Effective determination of trace residues of glibenclamide in urine samples using dispersive micro solid-phase extraction and its final detection by chromatographic analysis

被引:12
|
作者
Eilami, Owrang [1 ]
Asfaram, Arash [2 ]
Ghaedi, Mehrorang [3 ]
Goudarzi, Alireza [4 ]
机构
[1] Yasuj Univ Med Sci, Coll Med, Dept Infect Dis & Trop Med, Yasuj, Iran
[2] Yasuj Univ Med Sci, Med Plants Res Ctr, Yasuj, Iran
[3] Univ Yasuj, Dept Chem, Yasuj 7591874831, Iran
[4] Golestan Univ, Dept Polymer Engn, Gorgan 4918888369, Iran
关键词
LIQUID-LIQUID MICROEXTRACTION; MOLECULARLY IMPRINTED POLYMER; QUANTITATIVE-DETERMINATION; HUMAN PLASMA; HPLC METHOD; PRECONCENTRATION; NANOPARTICLES; WATER; GLIMEPIRIDE; ADSORPTION;
D O I
10.1039/c8ay01965g
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An analytical procedure for rapid and effective dispersive micro-solid-phase extraction (DMSPE) of glibenclamide (GB) from urine samples was set up by using sulfur doped tin oxide nanoparticles (S@ SnO2-NPs) loaded on activated carbon (AC), as the sorbent, and clean-up materials, followed by detection. The main experimental parameters affecting the extraction efficiency for GB were assessed and optimized. The maximum recovery of GB predicted by optimization plots was 98.86%, obtained with 15 mL of water, 250 mL of methanol (as an eluent), pH 8.0, 25 mg of S@ SnO2-NPs-AC, and an extraction time of 2.5 min. Our results indicated that under these optimized extraction conditions, determination coefficients (R-2) of the calibration curves in the range of 0.60-5500 mg L-1 were > 0.991, detection limits (signal-to-noise ratio = 3) were in the range of 0.09-0.16 mg L-1, the average recoveries of spiked GB in urine samples were 95.73-105.50%, and assessed relative standard deviations (RSDs, %) were between 1.15 and 6.84%. The results also demonstrated that the presented method could be suitable for the determination of trace residues of GB in urine samples.
引用
收藏
页码:627 / 634
页数:8
相关论文
共 50 条
  • [41] Graphene as Solid-Phase Extraction Adsorbent for CZE Determination of Sulfonamide Residues in Meat Samples
    Ye, Nengsheng
    Shi, Pengzhi
    Wang, Qian
    Li, Jian
    CHROMATOGRAPHIA, 2013, 76 (9-10) : 553 - 557
  • [42] Trace and ultratrace determination of heavy metal ions by energy-dispersive X-ray fluorescence spectrometry using graphene as solid sorbent in dispersive micro solid-phase extraction
    Kocot, Karina
    Sitko, Rafal
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2014, 94-95 : 7 - 13
  • [43] Liquid chromatographic determination of novel aminithiazolecarboxamide fungicide residues in soil and crops using online solid-phase extraction
    Kim, BH
    Ok, JH
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2004, 42 (07) : 366 - 370
  • [44] Simultaneous determination of raloxifene and tamoxifen using dispersive micro solid-phase extraction and HPLC method in real water, human hair and serum samples
    Rezaei, Faezeh
    Masrournia, Mahboubeh
    Pordel, Mehdi
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2022, 104 (17) : 5045 - 5064
  • [45] Improvement of ethyl glucuronide determination in human urine and serum samples by solid-phase extraction
    Janda, I
    Alt, A
    JOURNAL OF CHROMATOGRAPHY B, 2001, 758 (02): : 229 - 234
  • [46] Green Dispersive Micro Solid-Phase Extraction using Multiwalled Carbon Nanotubes for Preconcentration and Determination of Cadmium and Lead in Food, Water, and Tobacco Samples
    Gouda, Ayman A.
    Amin, Ali H.
    Ali, Ibrahim S.
    Al Malah, Zakia
    CURRENT ANALYTICAL CHEMISTRY, 2020, 16 (04) : 381 - 392
  • [47] Micro-solid phase extraction of ochratoxin A, and its determination in urine using capillary electrophoresis
    Tien Ping Lee
    Bahruddin Saad
    Baharuddin Salleh
    Ishak Mat
    Microchimica Acta, 2013, 180 : 1149 - 1156
  • [48] Micro-solid phase extraction of ochratoxin A, and its determination in urine using capillary electrophoresis
    Lee, Tien Ping
    Saad, Bahruddin
    Salleh, Baharuddin
    Mat, Ishak
    MICROCHIMICA ACTA, 2013, 180 (11-12) : 1149 - 1156
  • [49] Sample Cleanup Using Solid-Phase Dispersive Extraction for Determination of Vancomycin in Serum
    Sakamoto, Yasuhiro
    Jinno, Yuki
    Shinodzuka, Ikumi
    Iwasaki, Yusuke
    Ito, Rie
    Saito, Koichi
    ANALYTICAL SCIENCES, 2014, 30 (02) : 271 - 275
  • [50] GAS-CHROMATOGRAPHIC ANALYSIS OF METHADONE IN URINE SAMPLES AFTER SOLID-PHASE MICROEXTRACTION