Comparison of point-of-care and laboratory glucose analysis in critically ill patients

被引:0
|
作者
Lacara, Teresita [1 ]
Domagtoy, Caroline [1 ]
Lickliter, Donna [1 ]
Quattrocchi, Kathy [1 ]
Snipes, Lydia [1 ]
Kuszaj, Joanne [1 ]
Prasnikar, MaryClare [1 ]
机构
[1] Rex Healthcare, Intens Care Unit, Raleigh, NC 27607 USA
关键词
D O I
暂无
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background Blood for point-of-care analysis of glucose levels is often obtained from different sources (fingerstick, arterial or central venous catheter). Objectives To examine agreement between point-of-care and laboratory glucose values and to determine effects of hematocrit, serum carbon dioxide, and mean arterial pressure on the accuracy of point-of-care values. Methods Point-of-care values were compared with laboratory values. In 49 critically ill patients, blood was obtained first from a catheter for laboratory testing and then from the catheter and via fingerstick for point-to-care testing. Bias, precision, and root-mean-square differences were calculated to quantify differences in values between the 2 methods. A t test was used to determine differences in values between each point-of-care blood source and the laboratory value. Multiple regression analysis was used to determine if serum level of carbon dioxide, hematocrit, and/or mean arterial pressure significantly contributed to the difference in bias and precision for the point-of-care blood sources. Results Mean laboratory glucose level was 135 (SEM 5.3, range 58-265) mg/dL. In point-of-care testing, bias +/- precision and root-mean-square differences were 2.1 +/- 12.3 and 12.35 respectively, for fingerstick blood and 0.6 +/- 10.6 and 10.46 for catheter blood. Values for point-of-care and laboratory tests did not differ significantly. For catheter samples, hematocrit and serum carbon dioxide contributed significantly to difference scores between point-of-care and laboratory values (P < .001). Conclusions Glucose values for point-of-care samples did not differ significantly from laboratory values. For catheter samples, hematocrit and serum carbon dioxide levels accounted for the difference between point-of-care and laboratory glucose values.
引用
收藏
页码:336 / 346
页数:11
相关论文
共 50 条
  • [1] COMPARISON OF GLUCOSE POINT-OF-CARE VALUES WITH LABORATORY VALUES IN CRITICALLY ILL PATIENTS
    Shearer, Anna
    Boehmer, Marilyn
    Closs, Melanie
    Dela Rosa, Rosalina
    Hamilton, Jean
    Horton, Karen
    McGrath, Rose
    Schulman, Christine
    [J]. AMERICAN JOURNAL OF CRITICAL CARE, 2009, 18 (03) : 224 - 230
  • [2] POINT-OF-CARE GLUCOSE TESTING IN CRITICALLY ILL PATIENTS
    Scimio, Kylie
    Carter, Chris
    El-Oshar, Seraj
    [J]. CRITICAL CARE MEDICINE, 2018, 46 (01) : 202 - 202
  • [3] DIFFERENCES IN GLUCOSE VALUES OBTAINED FROM POINT-OF-CARE GLUCOSE METERS AND LABORATORY ANALYSIS IN CRITICALLY ILL PATIENTS
    Cook, Anjannette
    Laughlin, Delyla
    Moore, Margery
    North, Doreen
    Wilkins, Kathleen
    Wong, Gay
    Wallace-Scroggs, Allyson
    Halvorsen, Lisa
    [J]. AMERICAN JOURNAL OF CRITICAL CARE, 2009, 18 (01) : 65 - 71
  • [4] Clinical Reliability of Point-of-Care Glucose Testing in Critically Ill Patients
    Pilackas, Kylie
    El-Oshar, Seraj
    Carter, Chris
    [J]. JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2020, 14 (01): : 65 - 69
  • [5] GLUCOSE LEVELS IN CRITICALLY ILL PATIENTS: POINT-OF-CARE (POC) TESTING VERSUS CENTRAL LABORATORY VALUES
    Arce-Delgado, S.
    Bernat-Adell, A.
    Blanch-Eixarch, F.
    Ferrandiz-Selles, A.
    Guillamon-Navarro, S.
    Mateu-Campos, L.
    DeLeon-Belmar, J.
    [J]. INTENSIVE CARE MEDICINE, 2010, 36 : S219 - S219
  • [6] Point-of-Care Testing in Critically Ill Patients
    Fries, Dietmar
    Streif, Werner
    [J]. SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2015, 41 (01): : 75 - 83
  • [7] Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients
    Corstjens, Anouk M.
    Ligtenberg, Jack J. M.
    van der Horst, Iwan C. V.
    Spanjersberg, Rob
    Lind, Joline S. W.
    Tulleken, Jaap E.
    Meertens, John H. J. M.
    Zijlstra, Jan G.
    [J]. CRITICAL CARE, 2006, 10 (05):
  • [8] Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients
    Anouk M Corstjens
    Jack JM Ligtenberg
    Iwan CC van der Horst
    Rob Spanjersberg
    Joline SW Lind
    Jaap E Tulleken
    John HJM Meertens
    Jan G Zijlstra
    [J]. Critical Care, 10
  • [9] Point-of-Care Lung Ultrasound in Critically ill Patients
    Shrestha, Gentle S.
    Weeratunga, Dameera
    Baker, Kylie
    [J]. REVIEWS ON RECENT CLINICAL TRIALS, 2018, 13 (01) : 15 - 26
  • [10] CLINICAL IMPACT OF ACCURATE POINT-OF-CARE GLUCOSE MONITORING IN CRITICALLY ILL ADULT PATIENTS
    Caynak, Rachel
    Lima, Kelly
    Steele, Amanda
    Tran, Nam
    [J]. CRITICAL CARE MEDICINE, 2016, 44 (12)