Chemical, physical, mineralogical, morphology and leaching characteristics of a thermal power plant air heater washing waste

被引:0
|
作者
Saeedi, M. [1 ]
Amini, H. R. [1 ]
机构
[1] Iran Univ Sci & Technol, Dept Hydraul & Environm, Water & Environm Res Lab, Tehran, Iran
关键词
power plant; waste; heavy metals; leaching test; characterization;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Most of electricity is generated by thermal power plants in Iran. Shahid Rajaee thermal power plant consists of four 250MW natural gas and fuel oil burning units that is located at 100 kin west off Tehran. As a result of fuel oil burning in winter time, boilers air heaters are washed and cleaned frequently. The wastewater originating from air heater washing contains suspended solids and different dissolved heavy metals particularly V, Ni, Zn, Cr, Pb. Wastewater is then treated in effluent treatment plant by chemical precipitation followed by centrifugal dewatering of sludge. Waste from this process contains significant amounts of heavy metals and is considered as specific industrial wastes that should be more characterized under specific wastes act of Iran. For the first time in Iran, in the present investigation seven composite samples from air heater washing wastewater treatment dewatered sludge were subjected to chemical composition, mineralogy and leaching characteristics studies to better understand the physical and chemical characteristics of this kind of wastes. Regarding fuel oil constituents and environmental impacts of metals the most likely pollutants which would be of concern in this study were heavy metals (Cd, Co, Cr, Mn, Ni, Pb, Zn and V). Results revealed that mean pH, wet and dry density and moisture content of the waste are 6.31, 1532 kg/m(3), 1879 kg/m(3) and 15.35 % respectively. Magnetite, SiO2, P2O5, CaO, Al2O3 and MgO were the main constituents of the waste with the weigh percent order of 68.88, 5.91, 3.39, 2.64, 2.59 and 1.76% respectively. Toxicity Characteristic Leaching Procedure (TCLP) test results for some heavy metals showed that mean elemental concentrations of Cd, Co, Cr, Mn, Ni, Pb, V and Zn in leachate were 0.06, 1.55, 5.49, 36.32, 209. 10 0.58, 3 14.06 and 24.84 mg/lit respectively. According to specific wastes act of Iran this waste can be classified as hazardous due to presence of heavy metals and leaching characteristics and should be disposed regarding hazardous waste disposal considerations.
引用
收藏
页码:74 / 79
页数:6
相关论文
共 40 条
  • [21] Physical-chemical properties and structure of foamed slag glass based on thermal power plant wastes
    E. A. Yatsenko
    V. A. Smolii
    A. S. Kosarev
    E. B. Dzyuba
    I. S. Grushko
    B. M. Gol’tsman
    Glass and Ceramics, 2013, 70 : 3 - 6
  • [22] Fascinating physical-chemical properties and fiber morphology of selected waste plant leaves as potential pulp and paper making agents
    Moriam Dasola Adeoye
    Abdulazeez Tunbosun Lawal
    Abibat Opeyemi Jimoh
    Alabi Kazeem Adelani
    Owolabi Opeyemi Ojo
    Nelly Acha Ndukwe
    Taofeek Salaudeen
    Sheriff Adewuyi
    Biomass Conversion and Biorefinery, 2021, 11 : 3061 - 3070
  • [23] Fascinating physical-chemical properties and fiber morphology of selected waste plant leaves as potential pulp and paper making agents
    Adeoye, Moriam Dasola
    Lawal, Abdulazeez Tunbosun
    Jimoh, Abibat Opeyemi
    Adelani, Alabi Kazeem
    Ojo, Owolabi Opeyemi
    Ndukwe, Nelly Acha
    Salaudeen, Taofeek
    Adewuyi, Sheriff
    BIOMASS CONVERSION AND BIOREFINERY, 2021, 11 (06) : 3061 - 3070
  • [24] Chemical, Leaching, and Toxicity Characteristics of Coal Ashes from Circulating Fluidized Bed of a Philippine Coal-Fired Power Plant
    Gallardo, Susan
    van Hullebusch, Eric D.
    Pangayao, Denvert
    Mari Salido, Beatice
    Ronquillo, Ria
    WATER AIR AND SOIL POLLUTION, 2015, 226 (09):
  • [25] Chemical, Leaching, and Toxicity Characteristics of Coal Ashes from Circulating Fluidized Bed of a Philippine Coal-Fired Power Plant
    Susan Gallardo
    Eric D. van Hullebusch
    Denvert Pangayao
    Beatice Mari Salido
    Ria Ronquillo
    Water, Air, & Soil Pollution, 2015, 226
  • [26] POD-based modeling on thermal-flow characteristics for air-cooled condenser of power plant
    Hu, Hemin
    Du, Xiaoze
    Yang, Lijun
    Zhou, Yingyan
    Yang, Yongping
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 76 : 273 - 281
  • [27] Experimental investigation on thermal flow field characteristics of a direct air-cooled system for a large power plant
    Zhao, Wanli
    Liu, Peiqing
    Yingyong Jichu yu Gongcheng Kexue Xuebao/Journal of Basic Science and Engineering, 2009, 17 (04): : 605 - 613
  • [28] Assessment of the Slagging Tendency in Power Plant Boiler Furnaces Depending on the Physical-Chemical Characteristics of Ash and Coal
    Chernov, S. L.
    Prokhorov, V. B.
    Pay, A. V.
    Aparov, V. D.
    PROBLEMELE ENERGETICII REGIONALE, 2023, (04): : 71 - 85
  • [29] Leaching characteristics of fly ash from fluidized bed combustion thermal power plant: Case study: Can (Canakkale-Turkey)
    Baba, Alper
    Gurdal, Gulbin
    Sengunalp, Fatma
    FUEL PROCESSING TECHNOLOGY, 2010, 91 (09) : 1073 - 1080
  • [30] Thermal stability, chemical speciation and leaching characteristics of hazardous trace elements in FGD gypsum from coal-fired power plants
    Zhao, Shilin
    Duan, Yufeng
    Lu, Jincheng
    Gupta, Rajender
    Pudasainee, Deepak
    Liu, Shuai
    Liu, Meng
    Lu, Jianhong
    FUEL, 2018, 231 : 94 - 100