In-Stent Thrombosis and Stenosis After Neck-Remodeling Device-Assisted Coil Embolization of Intracranial Aneurysms

被引:49
|
作者
Kanaan, Hilal [1 ]
Jankowitz, Brian [1 ]
Aleu, Aitziber [1 ,5 ]
Kostov, Dean [1 ]
Lin, Ridwan [2 ]
Lee, Kimberly [1 ]
Panipitiya, Narendra [1 ]
Gologorsky, Yakov [4 ]
Sandhu, Emir [1 ]
Rissman, Lauren [1 ]
Crago, Elizabeth [1 ]
Chang, Yue-Fang [1 ]
Kim, Seong-Rim [1 ,3 ]
Jovin, Tudor [2 ]
Horowitz, Michael [1 ]
机构
[1] Univ Pittsburgh, Med Ctr, Dept Neurosurg, Pittsburgh, PA 15206 USA
[2] Univ Pittsburgh, Med Ctr, Dept Neurol, Pittsburgh, PA 15206 USA
[3] Catholic Univ Korea, Holy Family Hosp, Dept Neurosurg, Seoul, South Korea
[4] Mt Sinai Sch Med, Dept Neurosurg, New York, NY USA
[5] Univ Autonoma Barcelona, Dept Neurol, E-08193 Barcelona, Spain
关键词
Aneurysm; Coil; In-stent stenosis; Neck-remodeling device; Stent; Stent-assisted coiling; Stent-coil; STRATEGIES;
D O I
10.1227/NEU.0b013e3181f8d194
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Intrinsic thrombosis and stenosis are complications associated with the use of neck-remodeling devices in the treatment of intracranial aneurysms. OBJECTIVE: To examine the technical and anatomic factors that predict short-and long-term stent patency. METHODS: We undertook a retrospective review of 161 patients who underwent coil embolization of 168 ruptured and unruptured aneurysms assisted by the use of a neck-remodeling device. One hundred twenty-seven patients had catheter-based angiographic follow-up to evaluate 133 stent-coil constructs (mean, 15.4 months; median, 12.7 months). The technique of microcatheter jailing was used in a majority of patients; nonstandard stent configurations were also used. RESULTS: Clinical follow-up for all patients who had catheter-based angiograms demonstrated that among 133 stent constructs, a total of 9 (6.8%) had an in-stent event: 6 acute or subacute thrombosis (4.5%) and 3 delayed stenosis or occlusion (2.3%). Seven of these constructs were associated with a symptomatic event (5.3%). A significantly higher rate of in-stent events was seen with the use of constructs to treat anterior communicating artery aneurysms. When all patients are considered, including those who did not receive catheter-based follow-up imaging, 2 of 168 procedures (1.2%) resulted in the death of a patient, and procedural morbidity was 14.9%. CONCLUSION: From these results and those in the published literature, in-stent complication rates are low in carefully selected patients. The use of dual antiplatelet therapy, sensitivity assays, and glycoprotein IIb/IIIa inhibitors may decrease the rate of acute and chronic in-stent complications.
引用
收藏
页码:1523 / 1532
页数:10
相关论文
共 50 条
  • [31] Stent-Assisted Coil Embolization of Intracranial Aneurysms: Complications in Acutely Ruptured versus Unruptured Aneurysms
    Bechan, R. S.
    Sprengers, M. E.
    Majoie, C. B.
    Peluso, J. P.
    Sluzewski, M.
    van Rooij, W. J.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2016, 37 (03) : 502 - 507
  • [32] Multicenter Postmarket Analysis of the Neuroform Atlas Stent for Stent-Assisted Coil Embolization of Intracranial Aneurysms
    Burkhardt, J. -K.
    Srinivasan, V.
    Srivatsan, A.
    Albuquerque, F.
    Ducruet, A. F.
    Hendricks, B.
    Gross, B. A.
    Jankowitz, B. T.
    Thomas, A. J.
