Bending performance of post-fire lightweight polyethylene metal sandwich panels

被引:1
|
作者
Chen, Zhihao [1 ]
Wu, Tianran [1 ]
Zhang, Yipeng [1 ]
Huang, Chenxi [1 ]
Zhou, Ru [1 ]
Jiang, Juncheng [2 ]
机构
[1] Nanjing Tech Univ, Coll Safety Sci & Engn, Jiangsu Key Lab Urban & Ind Safety, Nanjing 211816, Peoples R China
[2] Changzhou Univ, Sch Environm & Safety Engn, Changzhou 213164, Peoples R China
基金
中国国家自然科学基金;
关键词
Post-fire sandwich panels; Span; Bending test; Mechanical properties; FLEXURAL BEHAVIOR; COMPOSITE; TEMPERATURE;
D O I
10.1007/s43452-022-00456-y
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigated the bending performance of post-fire lightweight polyethylene metal sandwich panels with different aspect ratios and span conditions using actual fires and post-fire three-point bending tests. The damage patterns and buckling behavior of sandwich panels after an actual fire are discussed. The effects of lamination with dimensional ratios (vertically and horizontally laminated) and span (single and double-span) on parameters, such as fire spread behavior, buckling behavior, load-deflection, bending modulus degradation efficiency, and residual bending stiffness were investigated. The results showed that the double-span fixation mode formed a double-peaked flame, becoming more evident as the aspect ratio decreased. The double-span helped suppress the upward propagation of the flame and reduced the degradation of the bending modulus. The bending stiffness was 10-20% higher than that of the single-span sandwich panels. In addition, the maximum service limit deflection of post-fire sandwich panels with different spans was also derived based on the normal limit of use standard.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Post-fire seismic performance of reinforced concrete structures
    Duzgun, Oguz Akin
    Kucuk, Elif Nazli
    STRUCTURES, 2024, 59
  • [22] Assessment of reinforced concrete slabs post-fire performance
    Shachar, Yedidya M.
    Dancygier, Avraham N.
    FIRE SAFETY JOURNAL, 2020, 111
  • [23] Post-fire succession indices performance in a Mediterranean ecosystem
    Matossian, Albert Dicran
    Matsinos, Yiannis G.
    Konstantinidis, Pavlos
    Moustakas, Aristides
    STOCHASTIC ENVIRONMENTAL RESEARCH AND RISK ASSESSMENT, 2013, 27 (02) : 323 - 335
  • [24] Fire response of high-performance concrete frames and their post-fire seismic performance
    Xiao, Jian-Zhuang
    Li, Jie
    Huang, Zhan-Fei
    ACI STRUCTURAL JOURNAL, 2008, 105 (05) : 531 - 540
  • [25] Post-fire low velocity impact response of marine grade sandwich composites
    Ulven, C. A.
    Vaidya, U. K.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2006, 37 (07) : 997 - 1004
  • [26] Fire response of high-performance concrete frames and their post-fire seismic performance
    Building Engineering Department, Tongji University, Shanghai, China
    不详
    ACI Struct J, 2008, 5 (531-540):
  • [27] Bending Performance and Failure Behavior of Wooden Sandwich Panels with Corrugated Cores
    Smardzewski, Jerzy
    Krzyzaniak, Lukasz
    Wojciechowski, Krzysztof W.
    Pelinski, Krzysztof
    Tretiakov, Konstantin, V
    Narojczyk, Jakub W.
    PHYSICA STATUS SOLIDI B-BASIC SOLID STATE PHYSICS, 2022, 259 (12):
  • [28] Fie performance of sandwich composites with intumescent mat protection: Evolving thermal insulation, post-fire performance and rail industry testing
    Zhu, Chenkai
    Li, Saihua
    Li, Jingjing
    Clement, Mandy
    Rudd, Chris
    Yi, Xiaosu
    Liu, Xiaoling
    FIRE SAFETY JOURNAL, 2020, 116
  • [29] Structural performance of wood based sandwich panels in four point bending
    Edgars, Labans
    Kaspars, Zudrags
    Kaspars, Kalnins
    MODERN BUILDING MATERIALS, STRUCTURES AND TECHNIQUES, 2017, 172 : 628 - 633
  • [30] The Unquantified Risk of Post-Fire Metal Concentration in Soil: a Review
    Abraham, Joji
    Dowling, Kim
    Florentine, Singarayer
    WATER AIR AND SOIL POLLUTION, 2017, 228 (05):