Limitations of Nasal Nitric Oxide Measurement for Diagnosis of Primary Ciliary Dyskinesia with Normal Ultrastructure

被引:22
|
作者
Raidt, Johanna [1 ]
Krenz, Henrike [2 ]
Tebbe, Johannes [1 ]
Grosse-Onnebrink, Joerg [1 ]
Olbrich, Heike [1 ]
Loges, Niki Tomas [1 ]
Biebach, Luisa [1 ]
Schmalstieg, Christian [1 ]
Kessler, Christina [1 ]
Wallmeier, Julia [1 ]
Dworniczak, Bernd [1 ]
Pennekamp, Petra [1 ]
Dugas, Martin [3 ]
Werner, Claudius [4 ]
Omran, Heymut [1 ]
机构
[1] Univ Hosp Muenster, Dept Gen Pediat, Pediat Pulmonol, Munster, Germany
[2] Univ Munster, Inst Med Informat, Munster, Germany
[3] Heidelberg Univ Hosp, Inst Med Informat, Heidelberg, Germany
[4] Helios Kliniken Schwerin, Dept Gen Pediat, Pediat Pulmonol, Schwerin, Germany
关键词
cilia; genetic; ciliary beat frequency; TRANSMISSION ELECTRON-MICROSCOPY; MUTATIONS; PREVALENCE; VARIANTS; ACCURACY;
D O I
10.1513/AnnalsATS.202106-728OC
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Rationale: Primary ciliary dyskinesia (PCD) is a heterogeneous, multisystem disorder characterized by defective ciliary beating. Diagnostic guidelines of the American Thoracic Society and European Respiratory Society recommend measurement of nasal nitric oxide (nNO) for PCD diagnosis. Several studies demonstrated low nNO production rates in PCD individuals, but underlying causes remain elusive. Objectives: To determine nNO production rates in a well-characterized PCD cohort, including subgroup analyses with regard to ultrastructural and ciliary beating phenotypes. Methods: This study included 301 individuals assessed according to European Respiratory Society guidelines. Diagnostic cutoffs for nNO production rates for this study cohort and subgroups with normal and abnormal ultrastructure were determined. Diagnostic accuracy was also tested for the widely used 77 nl/min cutoff in this study cohort. The relationship between nNO production rates and ciliary beat frequencies (CBFs) was evaluated. Results: The study cohort comprised 180 individuals with definite PCD diagnosis, including 160 individuals with genetic diagnosis, 16 individuals with probable PCD diagnosis, and 105 disease controls. The 77 nl/min nNO cutoff showed a test sensitivity of 0.92 and specificity of 0.86. Test sensitivity was lower (0.85) in the subgroup of 47 PCD individuals with normal ultrastructure compared with 133 PCD individuals with abnormal ultrastructure (0.95). The optimal diagnostic cutoff for the nNO production rate for the whole study cohort was 69.8 nl/min (sensitivity, 0.92; specificity, 0.89); however, it was 107.8 nl/min (sensitivity, 0.89; specificity, 0.78) for the subgroup of PCD with normal ultrastructure. PCD individuals with normal ultrastructure compared with abnormal ultrastructure showed higher ciliary motility. Consistently, PCD individuals with higher CBFs showed higher nNO production rates. In addition, laterality defects occurred less frequently in PCD with normal ultrastructure. Conclusions: Measurements of nNO below the widely used 77 nl/min cutoff are less sensitive in detecting PCD individuals with normal ultrastructure. Our findings indicate that higher nNO production in this subgroup with a higher cutoff for the nNO production rate (107.8 nl/min) and higher residual ciliary motility is dependent on the underlying molecular PCD defect. Higher nNO production rates, higher residual CBFs, and the lower prevalence of laterality defects hamper diagnosis of PCD with normal ultrastructure. Adjusting the cutoff of nNO production rate to 107.8 nl/min might promote diagnosing PCD with normal ultrastructure.
引用
收藏
页码:1275 / 1284
页数:10
相关论文
共 50 条
  • [21] Nasal nitric oxide measurement in children for the diagnosis of primary ciliary dyskinesia: European Respiratory Society technical standard
    Beydon, Nicole
    Kouis, Panayiotis
    Marthin, June K.
    Latzin, Philipp
    Colas, Murielle
    Davis, Stephanie D.
    Haarman, Eric
    Harris, Amanda Lea
    Hogg, Claire
    Kilbride, Emma
    Kuehni, Claudia E.
    Marangu, Diana
    Nielsen, Kim G.
    Pendergrast, Catherine
    Robinson, Phil
    Rumman, Nisreen
    Rutter, Matthew
    Walker, Woolf T.
    Ferkol, Thomas
    Lucas, Jane S.
    EUROPEAN RESPIRATORY JOURNAL, 2023, 61 (04)
  • [22] Nasal Nitric Oxide Measurement in Primary Ciliary Dyskinesia A Technical Paper on Standardized Testing Protocols
    Shapiro, Adam J.
    Dell, Sharon D.
    Gaston, Benjamin
    O'Connor, Michael
    Marozkina, Nadzeya
    Manion, Michele
    Hazucha, Milan J.
    Leigh, Margaret W.
    ANNALS OF THE AMERICAN THORACIC SOCIETY, 2020, 17 (02) : E1 - E12
  • [23] The utility of nasal nitric oxide in the diagnostic evaluation of primary ciliary dyskinesia
    Carr, Katherine A.
    Moore, Paul E.
    O'Connor, Michael G.
    PEDIATRIC PULMONOLOGY, 2024, 59 (05) : 1410 - 1417
  • [24] Agenesis of paranasal sinuses and nasal nitric oxide in primary ciliary dyskinesia
    Pifferi, M.
    Bush, A.
    Caramella, D.
    Di Cicco, M.
    Zangani, M.
    Chinellato, I.
    Macchia, P.
    Boner, A. L.
    EUROPEAN RESPIRATORY JOURNAL, 2011, 37 (03) : 566 - 571
  • [25] Tidal Nasal Nitric Oxide as a Screening Test for Primary Ciliary Dyskinesia
    Donovan, S. L.
    Shoemark, A.
    Hogg, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [26] The Utility of Nasal Nitric Oxide in the Diagnostic Evaluation of Primary Ciliary Dyskinesia
    Carr, K. A.
    O'Connor, M. G.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2023, 207
  • [27] Nasal nitric oxide measurements to screen children for primary ciliary dyskinesia
    Corbelli, R
    Bringolf-Isler, B
    Amacher, A
    Sasse, B
    Spycher, M
    Hammer, J
    CHEST, 2004, 126 (04) : 1054 - 1059
  • [28] Toward Standardization Of Nasal Nitric Oxide Testing For Primary Ciliary Dyskinesia
    Baker, B. R.
    Chawla, K. K.
    Hazucha, M.
    Knowles, M. R.
    Leigh, M.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [29] Nitric oxide in primary ciliary dyskinesia
    Walker, Woolf T.
    Jackson, Claire L.
    Leckie, Peter M.
    Hogg, Claire
    Lucas, Jane S.
    EUROPEAN RESPIRATORY JOURNAL, 2012, 40 (04) : 1024 - 1032
  • [30] Diagnostic accuracy of nasal nitric oxide measurement for establishing diagnosis of primary ciliary dyskinesia: A systematic review and meta-analysis
    Kouis, Panayiotis
    Papatheodorou, Stefania
    Yiallouros, Panayiotis
    EUROPEAN RESPIRATORY JOURNAL, 2015, 46