to a pretreatment or best-response scan. Traditionally, two-dimensional (2D) tumor measurements have been used, but one-dimensional (1D) measurements have recently been proposed as an alternative. Because software to estimate three-dimensional (3D) tumor volume from digitized MRI images is available, we compared all three methods of tumor measurement for childhood brain tumors and clinical outcome. Methods: Tumor size from 130 MRI scans from 32 patients (32 baseline and 98 follow-up scans, for a total of 130 scans; median, three scans per patient; range, two to 18 scans) was measured by each method. Tumor-response category (partial response, minor response, stable disease, or progressive disease) was determined from the percentage change in tumor size between the baseline or best-response scan and follow-up scans. Time to clinical progression was independently determined by chart review. All statistical tests were two-sided. Results: Concordances between ID and 2D, ID and 3D, and 2D and 3D were 83% (95% confidence interval [CI] = 67% to 99%), 61% (95 % CI = 47% to 75%), and 66% (95% CI = 52% to 80%), respectively, on follow-up scans. Concordances for ID and 3D and for 2D and 3D were statistically significantly lower than the concordance for ID and 2D (P<.001 and P =.003, respectively). Concordance among 1D, 2D, and 3D methods in detecting partial response was high; there was less concordance in classifying tumors in the minor response and progressive-disease categories. Median times to progression measured by the 1D, 2D, and 3D methods were 154, 105, and 112 days, respectively, compared with 114 days based on neurologic symptoms and signs (P =.09 for overall comparison). Conclusions: Detection of partial responses was not influenced by the measurement method, but estimating time to disease progression may be method dependent for childhood brain tumors.
引用
下载
收藏
页码:1401 / 1405
页数:5
相关论文
共 50 条
  • [41] Intrinsic spin Hall conductivity in one-, two-, and three-dimensional trivial and topological systems
    Matthes, L.
    Kuefner, S.
    Furthmueller, J.
    Bechstedt, F.
    PHYSICAL REVIEW B, 2016, 94 (08)
  • [42] One-, two- and three dimensional structures in thermotropic liquid crystals
    Diele, S
    Grande, S
    Kain, J
    Pelzl, G
    Weissflog, W
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2001, 362 : 111 - 132
  • [43] A comparison of two- and three-dimensional wave breaking
    Nepf, HM
    Wu, CH
    Chan, ES
    JOURNAL OF PHYSICAL OCEANOGRAPHY, 1998, 28 (07) : 1496 - 1510
  • [44] One- and two-dimensional measurements in the assessment of highly malignant brain tumors in children
    Windelberq, Mareike
    Warmuth-Metz, Monika
    Fleischhack, Gudrun
    Buchen, Stefanie
    Zimmermann, Martina
    Bach, Ferdinand
    Bode, Udo
    PEDIATRIC BLOOD & CANCER, 2007, 49 (04) : 521 - 521
  • [45] A Novel Method for Solving One-, Two- and Three-Dimensional Problems with Nonlinear Equation of the Poisson Type
    Reutskiy, S. Yu
    CMES-COMPUTER MODELING IN ENGINEERING & SCIENCES, 2012, 87 (04): : 355 - 386
  • [46] One-, two- and three-dimensional interlocked polymers based on hybrid inorganic-organic rotaxanes
    Lockyer, Selena J.
    Whitehead, George F. S.
    Timco, Grigore A.
    McInnes, Eric J. L.
    Winpenny, Richard E. P.
    CHEMICAL COMMUNICATIONS, 2024, 60 (74) : 10124 - 10127
  • [47] Hydrothermal preparation of nickel(II)/uranium(IV) fluorides with one-, two-, and three-dimensional topologies
    Bean, AC
    Sullens, TA
    Runde, W
    Albrecht-Schmitt, TE
    INORGANIC CHEMISTRY, 2003, 42 (08) : 2628 - 2633
  • [48] Correlation Of Left Ventricular Function Measured By One-, Two- And Three-dimensional Parameters In Elite Athletes
    Wang, Victor C.
    Mayer, Frank
    Appiah-Dwomoh, Edem K.
    Dorenkamp, Marc
    Bonaventura, Klaus
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 247 - 247
  • [49] Formation of one-, two-, and three-dimensional open-framework zinc phosphates in the presence of a tetramine
    Choudhury, A
    Natarajan, S
    Rao, CNR
    INORGANIC CHEMISTRY, 2000, 39 (19) : 4295 - 4304
  • [50] Si/SiGe Heterointerfaces in One-, Two-, and Three-Dimensional Nanostructures: Their Impact on SiGe Light Emission
    Lockwood, David J.
    Wu, Xiaohua
    Baribeau, Jean-Marc
    Mala, Selina A.
    Wang, Xiaolu
    Tsybeskov, Leonid
    FRONTIERS IN MATERIALS, 2016, 3