Quantitative Analysis and Quality Assurance (QA) of Gynecological Brachytherapy Applicators Using Radiochromic Film Dosimetry

被引:0
|
作者
Aldelaijan, S. [1 ,2 ,3 ]
Khouj, Y. [1 ]
Khosravi, M. [1 ]
Harris, T. [1 ]
O'Farrell, D. [1 ]
Jacobson, M. [1 ]
Seuntjens, J. [2 ]
Devic, S. [2 ,4 ]
Buzurovic, I. [1 ]
机构
[1] Harvard Med Sch, Dana Farber Canc Inst, Brigham & Womens Hosp, Boston, MA 02115 USA
[2] McGill Univ, Montreal, PQ, Canada
[3] King Faisal Specialist Hosp & Res Ctr, Riyadh, Saudi Arabia
[4] Jewish Gen Hosp, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PO-GeP-T-6
引用
收藏
页码:E838 / E838
页数:1
相关论文
共 50 条
  • [1] A Novel Source Tracking Method for Accurate and Comprehensive HDR Brachytherapy Quality Assurance Using Radiochromic Film Dosimetry
    Aldelaijan, S.
    Papaconstadopoulos, P.
    Bekerat, H.
    Schneider, J.
    Seuntjens, J.
    Buzurovic, I.
    Devic, S.
    MEDICAL PHYSICS, 2018, 45 (06) : E572 - E572
  • [2] Positional and angular tracking of HDR 192Ir source for brachytherapy quality assurance using radiochromic film dosimetry
    Aldelaijan, Saad
    Devic, Slobodan
    Bekerat, Hamed
    Papaconstadopoulos, Pavlos
    Schneider, James
    Seuntjens, Jan
    Cormack, Robert A.
    Buzurovic, Ivan M.
    MEDICAL PHYSICS, 2020, 47 (12) : 6122 - 6139
  • [3] Radiochromic film based patient specific QA for brachytherapy
    Devic, S.
    Asgharizadeh, S.
    Syme, A.
    DeBlois, F.
    Seuntjens, J.
    El Naqa, I.
    Bekerat, H.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S152 - S152
  • [4] High dose-rate brachytherapy source position quality assurance using radiochromic film
    Evans, M. D. C.
    Devic, S.
    Podgorsak, E. B.
    MEDICAL DOSIMETRY, 2007, 32 (01) : 13 - 15
  • [5] Use of GafChromic dosimetry film for HDR brachytherapy for quality assurance
    Steidley, KD
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 3, 1996, : C504 - C504
  • [6] Towards informed and digitized HDR brachytherapy QA: Quantitative analysis of GYN applicators
    Aldelaijan, S.
    Khosravi, M.
    Khouj, Y.
    Harris, T.
    O'Farrell, D.
    Seuntjens, J.
    Devic, S.
    Buzurovic, I.
    RADIOTHERAPY AND ONCOLOGY, 2021, 158 : S190 - S192
  • [7] Radiochromic film dosimetry for a new electronic brachytherapy source
    Chiu-Tsao, S
    Rusch, T
    Axelrod, S
    Tsao, H
    Harrison, L
    MEDICAL PHYSICS, 2004, 31 (06) : 1913 - 1913
  • [8] Implementation of a Novel HDR Source Tracking Model for Source Quality Assurance Using Radiochromic Film Dosimetry
    Aldelaijan, S.
    Devic, S.
    Bekerat, H.
    Papaconstadopoulos, P.
    Schneider, J.
    Seuntjens, J.
    Cormack, R.
    Buzurovic, I.
    MEDICAL PHYSICS, 2020, 47 (06) : E366 - E366
  • [9] A prototype quantitative film scanner for radiochromic film dosimetry
    Ranade, Manisha K.
    Li, Jonathan G.
    Dubose, Ryan S.
    Kozelka, Jakub
    Simon, William E.
    Dempsey, James F.
    MEDICAL PHYSICS, 2008, 35 (02) : 473 - 479
  • [10] In vivo dosimetry of high dose rate brachytherapy using an improved radiochromic film
    Parsai, E
    Feldmeier, J
    Ye, S
    MEDICAL PHYSICS, 2002, 29 (06) : 1206 - 1206