Radiation Dose Monitoring for Fluoroscopically Guided Interventional Procedures: Effect on Patient Radiation Exposure

被引:21
|
作者
Liu, Bob [1 ]
Hirsch, Joshua A. [1 ]
Li, Xinhua [1 ]
Sheridan, Robert M. [1 ]
Rehani, Madan M. [1 ]
Zheng, Hui [3 ]
Rabinov, James D. [1 ,2 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, 55 Fruit St, Boston, MA 02114 USA
[2] Massachusetts Gen Hosp, Dept Neurosurg, 55 Fruit St, Boston, MA 02114 USA
[3] Massachusetts Gen Hosp, Biostat Ctr, 55 Fruit St, Boston, MA 02114 USA
关键词
SKIN INJURIES; GUIDELINES;
D O I
10.1148/radiol.2019180799
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To analyze the clinical effect of continuous dose monitoring and patient follow-up for fluoroscopically guided vascular interventional procedures over 8 years. Materials and Methods: In this retrospective study, an in-house semiautomated system was developed for fluoroscopic dose monitoring. The quarterly number of procedures from January 2010 to December 2017 was analyzed with count time series to estimate quarterly change rate. Technologists recorded four dose surrogates in custom fields of institutional dictation software through a Web interface. Radiation doses were transferred automatically to the radiology report and a centralized dose database when the radiologist initiated procedure dictation. A medical physicist reported weekly on procedures with air kerma at the reference point (K-a,K-r) of 2 Gy or higher to a division-designated radiologist and hospital radiation safety committee who required the attending radiologist to set up follow-up appointments for patients who underwent procedures with a K-a,K-r greater than or equal to 5 Gy. Results: There were a total of 41 585 procedures; 1553 (3.7%) procedures had a K-a,K-r of 2-5 Gy. Among 240 procedures with K-a,K-r greater than 5 Gy, 22 had K-a,K-r greater than 9 Gy. The percentage of high K-a,K-r procedures decreased over time, going from 5.9% in 2010 to 2.0% in 2017 for procedures with K-a,K-r of 2-5 Gy and from 1.0% in 2010 to 0.13% in 2017 for procedures with K-a,K-r greater than or equal to 5 Gy. Relative reduction per quarter was approximately 2.7% (95% confidence interval: 1.5%, 3.8%) for K-a,K-r of 2-5 Gy and 4.5% (95% confidence interval: 1.5%, 7.6%) for K-a,K-r greater than or equal to 5 Gy. Conclusion: Eight-year temporal trends show three-to eightfold reduction in the number of high-dose procedures. (C) RSNA, 2019
引用
收藏
页码:744 / 749
页数:6
相关论文
共 50 条
  • [41] Strategies for radiation exposure-sparing in fluoroscopically guided invasive cardiovascular procedures
    Fiorilli, Paul N.
    Kobayashi, Taisei
    Giri, Jay
    Hirshfeld, John W., Jr.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2020, 95 (01) : 118 - 127
  • [42] Anticipation of radiation dose to the conceptus from occupational exposure of pregnant staff during fluoroscopically guided electrophysiological procedures
    Damilakis, J
    Perisinakis, K
    Theocharopoulos, N
    Tzedakis, A
    Manios, E
    Vardas, P
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (07) : 773 - 780
  • [43] MONITORING AND REDUCTION OF PATIENT AND STAFF RADIATION EXPOSURE DURING INTERVENTIONAL AND THERAPEUTIC NEURORADIOLOGY PROCEDURES
    KUAN, HM
    MANZIONE, JV
    FERRETTI, JA
    [J]. RADIOLOGY, 1995, 197 : 359 - 359
  • [44] Patient Brain-Dose Estimation for Fluoroscopically-Guided Neuro-Interventional Procedures
    Xiong, Z.
    Guo, C.
    Troville, J.
    Rudin, S.
    Bednarek, D. R.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E694 - E694
  • [45] FLUOROSCOPICALLY GUIDED INTERVENTIONAL PROCEDURES OF THE ESOPHAGUS
    DELANGE, EE
    SHAFFER, HA
    [J]. RADIOLOGY, 1995, 197 : 508 - 509
  • [46] Radiation injury to skin following fluoroscopically guided procedures
    Malkinson, FD
    [J]. ARCHIVES OF DERMATOLOGY, 1996, 132 (06) : 695 - 696
  • [47] EVALUATING THE MAXIMUM PATIENT RADIATION DOSE IN CARDIAC INTERVENTIONAL PROCEDURES
    Kato, Mamoru
    Chida, Koichi
    Sato, Tadaya
    Oosaka, Hajime
    Tosa, Tetsuo
    Kadowaki, Ken
    [J]. RADIATION PROTECTION DOSIMETRY, 2011, 143 (01) : 69 - 73
  • [48] High-Dose Fluoroscopically Guided Procedures in Patients: Radiation Management Recommendations for Interventionalists
    Madan M. Rehani
    Donald L. Miller
    Vinit Baliyan
    [J]. CardioVascular and Interventional Radiology, 2021, 44 : 849 - 856
  • [49] High-Dose Fluoroscopically Guided Procedures in Patients: Radiation Management Recommendations for Interventionalists
    Rehani, Madan M.
    Miller, Donald L.
    Baliyan, Vinit
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2021, 44 (06) : 849 - 856
  • [50] Patient radiation exposure related to complexity of coronary interventional procedures
    Federman, J
    Cusma, JT
    Holmes, DR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 54A - 54A