Dosimetric Comparison of 3-Dimensional Conformal and Intensity-Modulated Radiotherapy Planning Techniques in Breast Cancer

被引:0
|
作者
Sirin Ozdemir, Beyza [1 ]
Kirecci, Orkun [2 ]
机构
[1] Akdeniz Univ, Dept Radiat Oncol, Fac Med, Antalya, Turkey
[2] Univ Hlth Sci, Tepecik Training & Res Hosp, Dept Nucl Med, Izmir, Turkey
来源
关键词
Radiotherapy; Breast cancer; 3DCRT; IMRT; Homogeneity index; CONTRALATERAL BREAST; CHEST-WALL; IMRT;
D O I
10.4999/uhod.193609
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Considering the high rates of long-term survival in breast cancer patients, it is crucial to determine the most appropriate RT technique in order to prevent RT-related heart and lung damage and other complications that may adversely affect quality of life. In this study, we aimed to detect the superior radiotherapy technique in patients with breast cancer in terms of the target volumes and the organ at risk (OAR). We included 20 breast cancer patients who were applied modified radical mastectomy. Two different treatment plans (IMRT and 3DCRT) were prepared for each patient. Chest wall, supraclavicular, axillary and/or mammaria interna lymphatic regions were contoured as clinical target volume (CTV). For planning target volume (PTV), 0.5 cm was added to CTV (post margin; 0.3 cm). The doses of the target volumes and the OAR volumes (contralateral breast, heart, ipsilateral lung), the homogeneity index (HI) were compared. For the heart, the contralateral breast, the ipsilateral lung, Dmean and V25, Dmean and Dmax, D5 and D20 were evaluated, respectively. In addition, D2, D98, D95 ve Dmean were investigated for the PTV Mann Whitney test was used for statistical analysis and p< 0.05 was considered significant. IMRT technique was superior to the 3DCRT in terms of the PTV the OAR volumes and the HI. However, irradiated contralateral breast volume was less in the 3DCRT technique.
引用
收藏
页码:191 / 197
页数:7
相关论文
共 50 条
  • [41] 3D-CONFORMAL VERSUS INTENSITY-MODULATED POSTOPERATIVE RADIOTHERAPY OF VAGINAL VAULT: A DOSIMETRIC COMPARISON
    Cilla, Savino
    Macchia, Gabriella
    Digesu, Cinzia
    Deodato, Francesco
    Romanella, Michele
    Ferrandina, Gabriella
    Padula, Gilbert D. A.
    Picardi, Vincenzo
    Scambia, Giovanni
    Piermattei, Angelo
    Morganti, Alessio Giuseppe
    [J]. MEDICAL DOSIMETRY, 2010, 35 (02) : 135 - 142
  • [42] 3D CONFORMAL VERSUS INTENSITY-MODULATED RADIOTHERAPY IN POST PROSTATECTOMY PATIENTS: A DOSIMETRIC COMPARISON
    Martin, Giuseppe
    Totaro, Giuseppe
    Verga, Enrico
    De Chiara, Vincenzo
    Morrone, Paolo
    Cicalese, Anna Rita
    Falco, Maria Daniela
    [J]. ANTICANCER RESEARCH, 2011, 31 (05) : 1877 - 1878
  • [43] Conformal and intensity-modulated radiotherapy for cervical cancer
    Taylor, A.
    Powell, M. E. B.
    [J]. CLINICAL ONCOLOGY, 2008, 20 (06) : 417 - 425
  • [44] Dosimetric comparison of three-dimensional conformal radiotherapy and static and dynamic intensity-modulated radiotherapy for the treatment of early-stage glottic cancer
    Inan, Gokcen
    Gul, Osman Vefa
    [J]. JOURNAL OF RADIATION ONCOLOGY, 2020, 9 (3-4) : 165 - 172
  • [45] Comparison of conformal radiotherapy, intensity-modulated radiotherapy and tomotherapy irradiation techniques in prostate cancers
    Tugrul, Taylan
    Olacak, Nezahat
    Koylu, Murat
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2019, 18 (03) : 276 - 279
  • [46] Dosimetric comparison of helical tomotherapy and intensity-modulated radiotherapy in cervical cancer
    Liu, J.
    Zhu, L.
    Li, S.
    Gao, S.
    Yan, J.
    Xie, L.
    Hou, Z.
    Zhou, X.
    Liu, B.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S1005 - S1006
  • [47] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    Thibouw, David
    Truc, Gilles
    Bertaut, Aurelie
    Chevalier, Cedric
    Aubignac, Leone
    Mirjolet, Celine
    [J]. JOURNAL OF NEURO-ONCOLOGY, 2018, 137 (02) : 429 - 438
  • [48] Clinical and dosimetric study of radiotherapy for glioblastoma: three-dimensional conformal radiotherapy versus intensity-modulated radiotherapy
    David Thibouw
    Gilles Truc
    Aurélie Bertaut
    Cédric Chevalier
    Léone Aubignac
    Céline Mirjolet
    [J]. Journal of Neuro-Oncology, 2018, 137 : 429 - 438
  • [49] Toxicity and Outcome of Intensity-Modulated Radiotherapy versus 3-Dimensional Conformal Radiotherapy for Oropharyngeal Cancer: A Matched-Pair Analysis
    Al-Mamgani, Abrahim
    Van Rooij, Peter
    Tans, Lisa
    Teguh, David N.
    Levendag, Peter C.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2013, 12 (02) : 123 - 130
  • [50] Breast-conserving radiotherapy with simultaneous integrated boost; field-in-field three-dimensional conformal radiotherapy versus inverse intensity-modulated radiotherapy - A dosimetric comparison: Do we need intensity-modulated radiotherapy?
    Joseph, Bindhu
    Farooq, Nisma
    Kumar, Sabari
    Vijay, C. R.
    Puthur, Kurian J.
    Ramesh, C.
    Lokesh, Vishwanath
    [J]. SOUTH ASIAN JOURNAL OF CANCER, 2018, 7 (03) : 163 - 166