Ultra fast electron beam X-ray computed tomography for two-phase flow measurement

被引:87
|
作者
Fischer, F. [1 ]
Hampel, U. [1 ]
机构
[1] Forschungszentrum Dresden Rossendorf eV, Inst Safety Res, D-01314 Dresden, Germany
关键词
D O I
10.1016/j.nucengdes.2009.11.016
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Electron beam X-ray CT is a new technique for a fast measurement of multiphase flows with frame rates of 1000 images per second and more. It gives, in principle, quantitatively accurate images of the flow at high spatial resolution and it is non-intrusive since moderately radiation absorbing vessel walls can be penetrated by X-rays. However, on the road to a technical realisation of such a technique within a computed tomography system many problems have to be solved. As a first prototype for scientific flow measurement studies, we devised and built a fast scanned electron beam X-ray tomography scanner. The scanner consists of an electron beam unit that can be operated at up to 150 kV acceleration voltage and up to 65 mA electron beam current, with the required electron optics for beam adjustment, beam focusing and beam deflection unit and a fast circular CZT detector comprising 240 elements of 1.5 mm x 1.5 mm x 1.5 mm active pixel area. X-ray radiation is produced on a circular water cooled tungsten target. The CT system achieves up to 7000 frames per second with a spatial resolution of 1 mm. First two-phase flow experiments have been carried out on gas-water flows in bubble columns. Further, a vertical test section made of titanium alloy has been installed at the TOPFLOW facility and will be used in future to study the evolution of two-phase gas-water pipe flow at high pressures and temperatures. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:2254 / 2259
页数:6
相关论文
共 50 条
  • [21] Ultrafast X-Ray Computed Tomography Imaging for Hydrodynamic Investigations of Gas-Liquid Two-Phase Flow in Centrifugal Pumps
    Schaefer, Thomas
    Neumann-Kipping, Martin
    Bieberle, Andre
    Bieberle, Martina
    Hampel, Uwe
    JOURNAL OF FLUIDS ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (04):
  • [22] Quantitative cone beam X-ray luminescence tomography/X-ray computed tomography imaging
    Chen, Dongmei
    Zhu, Shouping
    Chen, Xueli
    Chao, Tiantian
    Cao, Xu
    Zhao, Fengjun
    Huang, Liyu
    Liang, Jimin
    APPLIED PHYSICS LETTERS, 2014, 105 (19)
  • [23] Multiphase flow investigations with ultrafast electron beam X-ray tomography
    Hampel, Uwe
    Barthel, Frank
    Bieberle, Martina
    Schubert, Markus
    Schleicher, Eckhard
    7TH INTERNATIONAL SYMPOSIUM ON MEASUREMENT TECHNIQUES FOR MULTIPHASE FLOWS, 2012, 1428
  • [24] X-ray luminescence computed tomography using a focused x-ray beam
    Zhang, Wei
    Lun, Michael C.
    Nguyen, Alex Anh-Tu
    Li, Changqing
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (11)
  • [25] Ultra-fast x-ray tomography for multi-phase flow interface dynamic studies
    Misawa, M.
    Tiseanu, I
    Prasser, H-M
    Ichikawa, N.
    Akai, M.
    KERNTECHNIK, 2003, 68 (03) : 85 - 90
  • [26] Development and validation of an X-ray tomograph for two-phase flow
    Hervieu, E
    Jouet, E
    Desbat, L
    VISUALIZATION AND IMAGING IN TRANSPORT PHENOMENA, 2002, 972 : 87 - 94
  • [27] Fast X-Ray Luminescence Computed Tomography Imaging
    Liu, Xin
    Liao, Qimei
    Wang, Hongkai
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2014, 61 (06) : 1621 - 1627
  • [28] Experimental facility for two-and three-dimensional ultrafast electron beam x-ray computed tomography
    Stuerzel, T.
    Bieberle, M.
    Laurien, E.
    Hampel, U.
    Barthel, F.
    Menz, H. -J.
    Mayer, H. -G.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02):
  • [29] Porosity Measurement Method by X-ray Computed Tomography
    Prokop, Josef
    Sveda, Libor
    Jancarek, Alexandr
    Pina, Ladislav
    FRACTOGRAPHY OF ADVANCED CERAMICS III, 2009, 409 : 402 - 405
  • [30] Measurement of voids in composites by X-ray Computed Tomography
    Nikishkov, Yuri
    Airoldi, Luca
    Makeev, Andrew
    COMPOSITES SCIENCE AND TECHNOLOGY, 2013, 89 : 89 - 97