Digital Nullification of Visual Distortion to Quantify Metamorphopsia: A Pilot Study

被引:2
|
作者
Lifton, Jacob A. [1 ]
Moshfeghi, Andrew A. [2 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Los Angeles, CA USA
[2] Univ Southern Calif, Keck Sch Med, Dept Ophthalmol, USC Roski Eye Inst, Los Angeles, CA 90007 USA
来源
关键词
QUALITY-OF-LIFE; M-CHARTS; QUANTIFICATION; SURGERY; PHP;
D O I
10.3928/23258160-20191211-02
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND AND OBJECTIVE: To evaluate a novel digital method of metamorphopsia quantification in patients with symptomatic visual distortion as determined by M-CHARTS. PATIENTS AND METHODS: In this institutional review board-approved, prospective, cross-sectional observational study, subjects were presented with an objectively straight dotted line that bisects a central fixation point. The subjects digitally altered the line's contour until it appeared straight. Calculation of the area between the original objectively straight line presented to the subject and their newly manipulated line was performed to determine the manipulated area under the curve (M-AUC). RESULTS: Sixty-two percent of test targets were fully or significantly straightened by affected subjects. M-AUC was significantly correlated with M-CHARTS scores in both the horizontal (P <.001) and vertical (P =.05) orientations. CONCLUSIONS: The deformation of an objectively straight line by a subject with metamorphopsia may be a viable way of both quantifying and spatially characterizing visual distortions.
引用
收藏
页码:11 / 20
页数:10
相关论文
共 50 条
  • [21] Visual Morbidity in Stroke Survivors: A Pilot Study
    Nedumgattil, Arya R.
    Satyan, Sanitha
    Mohan, Madhukar
    Mathew, Jomal
    Menon, Ashok
    ANNALS OF INDIAN ACADEMY OF NEUROLOGY, 2022, 25 (06) : 1192 - 1194
  • [22] VISUAL CONSEQUENCES OF iPad USE: A PILOT STUDY
    Maducdoc, M.
    Crow, W.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2014, 62 (01) : 254 - 254
  • [23] A pilot study using "ROPtool" to quantify plus disease in retinopathy of prematurity - Reply
    Wallace, David K.
    Zhao, Zheen
    Freedman, Sharon F.
    JOURNAL OF AAPOS, 2007, 11 (06): : 631 - 631
  • [24] A Coding System to Quantify Powerful Actions in Soccer Match Play: A Pilot Study
    Murtagh, Conall F.
    Naughton, Robert J.
    McRobert, Allistair P.
    O'Boyle, Andrew
    Morgans, Ryland
    Drust, Barry
    Erskine, Robert M.
    RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2019, 90 (02) : 234 - 243
  • [25] Effect of static visual acuity on dynamic visual acuity: A pilot study
    Nakatsuka, Mieko
    Ueda, Tetsuo
    Nawa, Yoshiaki
    Yukawa, Eiichi
    Hara, Tokuko
    Hara, Yoshiaki
    PERCEPTUAL AND MOTOR SKILLS, 2006, 103 (01) : 160 - 164
  • [26] Digital breast tomosynthesis: A pilot observer study
    Good, Walter F.
    Abrams, Gordon S.
    Catullo, Victor J.
    Chough, Denise M.
    Ganott, Marie A.
    Hakim, Christiane M.
    Gur, David
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (04) : 865 - 869
  • [27] A pilot study of a digital drainage system in pneumothorax
    Tunnicliffe, Georgia
    Draper, Adrian
    BMJ OPEN RESPIRATORY RESEARCH, 2013, 1 (01):
  • [28] Digital dysfunctions in primary school: A pilot study
    Thorvaldsen, Steinar
    Egeberg, Gunstein
    Pettersen, Geir Olaf
    Vavik, Lars
    COMPUTERS & EDUCATION, 2011, 56 (01) : 312 - 319
  • [29] Comparison of analogue and digital PCIA, pilot study
    Weyns, M.
    Saldien, V
    ACTA ANAESTHESIOLOGICA BELGICA, 2020, 71 : 153 - 158
  • [30] Digital therapeutic improves visual acuity and encourages high adherence in amblyopic children in open-label pilot study
    Xiao, Scott
    Gaier, Eric D.
    Wu, Hank C.
    Angjeli, Endri
    Nuth, Pauline L.
    Bohra, Lisa I.
    Miller, Aaron M.
    Mazow, Malcolm L.
    Stout, Ann U.
    Morse, Christie L.
    Blumenfeld, Louis C.
    Glaser, Stephen R.
    Crouch, Eric
    Ekdawi, Noha S.
    Lyon, Don W.
    Silbert, David I.
    Hunter, David G.
    JOURNAL OF AAPOS, 2021, 25 (02):