Calorimetric determination of kQ factors for NE 2561 and NE 2571 ionization chambers in 5 cm x 5 cm and 10 cm x 10 cm radiotherapy beams of 8 MV and 16 MV photons

被引:30
|
作者
Krauss, Achim [1 ]
Kapsch, Ralf-Peter [1 ]
机构
[1] Phys Tech Bundesanstalt, D-38116 Braunschweig, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2007年 / 52卷 / 20期
关键词
D O I
10.1088/0031-9155/52/20/011
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The relative uncertainty of the ionometric determination of the absorbed dose to water, D-w, in the reference dosimetry of high-energy photon beams is in the order of 1.5% and is dominated by the uncertainty of the calculated chamber- and energy-dependent correction factors k(Q). In the present investigation, k(Q) values were determined experimentally in 5 cm x 5 cm and 10 cm x 10 cm radiotherapy beams of 8 MV and 16 MV bremsstrahlung by means of a water calorimeter operated at 4 degrees C. Ionization chambers of the types NE 2561 and NE 2571 were calibrated directly in the water phantom of the calorimeter. The measurements were carried out at the linear accelerator of the Physikalisch-Technische Bundesanstalt. It is shown that the k(Q) factor of a single ionization chamber can be measured with a standard uncertainty of less than 0.3%. No significant variations of k(Q) were found for the different lateral sizes of the radiation fields used in this investigation.
引用
收藏
页码:6243 / 6259
页数:17
相关论文
共 38 条
  • [1] Calorimetric determination of kQ factors for NE 2561 and NE 2571 ionization chambers in 5 cm x 5 cm and 10 cm x 10 cm radiotherapy beams of 8 MV and 16 MV photons (vol 52, pg 6243, 2007)
    Krauss, Achim
    Kapsch, Ralf-Peter
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (04): : 1151 - 1152
  • [2] Experimental determination of kQ factors for cylindrical ionization chambers in 10 cm x 10 cm and 3 cm x 3 cm photon beams from 4 MV to 25 MV
    Krauss, A.
    Kapsch, R. P.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (15): : 4227 - 4246
  • [3] Absorbed dose beam quality correction factors kQ for the NE2571 chamber in a 5 MV and a 10 MV photon beam
    Palmans, H
    Mondelaers, W
    Thierens, H
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (03): : 647 - 663
  • [5] Variation of Beam Quality Correction Factor with Time: Cases for Ne2571 and Ne2581 Chambers in the 6 and 10 Mv X-Rays Beams
    Samat, S. B.
    Too, S. X.
    Kadni, T.
    Dolah, M. T.
    SAINS MALAYSIANA, 2009, 38 (02): : 203 - 207
  • [6] An Isolated Three-Port DC-DC Converter with High Power Density in 10 cm x 5 cm x 0.8 cm Card Size for Flexible Automotive Systems
    Inoue, Shuntaro
    Itoh, Kenichi
    Ishigaki, Masanori
    Sugiyama, Takahide
    Sugai, Masaru
    2016 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2016,
  • [7] Off-axis dose perturbation effects in water in a 5 x 5 cm2 18 MV photon beam for the PTW microLion and Exradin AlSL ionization chambers
    O'Grady, K.
    Davis, S. D.
    Papaconstadopoulos, P.
    Seuntjens, J.
    MEDICAL PHYSICS, 2014, 41 (08) : 11 - 11
  • [8] A laser system producing 5x10(19)W/cm(2) at 10 Hz
    Antonetti, A
    Blasco, F
    Chambaret, JP
    Cheriaux, G
    Darpentigny, G
    LeBlanc, C
    Rousseau, P
    Ranc, S
    Rey, G
    Salin, F
    APPLIED PHYSICS B-LASERS AND OPTICS, 1997, 65 (02): : 197 - 204
  • [9] EXCITON LUMINESCENCE OF SILICON DOPED WITH PHOSPHORUS AND GALLIUM IN CONCENTRATIONS OF 5X10(16)-3X10(17) CM-3
    GORBUNOV, MV
    KAMINSKII, AS
    SOVIET PHYSICS SEMICONDUCTORS-USSR, 1989, 23 (02): : 221 - 223
  • [10] Cavity ring down spectroscopy with 5 x 10-13 cm-1 sensitivity
    Kassi, Samir
    Campargue, Alain
    JOURNAL OF CHEMICAL PHYSICS, 2012, 137 (23):