Pharmacokinetic Properties and Tolerability of Low-dose SoluMatrix Diclofenac

被引:16
|
作者
Desjardins, Paul J. [1 ]
Olugemo, Kemi [2 ]
Solorio, Daniel [3 ]
Young, Clarence L. [3 ]
机构
[1] Desjardins Associates LLC, Maplewood, NJ USA
[2] Parexel Int Corp, Baltimore, MD USA
[3] Iroko Pharmaceut LLC, Philadelphia, PA USA
关键词
diclofenac; pain; pharmacokinetics; SoluMatrix; submicron; NONSTEROIDAL ANTIINFLAMMATORY DRUGS; ORAL DICLOFENAC; POTASSIUM; EFFICACY; SINGLE; CAPSULES; SAFETY; PAIN; BIOAVAILABILITY; ABSORPTION;
D O I
10.1016/j.clinthera.2014.10.018
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Purpose: This study compared the pharmacokinetic properties and safety profile of low-dose (18- and 35-mg) diclofenac capsules manufactured using SoluMatrix Fine Particle Technology (Trademark of iCeutica Inc. (Philadelphia, Pennsylvania), and the technology is licensed to Iroko Pharmaceuticals, LLC (Philadelphia, Pennsylvania) for exclusive use in NSAIDs), which produces submicron-sized drug particles with enhanced dissolution properties, to those of diclofenac potassium immediate-release (IR) 50-mg tablets. Methods: This Phase 1, single-center, randomized, open-label, single-dose crossover study was conducted in 40 healthy volunteers. Subjects received, in randomized order, SoluMatrix diclofenac 18- or 35-mg capsules in the fasting condition, SoluMatrix diclofenac 35-mg capsules under fed conditions, and diclofenac potassium IR 50-mg tablets under fasting and fed conditions. Pharmacokinetic parameters (T-max, C-max, AUC(0-t), AUC(0-infinity)) were calculated from the concentrations of diclofenac in the plasma. Absorption, food effect, and dose proportionality were determined using a mixed-model ANOVA for C-max, AUC(0-t), and AUC(0-infinity). Tolerability was assessed by recording adverse events, physical examination findings, vital sign measurements: clinical laboratory test results. Findings: Overall, 35 healthy volunteers aged 18 to 52 years completed the study. The mean age of the subjects was 33.4 years, and approximately half were men (47.5%). Median T-max values were similar between the low-dose SoluMatrix diclofenac 35-mg capsules and the diclofenac potassium IR 50-mg tablets (both, similar to 1.0 hour). The mean maximum plasma concentration (C-max) after the administration of low-dose SoluMatrix diclofenac 35-mg capsules was 26% lower than that with diclofenac potassium IR 50-mg tablets under fasting conditions (868.72 vs 1194.21 ng/mL). The administration of low-dose SoluMatrix diclofenac 35-mg capsules was associated with a 23% lower overall systemic exposure compared with that of diclofenac potassium IR 50-mg tablets under fasting conditions. Food decreased the rate but not the overall extent of absorption of SoluMatrix diclofenac. No serious AFs and no clinically significant abnormalities in physical examination findings, including vital sign measurements, or clinical laboratory test results, were noted during this study. Implications: The pharmacokinetic properties of low-dose SoluMatrix diclofenac capsules in the healthy volunteers in this study suggest rapid diclofenac absorption as measured by T-max. Low-dose SoluMatrix diclofenac capsules represent a potential option for the management of acute and osteoarthritis-related pain. (C) 2015 Elsevier HS Journals, Inc. All rights reserved.
引用
收藏
页码:448 / 461
页数:14
相关论文
共 50 条
  • [41] Efficacy and tolerability of low-dose transdermal estrogen (Oesclim®) in the treatment of menopausal symptoms
    Gadomska, H
    Barcz, E
    Cyganek, A
    Leocmach, Y
    Chadha-Boreham, H
    Marianowski, L
    CURRENT MEDICAL RESEARCH AND OPINION, 2002, 18 (02) : 97 - 102
  • [42] Efficacy and tolerability of initial low-dose lenvatinib to treat differentiated thyroid cancer
    Yamazaki, Haruhiko
    Iwasaki, Hiroyuki
    Takasaki, Hirotaka
    Suganuma, Nobuyasu
    Sakai, Rika
    Masudo, Katsuhiko
    Nakayama, Hirotaka
    Rino, Yasushi
    Masuda, Munetaka
    MEDICINE, 2019, 98 (10)
  • [43] DISCRIMINATIVE STIMULUS PROPERTIES OF LOW-DOSE COCAINE
    EMMETTOGLESBY, MW
    WURST, MF
    LAL, H
    PSYCHOPHARMACOLOGY, 1982, 76 (04) : A7 - A7
  • [44] Comparative efficacy and tolerability of low-dose pravastatin versus lovastatin in patients with hypercholesterolemia
    Strauss, WE
    Lapsley, D
    Gaziano, JM
    AMERICAN HEART JOURNAL, 1999, 137 (03) : 458 - 462
  • [45] Safety and tolerability of a new low-dose contraceptive patch in obese and nonobese women
    Kaunitz, Andrew M.
    Archer, David F.
    Mishell, Daniel R., Jr.
    Foegh, Marie
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2015, 212 (03) : 318.e1 - 318.e8
  • [46] The safety and tolerability of low-dose irradiation for the management of gynaecomastia caused by antiandrogen monotherapy
    Dicker, AP
    LANCET ONCOLOGY, 2003, 4 (01): : 30 - 36
  • [47] Efficacy and Tolerability of Low-Dose Nintedanib for Idiopathic Pulmonary Fibrosis in the Real World
    Kato, M.
    Arai, Y.
    Tateyama, M.
    Nakazawa, S.
    Motomura, H.
    Ochi, Y.
    Sumiyoshi, I.
    Watanabe, J.
    Ihara, H.
    Togo, S.
    Sasaki, S.
    Takahashi, K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [49] Continuous low-dose diclofenac infusion for fever control in patients with acute neurological lesions
    Caricato, A
    Conti, G
    Mercurio, G
    Mancino, A
    Santilli, F
    Antonelli, M
    Proietti, R
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2004, 51 (09): : 950 - 951
  • [50] Analgesic efficacy of low-dose diclofenac versus paracetamol and placebo in postoperative dental pain
    Kubitzek, F
    Ziegler, G
    Gold, MS
    Liu, JMH
    Ionescu, E
    JOURNAL OF OROFACIAL PAIN, 2003, 17 (03): : 237 - 244