How does the geometry affect the internal biomechanics of a lumbar spine bi-segment finite element model? Consequences on the validation process

被引:83
|
作者
Noailly, Jerome
Wilke, Hans-Joachim
Planell, Josep A.
Lacroix, Damien
机构
[1] Univ Politecn Cataluna, Dept Mat Sci, Inst Bioengn Catalunya, E-08028 Barcelona, Spain
[2] Univ Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
关键词
finite-element modelling; stress distribution; geometric model; lumbar spine; validation;
D O I
10.1016/j.jbiomech.2006.11.021
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Numerical modelling can provide a thorough understanding of the mechanical influence on the spinal tissues and may offer explanations to mechanically linked pathologies. Such objective might be achieved only if the models are carefully validated. Sensitivity study must be performed in order to evaluate the influence of the approximations inherent to modelling. In this study, a new geometrically accurate L3-L5 lumbar spine bi-segmental finite-element model was acquired by modifying a previously existing model. The effect of changes in bone geometry, ligament fibres distribution, nucleus position and disc height was investigated in flexion and extension by comparison of the results obtained from the model before and after the geometrical update. Additional calculations were performed in axial rotation and lateral bending in order to compare the computed ranges of motion (ROM) with experimental results. It was found that the geometrical parameters affected the stress distribution and strain energy in the zygapophysial joints, the ligaments, and the intervertebral disc, changing qualitatively and quantitatively their relative role in resisting the imposed loads. The predicted ROM were generally in good agreement with the experimental results, independently of the geometrical changes. Hence, although the model update affected its internal biomechanics, no conclusions could be drawn from the experimental data about the validation of a particular geometry. Hence the validation of the lumbar spine model should be based on the relative role of its structural components and not only on its global mobility. (c) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2414 / 2425
页数:12
相关论文
共 30 条
  • [21] Validation efforts and flexibilities of an eight-year-old human juvenile lumbar spine using a threeaEurodimensional finite element model
    Jebaseelan, D. Davidson
    Jebaraj, Chidambaram
    Yoganandan, Narayan
    Rajasekaran, S.
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2010, 48 (12) : 1223 - 1231
  • [22] Does Lumbar Interbody Fusion Modality Affect the Occurrence of Complications in an Osteoporotic Spine Under Whole-Body Vibration? A Finite Element Study
    Zeng, Qiuhong
    Liao, Yi
    Pou, Kuokchon
    Chen, Qian
    Li, Yixuan
    Cai, Lulu
    Huang, Zhen
    Tang, Shujie
    WORLD NEUROSURGERY, 2023, 176 : E297 - E305
  • [23] Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5-C6 segment
    Clausen, JD
    Goel, VK
    Traynelis, VC
    Scifert, J
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) : 342 - 347
  • [24] Validation efforts and flexibilities of an eight-year-old human juvenile lumbar spine using a three‐dimensional finite element model
    D. Davidson Jebaseelan
    Chidambaram Jebaraj
    Narayan Yoganandan
    S. Rajasekaran
    Medical & Biological Engineering & Computing, 2010, 48 : 1223 - 1231
  • [25] Influence of loading cycle profile and frequency on a biomechanical parameter of a model of a balloon kyphoplasty-augmented lumbar spine segment: A finite element analysis study
    Li, Yuan
    Lewis, Gladius
    BIO-MEDICAL MATERIALS AND ENGINEERING, 2010, 20 (06) : 349 - 359
  • [26] How does prestrain in the tympanic membrane affect middle-ear function? A finite-element model study in rabbit
    Muyshondt, Pieter G. G.
    Dirckx, Joris J. J.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2022, 131
  • [27] Oblique lateral interbody fusion with internal fixations in the treatment for cross-segment degenerative lumbar spine disease (L2-3 and L4-5) finite element analysis
    Shuyi Zhang
    Yilong Zhang
    Licai Huang
    Shuao Zhang
    Chenshui Lu
    Zhengpeng Liu
    Chan Kang
    Zhao Wang
    Scientific Reports, 13 (1)
  • [28] Author Correction: Oblique lateral interbody fusion with internal fixations in the treatment for cross-segment degenerative lumbar spine disease (L2-3 and L4-5) finite element analysis
    Shuyi Zhang
    Yilong Zhang
    Licai Huang
    Shuao Zhang
    Chenshui Lu
    Zhengpeng Liu
    Chan Kang
    Zhao Wang
    Scientific Reports, 13
  • [29] Oblique lateral interbody fusion with internal fixations in the treatment for cross-segment degenerative lumbar spine disease (L2-3 and L4-5) finite element analysis (vol 13, 17116, 2023)
    Zhang, Shuyi
    Zhang, Yilong
    Huang, Licai
    Zhang, Shuao
    Lu, Chenshui
    Liu, Zhengpeng
    Kang, Chan
    Wang, Zhao
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [30] How does a three-dimensional continuum muscle model affect the kinematics and muscle strains of a finite element neck model compared to a discrete muscle model in rear-end, frontal, and lateral impacts
    Hedenstierna, Sofia
    Halldin, Peter
    SPINE, 2008, 33 (08) : E236 - E245