DIAGNOSIS AND MONITORING OF PAROXYSMAL NOCTURNAL HEMOGLOBINURIA BY MULTIPARAMETER FLOW CYTOMETRY. OPTIMIZATION OF PROTOCOLS BASED ON CD59, CD55 AND FLAER

被引:0
|
作者
Beneit, P. [1 ]
Mauricio, A. [1 ]
Tarin, F. [1 ]
Garcia, M. [1 ]
Mora, E. [1 ]
Fernandez, M. [1 ]
Salazar, S. [1 ]
De Paz, F. [1 ]
Verdu, J. [1 ]
Borrego, D. [2 ]
Fernandez, J. [3 ]
Acedo, A. [4 ]
Verdu, J. [1 ]
机构
[1] Hosp Gen Univ Alicante, Hematol, Alicante, Spain
[2] Hosp Gen Univ Elda, Hematol, Alicante, Spain
[3] Hosp Univ San Juan, Hematol, Alicante, Spain
[4] Hosp Vega Baja, Hematol, Alicante, Spain
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
B1431
引用
收藏
页码:575 / 576
页数:2
相关论文
共 50 条
  • [31] Comparison between two flow Cytometry methods for the immunophenotypic analysis of CD55 and CD59 on major peripheral blood all populations
    Campo, MMH
    Martín-Ayuso, M
    Almeida, J
    Lopez, A
    de Matos, AO
    CYTOMETRY, 2002, : 119 - 119
  • [32] DIAGNOSIS OF PAROXYSMAL-NOCTURNAL HEMOGLOBINURIA BY PHENOTYPIC ANALYSIS OF ERYTHROCYTES USING 2-COLOR FLOW-CYTOMETRY WITH MONOCLONAL-ANTIBODIES TO DAF AND CD59/MACIF
    SHICHISHIMA, T
    TERASAWA, T
    SAITOH, Y
    HASHIMOTO, C
    OHTO, H
    MARUYAMA, Y
    BRITISH JOURNAL OF HAEMATOLOGY, 1993, 85 (02) : 378 - 386
  • [33] 外周血粒细胞CD55,CD59和FLAER检测在贫血及PNH诊断中的意义
    杨柯
    郭晓宇
    欧剑锋
    白海
    潘耀柱
    现代检验医学杂志, 2017, 32 (03) : 6 - 10
  • [34] Comparative analysis of different flow cytometry-based immunophenotypic methods for the analysis of CD59 and CD55 expression on major peripheral blood cell subsets
    Hernández-Campo, PM
    Martín-Ayaso, M
    Almeida, J
    López, A
    Orfao, A
    CYTOMETRY, 2002, 50 (03): : 191 - 201
  • [35] PAROXYSMAL-NOCTURNAL HEMOGLOBINURIA DUE TO HEREDITARY NUCLEOTIDE DELECTION IN THE HRF20 (CD59) GENE
    MOTOYAMA, N
    OKADA, N
    YAMASHINA, M
    OKADA, H
    EUROPEAN JOURNAL OF IMMUNOLOGY, 1992, 22 (10) : 2669 - 2673
  • [36] Use of complement regulators, CD35, CD46, CD55, and CD59, on leukocytes as markers for diagnosis of viral and bacterial infections
    Nuutila, Jari
    Jalava-Karvinen, Paivi
    Hohenthal, Ulla
    Kotilainen, Pirkko
    Pelliniemi, Tarja-Terttu
    Nikoskelainen, Jukka
    Lilius, Esa-Matti
    HUMAN IMMUNOLOGY, 2013, 74 (05) : 522 - 530
  • [37] MULTIPARAMETER FLAER-BASED WBC ASSAY VERSUS CD59 EXPRESSION ON RBCS IN THE PRIMARY SCREENING OF PNH CLONES
    Anderson, Tanya
    Kuek, Nancy
    Barth, David
    Keeney, Michael
    Sutherland, Robert
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2008, 74B (06) : 364 - 364
  • [38] Paroxysmal nocturnal hemoglobinuria (PNH) and primary p.Cys89Tyr mutation in CD59: Differences and similarities
    Mevorach, Dror
    MOLECULAR IMMUNOLOGY, 2015, 67 (01) : 51 - 55
  • [39] Utility of FLAER and CD157 in a five-color single-tube high sensitivity assay, for diagnosis of Paroxysmal Nocturnal Hemoglobinuria (PNH)-A standalone flow cytometry laboratory experience
    Seth, Neha
    Mahajan, Vidisha
    Kedia, Shweta
    Sutar, Archana
    Sehgal, Kunal
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2021, 43 (02) : 259 - 265
  • [40] UTILITY OF CD157 IN A FLAER BASED SINGLE TUBE FIVE COLOR COMBINATION FOR SCREENING OF PAROXYSMAL NOCTURNAL HEMOGLOBINURIA CLONE
    Rahman, K.
    Gupta, R.
    Harankhedkar, S.
    Gupta, T.
    Sarkar, M.
    Nityanand, S.
    HAEMATOLOGICA, 2017, 102 : 403 - 403