Post-operative monitoring of tissue transfers: Advantages using contrast enhanced ultrasound (CEUS) and contrast enhanced MRI (ceMRI) with dynamic perfusion analysis?

被引:21
|
作者
Lamby, P. [1 ]
Prantl, L. [1 ]
Fellner, C. [2 ,3 ]
Geis, S. [1 ]
Jung, E. M. [2 ,3 ]
机构
[1] Univ Hosp Regensburg, Ctr Plast Hand & Reconstruct Surg, D-93053 Regensburg, Germany
[2] Univ Hosp Regensburg, Inst Diagnost Radiol, D-93053 Regensburg, Germany
[3] Univ Hosp Regensburg, Interdisciplinary Ultrasound Dept, D-93053 Regensburg, Germany
关键词
Plastic surgery; tissue flaps; MRI; ceMRI; GD-DTPA; contrast enhanced ultrasound; CEUS; Sonovue; microcirculation; HIGH-RESOLUTION ULTRASOUND; RECONSTRUCTIVE SURGERY; HARMONIC ULTRASOUND; VASCULAR INTEGRITY; FREE FLAPS; MICROCIRCULATION; ANGIOGRAPHY; SUBTRACTION; SONOGRAPHY; AGENTS;
D O I
10.3233/CH-2011-1405
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The immediate evaluation of microvascular tissue flaps with respect to microcirculation after transplantation is crucial for optimal monitoring and outcome. The purpose of our investigation was to evaluate the clinical value of contrast-enhanced ultrasound (CEUS) and contrast-enhanced MRI (ceMRI) for monitoring the integrity of tissue flaps in plastic surgery. Methods: To this end, we investigated 10 patients (47 +/- 16 a) between postoperative day 7 and 14 who underwent flap surgery in order to cover tissue defects in various body regions. For CEUS we utilized the GE LOGIQ E9 (R) equipped with a linear transducer (6-9 MHz). After application of 2.4 ml SonoVue (R), the tissue perfusion was detected in Low MI-Technique (MI < 0.2). The perfusion curves were quantitatively analyzed using digital video sequences (QONTRAST (R), Bracco, Italy) regarding peak % and relative blood flow (RBF). Furthermore, we investigated all tissue flaps using contrast-enhanced MRI (Magnetom Symphony TIM (R), Siemens) with a 3D-VIBE sequence and a time resolution of 7s. Thus, the transplants were completely captured in all cases. As perfusion parameters, the positive enhancement integral (PEI) as well as the maximum intensity projection time (MIP-time) were collected. For comparison of both applications, all parameters were displayed in color-coded resolution and analyzed by three independent readers. Depending on the flap thickness, 1-3 regions of interest (ROI) were investigated. Each ROI measured 1 x 3 cm. Results: The subcutaneous ROI-1 showed a significantly lower rating regarding RBF in the ceMRI compared to CEUS (Mann-Whitney Rank-Sum test, p < 0.05). ROI-2 and -3 did not show any significant differences between the two applications. The frequency distribution showed good accordance in both modalities. Both imaging techniques detected 1 partial flap necrosis within the random area of cutaneous and subcutaneous layers, 1 hematoma as well as 1 insufficient perfusion over all tissue layers. After subsequent reoperation, graft loss could be prevented. Conclusion: At present, both technologies provide an optimal assessment of perfusion in cutaneous, subcutaneous and muscle tissue layers, whereby the detection of fatty tissue perfusion is currently more easily detected using CEUS compared to ceMRI.
引用
收藏
页码:105 / 117
页数:13
相关论文
共 50 条
  • [41] Pulmonary perfusion imaging in the rodent lung using dynamic contrast-enhanced MRI
    Mistry, Nilesh N.
    Pollaro, James
    Song, Jiayu
    De Lin, Ming
    Johnson, G. Allan
    MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (02) : 289 - 297
  • [42] Texture analysis of lesion perfusion volumes in dynamic contrast-enhanced breast MRI
    Lee, Sang Ho
    Kim, Jong Hyo
    Park, Jeong Seon
    Chang, Jung Min
    Park, Sang Joon
    Jung, Yun Sub
    Tak, Sungho
    Moon, Woo Kyung
    2008 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1-4, 2008, : 1545 - +
  • [43] MEASURING ABSOLUTE BLOOD PERFUSION IN MICE USING DYNAMIC CONTRAST-ENHANCED ULTRASOUND
    Shirinifard, Abbas
    Thiagarajan, Suresh
    Johnson, Melissa D.
    Calabrese, Christopher
    Sablauer, Andras
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (08): : 1628 - 1638
  • [44] Quantitative assessment of pulmonary perfusion with dynamic contrast-enhanced MRI
    Hatabu, H
    Tadamura, E
    Levin, DL
    Chen, Q
    Li, W
    Kim, D
    Prasad, PV
    Edelman, RR
    MAGNETIC RESONANCE IN MEDICINE, 1999, 42 (06) : 1033 - 1038
  • [45] Acral fibromyxoma: Findings on dynamic contrast-enhanced perfusion MRI
    Lacroix, Maxime
    Burns, Robert
    Campagna, Raphael
    Larousserie, Frederique
    Drape, Jean-Luc
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2022, 103 (01) : 59 - 61
  • [46] Hepatocellular Carcinoma: Perfusion Quantification With Dynamic Contrast-Enhanced MRI
    Taouli, Bachir
    Johnson, R. Scott
    Hajdu, Cristina H.
    Oei, Marcel T. H.
    Merad, Miriam
    Yee, Herman
    Rusinek, Henry
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (04) : 795 - 800
  • [47] Evaluation of lung tumor perfusion by dynamic contrast-enhanced MRI
    Pauls, Sandra
    Mottaghy, Felix M.
    Schmidt, Stefan A.
    Krueger, Stefan
    Moeller, Peter
    Brambs, Hans-Juergen
    Wunderlich, Arthur
    MAGNETIC RESONANCE IMAGING, 2008, 26 (10) : 1334 - 1341
  • [48] Assessment of carotid plaque perfusion and ulceration with dynamic contrast enhanced ultrasound
    Thapar, A.
    Zheng, Y.
    Dharmarajah, B.
    Averkiou, M.
    Shalhoub, J.
    Davies, A. H.
    Leen, E. L. S.
    INTERNATIONAL JOURNAL OF STROKE, 2012, 7 : 60 - 60
  • [49] Contrast Agent Quantification by Using Spatial Information in Dynamic Contrast Enhanced MRI
    Wang, Jianfeng
    Garpebring, Anders
    Brynolfsson, Patrik
    Yu, Jun
    FRONTIERS IN SIGNAL PROCESSING, 2021, 1
  • [50] ANALYSIS OF ERECTILE TISSUE CONTRAST ENHANCEMENT IN THE RAT CAVERNOUS NERVE INJURY MODEL USING DYNAMIC CONTRAST ENHANCED (DCE) MRI
    Tal, R.
    Bennett, N. E.
    Winkelman, D.
    Koutcher, J. A.
    Mulhall, J. P.
    JOURNAL OF SEXUAL MEDICINE, 2010, 7 : 156 - 156