Holdup, pressure drop, and flooding in packed countercurrent columns for the gas extraction

被引:43
|
作者
Stockfleth, R [1 ]
Brunner, G [1 ]
机构
[1] TU Hamburg Harburg, Arbeitsbereich Therm Verfahrenstech, D-21071 Hamburg, Germany
关键词
D O I
10.1021/ie000466q
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The hydrodynamic behavior, i.e., flooding, liquid holdup, and pressure drop of countercurrent columns with two random packings, Raschig rings and Berl saddles, and two gauze packings, Sulzer CY and Sulzer EX, is scrutinized at temperatures between 313 and 373 K and pressures between 8 and 30 MPa using carbon dioxide as the supercritical solvent and water and olive oil deodorizer distillate as liquid phases. Two models are employed to correlate the experimental data: a sophisticated mechanistic approach;based on the liquid holdup and a well-known empirical approach for the flooding point. The experimental data for the dry pressure drop and the liquid holdup below the loading point are successfully correlated using modified models from normal pressure operation. The flooding points can be correlated with good accuracy as well.
引用
下载
收藏
页码:347 / 356
页数:10
相关论文
共 50 条
  • [31] Hydrodynamics of a packed countercurrent column for the gas extraction
    TU Hamburg-Harburg, Arbeitsbereich Thermische V., Eissendorfer Strasse 38, 21071 Hamburg, Germany
    Ind. Eng. Chem. Res., 10 (4000-4006):
  • [32] A UNIFIED MODEL FOR COUNTERCURRENT VAPOR LIQUID PACKED-COLUMNS .1. PRESSURE-DROP
    HANLEY, B
    DUNBOBBIN, B
    BENNETT, D
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 1994, 33 (05) : 1208 - 1221
  • [33] Liquid dispersion, gas holdup and frictional pressure drop in a packed bubble column at elevated pressures
    Therning, P
    Rasmuson, A
    CHEMICAL ENGINEERING JOURNAL, 2001, 81 (1-3) : 331 - 335
  • [34] GAS HOLDUP AND MIXING CHARACTERISTICS OF PACKED BUBBLE-COLUMNS
    NIRANJAN, K
    PANGARKAR, VG
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1984, 29 (02): : 101 - 111
  • [35] LOW-PRESSURE DROP GAS DISTRIBUTORS FOR PACKED DISTILLATION-COLUMNS
    MUIR, LA
    BRIENS, CL
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1986, 64 (06): : 1027 - 1037
  • [36] PRESSURE DROP THROUGH PACKED DISTILLATION COLUMNS
    HANDS, CHG
    WHITT, FR
    GREGORY, KS
    CHEMISTRY & INDUSTRY, 1950, (24) : 451 - 451
  • [37] AXIAL-DISPERSION, HOLDUP AND FLOODING CHARACTERISTICS IN PULSED EXTRACTION COLUMNS
    YU, YH
    KIM, SD
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1987, 65 (05): : 752 - 758
  • [38] Liquid holdup and flooding in packed towers
    Elgin, JC
    Weiss, FB
    INDUSTRIAL AND ENGINEERING CHEMISTRY, 1939, 31 : 435 - 445
  • [39] Performance comparison of different pressure drop, hold-up and flooding point correlations for packed columns
    Wolf-Zoellner, V.
    Seibert, F.
    Lehner, M.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2019, 141 : 388 - 401
  • [40] Spray extraction columns: Drop size and dispersed-phase holdup
    Varfolomeev B.G.
    Pebalk V.L.
    Chigogidze K.Sh.
    Lan N.N.
    Fernando R.S.
    Theoretical Foundations of Chemical Engineering, 2000, 34 (6) : 556 - 561