Performance analysis on a multi-type inverter air conditioner

被引:115
|
作者
Park, YC [1 ]
Kim, YC [1 ]
Min, MK [1 ]
机构
[1] Korea Univ, Dept Mech Engn, Sungbuk Gu, Seoul 136701, South Korea
关键词
multi-type air conditioner; variable speed compressor; electric expansion valve; load ratio;
D O I
10.1016/S0196-8904(00)00147-3
中图分类号
O414.1 [热力学];
学科分类号
摘要
An analysis was conducted for a multi-type inverter air conditioner with a linear electronic valve as the expansion device and a variable speed compressor. The system performance was analyzed with variations of operating frequency of the compressor, cooling load imposed on the system and cooling load fraction (i.e. load ratio) between rooms in which is installed an evaporator. The optimum opening of the electric expansion valve (EEV) was calculated when the compressor operating frequency was specified at a given cooling load. As compressor operating frequency increased with cooling load increment, the EEV should have adjusted to get wide openings to get an optimum COP of the system. While total cooling load of the system was constant, the cooling load fraction changed due to the cooling load differences between each room in the multi-type air conditioning system with a number of evaporators and EEVs. The operating frequency of the compressor was increased with increment of the load ratio, and consequently, the power consumption of the compressor increased. The increment of the load ratio, which means increasing the load difference between each room, causes a reduction of the system performance (COP), although the total cooling capacity was constant. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1607 / 1621
页数:15
相关论文
共 50 条
  • [1] Experimental Study of the Controlling Characteristics of Inverter-Driven Multi-type Air Conditioner
    金纪峰
    陈江平
    陈芝久
    [J]. Journal of Shanghai Jiaotong University(Science), 2004, (04) : 52 - 56
  • [2] Development and testing of a multi-type air conditioner without using AC inverters
    Hu, SC
    Yang, RH
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (03) : 373 - 383
  • [3] Dynamic performance analysis of inverter-driven split air conditioner
    Elsayed, Amr Owes
    Kayed, T. S.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 118 : 443 - 452
  • [4] Evaluation of Annual Performance of Multi-type Air-conditioners for Buildings
    Watanabe, Choyu
    Ohashi, Ei-ichiro
    Hirota, Masafumi
    Nagamatsu, Katsuaki
    Nakayama, Hiroshi
    [J]. JOURNAL OF THERMAL SCIENCE AND TECHNOLOGY, 2009, 4 (04): : 483 - 493
  • [5] INVERTER CONTROLS HOME AIR CONDITIONER
    COHEN, C
    [J]. ELECTRONICS, 1982, 55 (05): : 86 - &
  • [6] An influence of air volume flow rate and temperature set point on performance of inverter split-type air-conditioner
    N. Rachapradit
    S. Thepa
    V. Monyakulb
    [J]. Experimental Techniques, 2012, 36 : 18 - 25
  • [7] An Influence of Air Volume Flow Rate and Temperature Set Point on Performance of Inverter Split-Type Air-Conditioner
    Rachapradit, N.
    Thepa, S.
    Monyakulb, V.
    [J]. EXPERIMENTAL TECHNIQUES, 2012, 36 (04) : 18 - 25
  • [8] A Queueing Analysis of Multi-type Servers and Multi-type Customers System based on Gas Stations
    Machida, Yoshito
    Phung-Duc, Tuan
    [J]. PROCEEDINGS OF THE 11TH INTERNATIONAL CONFERENCE ON OPERATIONS RESEARCH AND ENTERPRISE SYSTEMS (ICORES), 2021, : 145 - 152
  • [9] Inverter air-conditioner power system with low power dissipation type
    Park, YJ
    Mun, SP
    Kim, YM
    Lee, HW
    Shu, KY
    [J]. ICEMS 2003: PROCEEDINGS OF THE SIXTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND SYSTEMS, VOLS 1 AND 2, 2003, : 423 - 426
  • [10] On multi-type Cannings models and multi-type exchangeable coalescents
    Moehle, Martin
    [J]. THEORETICAL POPULATION BIOLOGY, 2024, 156 : 103 - 116