Effects of desensitizing agents on human dentin permeability

被引:0
|
作者
Camps, J
Pizant, S
Dejou, J
Franquin, JC
机构
[1] Sun Med Co, Shiga, Japan
[2] John O Butler, Chicago, IL USA
[3] Hereaus Kulzer, Dormagen, Germany
[4] Buehler Ltd, Lake Bluff, IL USA
[5] Serovial, Neuf Brisah, France
[6] Gibco, Cergy Pontoise, France
[7] De Marco Engn SA, Geneva, Switzerland
[8] Electron Microscope Sci, Ft Washington, PA USA
[9] Joel Corp, Kyoto, Japan
来源
AMERICAN JOURNAL OF DENTISTRY | 1998年 / 11卷 / 06期
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the in vitro effects of three desensitizing agents on hydraulic conductance of human dentin: Protect (n=10), Gluma Desensitizer (n=10), MS Coat (n=10) (Pain-Free in the USA). Materials and Methods: Dentin discs were prepared from 40 freshly extracted normal human third molars. The pulpal side of the dentin discs was etched with 37% phosphoric acid for 15 s and then rinsed under tap water. The coronal side was sequentially ground and the dentin discs were sonicated for 30 min. The hydraulic conductance was measured filtering 20% serum in phosphate buffered saline under a pressure of 15 cm H2O. The hydraulic conductance of each dentin specimen was measured before using the desensitizing agent and this value was designated as 100%. Thirty dentin discs were treated, the hydraulic conductance was remeasured and expressed as a percentage of the hydraulic conductance of that specimen before treatment. The teeth were stored for 1 month at 37 degrees C in deionized water and the hydraulic conductance of the 40 dentin discs was recorded again. Ten dentin discs were left untreated to serve as a control. Results: No statistical difference was found between the immediate hydraulic conductance of the three groups after treatment. After 1-month storage, the control group showed a statistically higher hydraulic conductance than the three treated groups. There was no statistical difference between the three dentin desensitizing agents evaluated.
引用
收藏
页码:286 / 290
页数:5
相关论文
共 50 条
  • [21] Improving the effect of desensitizing agents on the hydraulic conductance of human dentin in vitro.
    Pereira, JC
    Segala, AD
    Paganini, EF
    Carvalho, RM
    JOURNAL OF DENTAL RESEARCH, 1997, 76 : 660 - 660
  • [22] Effects of the desensitizing agents Gluma and Hyposen on the tensile bond strength of dentin adhesives
    Kobler, Annett
    Schaller, Hans Guenter
    Gernhardt, Christian R.
    AMERICAN JOURNAL OF DENTISTRY, 2008, 21 (06): : 388 - 392
  • [23] Micromorphological Evaluation of Dentin Treated with Different Desensitizing Agents
    Osmari, Deise
    de Oliveira Ferreira, Ana Carolina
    Bello, Mariana de Carlo
    Susin, Alexandre Henrique
    Correa Aranha, Ana Cecilia
    Marquezan, Marcela
    da Silveira, Bruno Lopes
    JOURNAL OF LASERS IN MEDICAL SCIENCES, 2013, 4 (03) : 140 - 146
  • [24] Effects of desensitizing toothpastes on the permeability of dentin after different brushing times: An in vitro study
    Yang, Meng
    Lin, Hong
    Jiang, Ruodan
    Zheng, Gang
    AMERICAN JOURNAL OF DENTISTRY, 2016, 29 (06): : 345 - 351
  • [25] SEM INVESTIGATION OF DESENSITIZING AGENTS IN THE DENTIN DISC MODEL
    LING, TYY
    GILLAM, DG
    BARBER, PM
    MORDAN, NJ
    CRITCHELL, J
    JOURNAL OF DENTAL RESEARCH, 1995, 74 : 430 - 430
  • [26] The Effects of Different Desensitizing Agents on the Shear Bond Strength of Adhesive Resin Cement to Dentin
    Kulunk, Safak
    Sarac, Duygu
    Kulunk, Tolga
    Karakas, Ozlem
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2011, 23 (06) : 380 - 387
  • [27] The dentin tubule occlusion effects of desensitizing agents and the stability against acids and brushing challenges
    Wang, Zhejun
    Ma, Xiao
    Jiang, Tao
    Wang, Yining
    Feng, Yunzhi
    Li, Rong
    AMERICAN JOURNAL OF DENTISTRY, 2015, 28 (03): : 128 - 132
  • [28] Effect of desensitizing agents on the resin bond strength to sound dentin
    Alawad, Fahad Ibrahim
    Araujo, Isaac Jordao de Souza
    de Carvalho, Ana Beatriz Gomes
    Neiva, Gisele de Faria
    Dennison, Joseph Debrune
    Yaman, Peter
    Bottino, Marco C.
    ODONTOLOGY, 2024, 112 (02) : 435 - 443
  • [29] A clinical comparison of the efficacy of two dentin desensitizing agents.
    Morris, M
    Davis, R
    Richardson, B
    JOURNAL OF DENTAL RESEARCH, 1998, 77 : 275 - 275
  • [30] Clinical evaluation of three desensitizing agents in relieving dentin hypersensitivity
    Pamir, T.
    Dalgar, H.
    Onal, B.
    OPERATIVE DENTISTRY, 2007, 32 (06) : 544 - 548