Beam test results for single- and double-sided irradiated silicon detector prototypes of the CMS Central Detector

被引:2
|
作者
Angarano, MM
Azzi, P
Bacchetta, N
Bartalini, P
Bilei, GM
Bisello, D
Boemi, D
Busetto, G
Castro, A
Checcucci, B
Creanza, D
de Palma, M
Fiore, L
Loreti, M
Martignon, G
My, S
Raso, G
Santocchia, A
Selvaggi, G
Servoli, L
Silvestris, L
Stavitski, I
Tempesta, P
机构
[1] Univ Bari, Dipartmento Fis, I-70126 Bari, Italy
[2] Ist Nazl Fis Nucl, I-70126 Bari, Italy
[3] Univ Padua, I-35100 Padua, Italy
[4] Ist Nazl Fis Nucl, Padua, Italy
[5] Univ Perugia, I-06100 Perugia, Italy
[6] Ist Nazl Fis Nucl, I-06100 Perugia, Italy
[7] Univ Catania, I-95124 Catania, Italy
[8] Ist Nazl Fis Nucl, I-95129 Catania, Italy
关键词
CMS tracking; silicon detectors; radiation hardness;
D O I
10.1016/S0168-9002(98)00082-5
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We present the results of two beam tests performed in July and September 1996 at CERN in order to study the behaviour of irradiated single- and double-sided silicon detectors from different manufacturers. All detectors had been irradiated with neutrons, up to a maximum fluence of 3.6 x 10(13) cm(-2), and had reached type inversion. Signal-to-noise ratio, resolution and efficiency have been studied for different values of detectors bias voltage, operation temperature (ranging from - 10 degrees C to f 20 degrees C) and read-out pitch and, in some case, for different incidence angle of the incoming particle. The results are promising, since no dramatic deterioration of detector performances has been observed. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
下载
收藏
页码:135 / 138
页数:4
相关论文
共 50 条
  • [1] Beam test results for single- and double-sided irradiated silicon detector prototypes of the CMS central detector
    Angarano, M.M.
    Azzi, P.
    Bacchetta, N.
    Bartalini, P.
    Bilei, G.M.
    Bisello, D.
    Boemi, D.
    Busetto, G.
    Castro, A.
    Checcucci, B.
    Creanza, D.
    de Palma, M.
    Fiore, L.
    Loreti, M.
    Martignon, G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 409 (1-3): : 135 - 138
  • [2] Beam test results for single-and double-sided silicon detector prototypes of the CMS central detector
    Adriani, O
    Babucci, E
    Bacchetta, N
    Bagliesi, G
    Bartalini, P
    Basti, A
    Bilei, GM
    Boemi, D
    Borrello, L
    Castaldi, R
    Castellini, G
    Catacchini, E
    Cazzola, U
    Checcucci, B
    Civinini, C
    Creanza, D
    DAlessandro, R
    DePalma, M
    DellOrso, R
    DellaMarina, R
    Fiore, L
    Focardi, E
    Gabbanini, A
    Giassi, A
    Giraldo, A
    Gorn, L
    Loreti, M
    Maggi, G
    Mantovani, G
    Meschini, M
    Messineo, A
    My, S
    Parrini, G
    Pieri, M
    Raffaelli, F
    Raso, G
    Santocchia, A
    Selvaggi, G
    Servoli, L
    Silvestris, L
    Skassyrskaia, A
    Szoncso, F
    Tempesta, P
    Tesi, M
    Tonelli, G
    Vannini, C
    Verdini, PG
    Wheadon, R
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 396 (1-2): : 76 - 92
  • [3] Development and test of double-sided silicon strip detector
    Sun, Li-Jie
    Lin, Cheng-Jian
    Yang, Feng
    Guo, Zhao-Qiao
    Guo, Tian-Shu
    Xu, Xin-Xing
    Bao, Peng-Fei
