Delayed Presentation Injury of Descending Aorta and Bronchus Due to Sewing Needle Penetration: A Case Report

被引:0
|
作者
Chen, Huaidong [1 ]
Wang, Shiqiang [1 ]
Zheng, Dingwen [1 ]
He, Fan [1 ]
机构
[1] Zhejiang Univ, Sch Med, Sir Run Run Shaw Hosp, Dept Cardiac Surg, Hangzhou, Peoples R China
来源
HEART SURGERY FORUM | 2022年 / 25卷 / 02期
关键词
TRACHEAL FOREIGN-BODY; BODIES; REMOVAL;
D O I
10.1532/hsf.4461
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report a case of a tracheal foreign body caused by a sewing needle. After about four months, the patient showed delayed dry cough and hemoptysis. The sewing needle that pierced the tracheal wall damaged the aorta, and we performed endovascular stenting to prevent arterial bleeding and removed it under a bronchoscope. The patient smoothly recovered after the operation. This case proves that treatment strategies for patients with foreign bodies in the trachea can be individualized.
引用
下载
收藏
页码:E253 / E255
页数:3
相关论文
共 50 条
  • [31] Case report and literature review: An intrahepatic sewing needle in a child
    Shi, Hao
    Lv, Zhibao
    Xu, Weijue
    Sheng, Qingfeng
    Huang, Xiong
    Xu, Ting
    FRONTIERS IN PEDIATRICS, 2023, 10
  • [32] THROMBOSIS OF THE DESCENDING THORACIC AORTA - A CASE-REPORT
    JOSEPHSON, GD
    TIEFENBRUN, J
    HARVEY, J
    SURGERY, 1993, 114 (03) : 598 - 600
  • [33] Delayed presentation of a traumatic descending thoracic aorta aneurysm as an aorto-oesophageal fistula
    Mohamed, Saifullah
    Patel, Akshay J.
    Iqbal, Yassir H.
    Ranasinghe, Aaron
    JOURNAL OF SURGICAL CASE REPORTS, 2020, (07):
  • [34] Acute occlusion of the descending thoracic aorta: Report of a case
    Kawahito, K
    Yamaguchi, A
    Adachi, H
    Mizuhara, A
    Murata, S
    Ino, T
    SURGERY TODAY, 1996, 26 (08) : 652 - 654
  • [35] Abdominal Aorta Injury due to Lumbar Disc Hernia Operation: A Case Report
    Hafiz, Erhan
    Geyik, Murat
    Saricicek, Vahap
    Deniz, Hayati
    Hafiz, Meliha
    Asam, Mehmet
    EURASIAN JOURNAL OF EMERGENCY MEDICINE, 2014, 13 (03) : 149 - 150
  • [36] RUPTURE OF AORTA DUE TO RADIATION INJURY - REPORT OF A CASE AND ELECTRON MICROSCOPIC STUDY
    POON, TP
    KANSHEPO.J
    TCHERTKO.V
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1968, 205 (12): : 167 - &
  • [37] CARDIAC TAMPONADE DUE TO GROUP A STREPTOCOCCUS DESCENDING NECROTIZING MEDIASTINITIS: CASE REPORT OF AN UNUSUAL PRESENTATION
    Claveau, David
    Beriault, Marie-Josee
    JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (01): : 12 - 14
  • [38] Delayed presentation of isolated grade III pancreatic injury-a case report
    Ferreira, Maria Joao
    Gallardo, Gabriel
    Vigia, Emanuel
    Filipe, Edite
    Marques, Hugo Pinto
    JOURNAL OF SURGICAL CASE REPORTS, 2023, 2023 (10):
  • [39] Foreign body left bronchus with delayed complications: a case report
    Kuldip Singh Sidhu
    Shivaji Rao
    Amarjit Singh
    Indian Journal of Thoracic and Cardiovascular Surgery, 2012, 28 (4) : 256 - 258
  • [40] A sewing needle migrating into the liver in a child: case report and review of the literature
    Müjdem Nur Azılı
    Ayşe Karaman
    İbrahim Karaman
    Derya Erdoğan
    Yusuf Hakan Çavuşoğlu
    Mustafa Kemal Aslan
    Özden Çakmak
    Pediatric Surgery International, 2007, 23 : 1135 - 1137