    Ogilvy, C. S.
    Maragkos, G. A.
    Enriquez-Marulanda, A.
    Crowley, R. W.
    Levitt, M. R.
    Kim, L. J.
    Griessenauer, C. J.
    Schirmer, C. M.
    Dalal, S.
    Piper, K.
    Mokin, M.
    Winkler, E. A.
    Abla, A. A.
    McDougall, C.
    Birnbaum, L.
    Mascitelli, J.
    Litao, M.
    Tanweer, O.
    Riina, H.
    Johnson, J.
    Chen, S.
    Kan, P.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2020, 41 (06) : 1037 - 1042
  • [33] Contour device implantation versus coil embolization for treatment of narrow neck intracranial aneurysms
    Karim Mostafa
    Fernando Bueno Neves
    Friederike Gärtner
    Sönke Peters
    Johannes Hensler
    Naomi Larsen
    Tristan Klintz
    Justus Mahnke
    Olav Jansen
    Fritz Wodarg
    Scientific Reports, 13
  • [34] Contour device implantation versus coil embolization for treatment of narrow neck intracranial aneurysms
    Mostafa, Karim
    Neves, Fernando Bueno
    Gaertner, Friederike
    Peters, Soenke
    Hensler, Johannes
    Larsen, Naomi
    Klintz, Tristan
    Mahnke, Justus
    Jansen, Olav
    Wodarg, Fritz
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [35] Relationship between Angiographic Results and Morphology in Sidewall Intracranial Aneurysms after Stent-Assisted Coil Embolization
    Nii, Kouhei
    Aikawa, Hiroshi
    Tsutsumi, Masanori
    Eto, Ayumu
    Iko, Minoru
    Sakamoto, Kimiya
    Inoue, Ritsuro
    Mitsutake, Takafumi
    Hanada, Hayatsura
    Kazekawa, Kiyoshi
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2016, 25 (03): : 533 - 539
  • [36] Neuroform stent-assisted coil embolization of wide-neck intracranial aneurysms: Strategies in stent deployment and midterm follow-up
    Biondi, Alessandra
    Janardhan, Vallabh
    Katz, Jeffrey M.
    Salvaggio, Kimberly
    Riina, Howard A.
    Gobin, Y. Pierre
    NEUROSURGERY, 2007, 61 (03) : 460 - 468
  • [37] Predictors of recurrence after stent-assisted coil embolization of paraclinoid aneurysms
    Lv, Nan
    Zhao, Rui
    Yang, Pengfei
    Fang, Yibin
    Li, Qiang
    Xu, Yi
    Hong, Bo
    Zhao, Wenyuan
    Liu, Jianmin
    Huang, Qinghai
    JOURNAL OF CLINICAL NEUROSCIENCE, 2016, 33 : 173 - 176
  • [38] Factors associated with in-stent stenosis after cerebral aneurysm embolization using a Pipeline embolization device
    Flores-Milan, Gabriel
    Pressman, Elliot
    Peto, Ivo
    Ren, Zeguang
    Guerrero, Waldo R.
    Mokin, Maxim
    INTERVENTIONAL NEURORADIOLOGY, 2022, 28 (06) : 731 - 736
  • [39] Machine learning to predict in-stent stenosis after Pipeline embolization device placement
    Wei, Dachao
    Deng, Dingwei
    Gui, Siming
    You, Wei
    Feng, Junqiang
    Meng, Xiangyu
    Chen, Xiheng
    Lv, Jian
    Tang, Yudi
    Chen, Ting
    Liu, Peng
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [40] Intracranial hemorrhage associated with stent-assisted coil embolization of cerebral aneurysms: a cautionary report
    Tumialan, Luis M.
    Zhang, Y. Jonathan
    Cawley, C. Michael
    Dion, Jacques E.
    Tong, Frank C.
    Barrow, Daniel L.
    JOURNAL OF NEUROSURGERY, 2008, 108 (06) : 1122 - 1129