    Yang, Lei
    Jia, Hui-Ming
    Ma, Nan-Ru
    Zhang, Huan-Qiao
    Liu, Zu-Hua
    Xia, Qing-Liang
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2015, 49 (02): : 336 - 342
  • [4] Heavily irradiated double-sided wedge silicon microstrip detector
    Universita di Firenze, Firenze, Italy
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1998, 409 (1-3): : 132 - 134
  • [5] Heavily irradiated double-sided wedge silicon microstrip detector
    Bruzzi, M
    Catacchini, E
    D'Alessandro, R
    Parrini, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 409 (1-3): : 132 - 134
  • [6] PERFORMANCE ON TEST BEAM OF THE L3 DOUBLE-SIDED SILICON MICROSTRIP DETECTOR
    ADAM, A
    ADRIANI, O
    AHLEN, S
    AMBROSI, G
    BABUCCI, E
    BASCHIROTTO, A
    BATTISTON, R
    BY, A
    BENCZE, GL
    BERTUCCI, B
    BIASINI, M
    BILEI, GM
    BOBBINK, GJ
    BOSETTI, M
    BROOKS, ML
    BUSENITZ, J
    BURGER, WJ
    CAMPS, C
    CARIA, M
    CASTELLINI, G
    CHECCUCCI, B
    CHEN, A
    COAN, TE
    COMMICHAU, V
    DIBITONTO, D
    DUINKER, P
    EASO, S
    EXTERMANN, P
    FIANDRINI, E
    GOUGAS, A
    HANGARTER, K
    HAUVILLER, C
    HERVE, A
    HU, G
    JOSA, I
    KAPUSTINSKI, JS
    KIM, D
    KINNISON, WW
    KRASTEV, VR
    LANDI, G
    LEBEAU, M
    LECOMTE, P
    LEE, DM
    LEISTE, R
    LIN, WT
    LOHMANN, W
    MARIN, A
    MASSETTI, R
    MILLS, GB
    NOWAK, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 348 (2-3): : 436 - 439
  • [7] Characterization of an irradiated double-sided silicon strip detector with fast binary readout electronics in a pion beam
    Unno, Y
    Kohriki, T
    Kondo, T
    Iwasaki, H
    Terada, S
    Takahata, M
    Tamura, N
    Maeohmichi, H
    Ohmoto, T
    Yoshikawa, M
    Ohyama, H
    Handa, T
    Iwata, Y
    Ohsugi, T
    Haber, C
    Siegrist, J
    Spieler, H
    Dubbs, T
    Grillo, A
    Hubbard, B
    Kashigin, S
    Kroeger, W
    Noble, K
    OShaughnessy, K
    Pulliam, T
    Rowe, WA
    Sadrozinski, HFW
    Seiden, A
    Spencer, E
    Webster, A
    Wichmann, R
    Wilder, M
    Takashima, R
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) : 1175 - 1179
  • [8] Characterization of an irradiated double-sided silicon strip detector with fast binary readout electronics in a pion beam
    KEK
    IEEE Trans Nucl Sci, 3 pt 2 (1175-1179):
  • [9] Test beam results of silicon drift detector prototypes for the ALICE experiment
    Nouais, D
    Bonvicini, V
    Busso, L
    Cerello, P
    Giubellino, P
    Gregorio, A
    Hernández-Montoya, R
    Idzik, M
    Kolojvari, A
    Mazza, G
    Montano, LM
    Nilsen, BS
    Petta, C
    Randazzo, N
    Rashevsky, A
    Reito, S
    Rivetti, A
    Tosello, F
    Trzaska, WH
    Vacchi, A
    NUCLEAR PHYSICS B-PROCEEDINGS SUPPLEMENTS, 1999, 78 : 252 - 258
  • [10] Test of a double-sided double-metal silicon microstrip detector with an ONO insulator
    Tsuboyama, T
    Haba, J
    Ikeda, H
    Iwasaki, H
    Matsuda, T
    Ozaki, H
    Tanaka, M
    Yamada, Y
    Saito, Y
    Akamine, K
    Inoue, M
    Yamanaka, J
    Kadoi, K
    Takano, R
    Kojima, Y
    Miyahara, S
    Kamiya, M
    1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, : 192 - 195