CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

被引:70
|
作者
Prosch, Helmut [1 ]
Stadler, Alfred [2 ]
Schilling, Matthias [1 ]
Buerklin, Sandra [1 ]
Eisenhuber, Edith [1 ]
Schober, Ewald [1 ]
Mostbeck, Gerhard [1 ]
机构
[1] Otto Wagner Hosp, Dept Radiol, A-1140 Vienna, Austria
[2] Hietzing Hosp, Dept Radiol, A-1130 Vienna, Austria
关键词
CT guided biopsy; CT fluoroscopy; Pulmonary nodules; INTERVENTIONAL PROCEDURES; COMPUTED-TOMOGRAPHY; EXPOSURE; PATIENT; NODULES;
D O I
10.1016/j.ejrad.2011.01.064
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement. (C) 2011 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1029 / 1033
页数:5
相关论文
共 50 条
  • [21] Effect of Body Habitus on Radiation Dose During CT Fluoroscopy-Guided Spine Injections
    Viola, Ronald J.
    Nguyen, Giao B.
    Yoshizumi, Terry T.
    Stinnett, Sandra S.
    Hoang, Jenny K.
    Kranz, Peter G.
    INTERVENTIONAL NEURORADIOLOGY, 2014, 20 (05) : 525 - 532
  • [22] Radiation dose to the radiologist's hand during continuous CT fluoroscopy-guided interventions
    Stoeckelhuber, BM
    Leibecke, T
    Schulz, E
    Melchert, UH
    Bergmann-Koester, CU
    Helmberger, T
    Gellissen, J
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2005, 28 (05) : 589 - 594
  • [23] CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses
    Iguchi, T.
    Hiraki, T.
    Matsui, Y.
    Fujiwara, H.
    Sakurai, J.
    Masaoka, Y.
    Uka, M.
    Tanaka, T.
    Gobara, H.
    Kanazawa, S.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2018, 99 (02) : 91 - 97
  • [24] CT Fluoroscopy-Guided Cervical Interlaminar Steroid Injections: Safety, Technique, and Radiation Dose Parameters
    Kranz, P. G.
    Raduazo, P.
    Gray, L.
    Kilani, R. K.
    Hoang, J. K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (07) : 1221 - 1224
  • [25] CT fluoroscopy-guided abdominal interventions: Techniques, results, and radiation exposure
    Silverman, SG
    Tuncali, K
    Adams, DF
    Nawfel, RD
    Zou, KH
    Judy, PF
    RADIOLOGY, 1999, 212 (03) : 673 - 681
  • [26] Transosseous Route for CT Fluoroscopy-Guided Radiofrequency Ablation of Lung Tumors
    Iguchi, Toshihiro
    Hiraki, Takao
    Ishii, Hiroaki
    Gobara, Hideo
    Fujiwara, Hiroyasu
    Matsui, Yusuke
    Kanazawa, Susumu
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2015, 26 (11) : 1694 - 1698
  • [27] Effect of the learning process on procedure times and radiation exposure for CT fluoroscopy-guided percutaneous biopsy procedures
    Gianfelice, D
    Lepanto, L
    Perreault, P
    Chartrand-Lefebvre, C
    Milette, PC
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2000, 11 (09) : 1217 - 1221
  • [28] Analysis of factors influencing accuracy and complications in CT-guided lung biopsy
    Nakatani, Miyuki
    Tanigawa, Noboru
    Kariya, Shuji
    Komemushi, Atsushi
    Yagi, Rie
    Sawada, Satoshi
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2012, 21 (06) : 415 - 422
  • [29] Low-dose CT fluoroscopy-guided interventional minimally invasive robot
    He, Xiaofeng
    Xiao, Yueyong
    Zhang, Xiao
    Zhang, Xiaobo
    Zhang, Xin
    Wei, Yingtian
    Zhang, Zhongliang
    Xue, Xiaodong
    Zhang, Shiwen
    HELIYON, 2024, 10 (07)
  • [30] Diagnostic Accuracy of CT Fluoroscopy-Guided Needle Aspiration Biopsy of Ground-Glass Opacity Pulmonary Lesions
    Hur, Jin
    Lee, Hye-Jeong
    Nam, Ji Eun
    Kim, Young Jin
    Kim, Tae Hoon
    Choe, Kyu Ok
    Choi, Byoung Wook
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (03) : 629 - 634