Optimization of a measuring set-up for the kinematics detection of electromagnetic fields

被引:1
|
作者
Bellia, P [1 ]
Carrubba, S [1 ]
Falciglia, F [1 ]
Gulino, M [1 ]
Triglia, A [1 ]
Mussumeci, G [1 ]
机构
[1] Univ Catania, DMFCI, I-95125 Catania, Italy
关键词
monitoring of electromagnetic field; kinematics measures;
D O I
10.1109/ICSMC2.2003.1429058
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Large band instruments and GPS-GIS (Global Position System - Geographic Information Systems) systems installed on a vehicle in motion are used to measure the electromagnetic field (EMF) present at the ground in a kinematics way. This procedure allows to constantly monitor a wide part of the territory very quickly and cutting the prises. Using a vehicle in motion equipped with a GPS-GIS system synchronized with an electric field probe, it is possible to measure continuously at the same time the position of the probe and the correspondent EMF value. However, many factors as vehicle presence, probe position and field frequency affect the results. To measure high frequency EMF, we suggest to use a metallic shield with known geometric and dielectric properties. This new set-up can be easily simulated and reproduced in laboratory. Comparing laboratory measurements and theoretical calculations it is possible to determine the suitable measurements conditions.
引用
收藏
页码:916 / 918
页数:3
相关论文
共 50 条
  • [21] PROBE AND COMPONENT SET-UP PLANNING FOR COORDINATE MEASURING MACHINES
    CORRIGALL, MJ
    BELL, R
    INTERNATIONAL JOURNAL OF COMPUTER INTEGRATED MANUFACTURING, 1991, 4 (01) : 34 - 44
  • [22] A NEW SET-UP FOR TOTAL REACTION CROSS SECTION MEASURING
    Sobolev, Yu. G.
    Ivanov, M. P.
    Kugler, A.
    Penionzhkevich, Yu. E.
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON EXOTIC NUCLEI (EXON 2012), 2012, : 431 - +
  • [23] SIMPLE SET-UP FOR MEASURING DURATION OF FLUORESCENCE LIFE BY SAMPLING
    RODIER, F
    ICOLE, MJ
    PHOTOCHEMISTRY AND PHOTOBIOLOGY, 1973, 17 (06) : 473 - 478
  • [24] SET-UP OF INJECTION MOLDS - SYSTEMATIC SET-UP OF INJECTION MOLDS
    KURTH, D
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1987, 95 (05): : ZM136 - ZM138
  • [25] SET-UP OF INJECTION MOLDS - SYSTEMATIC SET-UP OF INJECTION MOLDS
    KURTH, D
    KUNSTSTOFFE-GERMAN PLASTICS, 1987, 77 (07): : ZM136 - ZM138
  • [26] Detection of optical photons with the Timepix in an HPD set-up
    Gebert, Ulrike
    Ruegheimer, Tilman K.
    Michel, Thilo
    Anton, Gisela
    Seguinot, Jacques
    Joram, Christian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 623 (01): : 288 - 290
  • [27] Marking the set-up
    Curtin, Joseph
    STRAD, 2012, 123 (1466): : 68 - 70
  • [28] NEW EXPERIMENTAL SET-UP FOR THE DETECTION OF DEBROGLIE WAVES
    GARUCCIO, A
    RAPISARDA, V
    VIGIER, JP
    PHYSICS LETTERS A, 1982, 90 (1-2) : 17 - 19
  • [30] EXAM SET-UP
    LANSDOWN, R
    NEW SOCIETY, 1985, 74 (1196): : 388 - 388