Experimental and Monte Carlo analyses of a-Se and CsI:Na/a-Se for X-ray imaging

被引:0
|
作者
Choi, JY [1 ]
Park, JK [1 ]
Kang, SS [1 ]
Kim, JY [1 ]
Lee, KH [1 ]
Im, JG [1 ]
Nam, SH [1 ]
机构
[1] Inje Univ, Dept Biomed Engn, Radiat Image Lab, Kimhae, South Korea
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In this paper, the pertinence of a solution using thin coplanar selenium as a photosensitive converter requiting only a few tens of volts of bias, associated with a thick columnar coating of sodium-doped cesium iodide scintillator, was evaluated. A new evaporation process for direct CsI:Na deposition on an a-Se layer substrate was developed. The photoluminescence characterization of this scintillator shows a light emission peak centered at 420 nm, as expected, which matches the sensitivity spectrum of selenium. In addition, to optimize the thickness of the CsI:Na/a-Se structure, the X-ray absorption was investigated at various diagnostic X-ray energy levels using the MCNP 4C code. The Monte Carlo simulation results showed that the absorption fraction of 500 mu m-Se film and 180 mu m-CsI(Na) film is about 80% at 60 kVp. The simulation results were verified by comparing these with experimental measurements and results. The measured dark currents were below 300 pA/cm(2) at an electric field of 10 V/mu m for a-Se and CsI:Na/a-Se. The preliminary sensitivity measurements give a signal in the range of about 7.31 and 3.95 nC/cm(2)/mR for 180 mu m-CsI:Tl/a-Se and 500 mu m-Se at the exposure conditions of 60 kVp and 2-mm aluminum filter, respectively.
引用
下载
收藏
页码:4501 / 4505
页数:5
相关论文
共 50 条
  • [41] X-Ray Detection Using a Two-Transistor Active Pixel Sensor Array Coupled to an a-Se X-Ray Photoconductor
    Taghibakhsh, Farhad
    Karim, Karim S.
    Belev, George
    Kasap, Safa O.
    IEEE SENSORS JOURNAL, 2009, 9 (1-2) : 51 - 56
  • [42] Review X-ray photoconductors and stabilized a-Se for direct conversion digital flat-panel X-ray image-detectors
    S. O. Kasap
    J. A. Rowlands
    Journal of Materials Science: Materials in Electronics, 2000, 11 : 179 - 198
  • [43] Development and evaluation of a-Se and CdTe flat-panel X-ray detectors for digital radiography and fluoroscopy
    Adachi, S
    Sato, K
    Uehara, K
    Izumi, Y
    Nagata, H
    Yamada, S
    RADIOLOGY, 1999, 213P : 234 - 234
  • [44] Charge transport and electron-hole-pair creation energy in stabilized a-Se x-ray photoconductors
    Haugen, C
    Kasap, SO
    Rowlands, J
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1999, 32 (03) : 200 - 207
  • [45] Spatial and temporal image characteristics of a real-time large area a-Se x-ray detector
    Tousignant, O
    Demers, Y
    Laperrière, L
    Mani, H
    Gauthier, P
    Leboeuf, J
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 207 - 215
  • [46] Investigation of a-Se detector for imaging applications under radiotherapy environment
    Fang, G
    Pearson, D
    Harper, B
    Schmidt, R
    Spence, D
    Olivera, G
    Mackie, R
    Rowlands, J
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2329 - 2333
  • [47] Evaluation of a-Se nanostructure morphology by differential evanescent light imaging
    Aaronov, S.
    Ganon, E.
    Okhman, P.
    Gankin, M.
    Mirchin, N.
    Popescu, S. A.
    Lapsker, I.
    Peled, A.
    JOURNAL OF NANOPHOTONICS, 2009, 3
  • [48] Performance of a Prototype Amorphous Silicon Active Pixel Sensor Array using a-Se for Direct X-ray Conversion
    Izadi, M. H.
    Tousignant, O.
    Mokam, M. Feuto
    Yazdandoost, M.
    Safavian, N.
    Mani, H.
    Laperriere, L.
    Karim, K. S.
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [49] Dependence of the electrical properties of stabilized a-Se on the preparation conditions and the development of a double layer X-ray detector structure
    Belev, George
    Kasap, Safa
    Rowlands, J. A.
    Hunter, David
    Yaffe, Martin
    CURRENT APPLIED PHYSICS, 2008, 8 (3-4) : 383 - 387
  • [50] Charge collection and absorption-limited sensitivity of x-ray photoconductors:: Applications to a-Se and HgI2
    Kabir, MZ
    Kasap, SO
    APPLIED PHYSICS LETTERS, 2002, 80 (09) : 1664 - 1666