A Facile Fabrication of a Potentiometric Arrayed Glucose Biosensor Based on Nafion-GOx/GO/AZO

被引:26
|
作者
Chou, Jung-Chuan [1 ]
Lin, Si-Hong [1 ]
Lai, Tsu-Yang [1 ]
Kuo, Po-Yu [1 ]
Lai, Chih-Hsien [1 ]
Nien, Yu-Hsun [2 ]
Su, Tzu-Yu [2 ]
机构
[1] Natl Yunlin Univ Sci & Technol, Grad Sch Elect Engn, Touliu 64002, Yunlin, Taiwan
[2] Natl Yunlin Univ Sci & Technol, Grad Sch Chem & Mat Engn, Touliu 64002, Yunlin, Taiwan
关键词
glucose; zinc oxide (ZnO); aluminum-doped zinc oxide (AZO); graphene oxide (GO); potentiometric biosensor; arrayed electrodes; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; GRAPHENE OXIDE; THIN-FILM; AL; IMMOBILIZATION; OXIDATION; NANOWIRES; PLATFORM; DEVICES; SENSORS;
D O I
10.3390/s20040964
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, the potentiometric arrayed glucose biosensors, which were based on zinc oxide (ZnO) or aluminum-doped zinc oxide (AZO) sensing membranes, were fabricated by using screen-printing technology and a sputtering system, and graphene oxide (GO) and Nafion-glucose oxidase (GOx) were used to modify sensing membranes by using the drop-coating method. Next, the material properties were characterized by using a Raman spectrometer, a field-emission scanning electron microscope (FE-SEM), and a scanning probe microscope (SPM). The sensing characteristics of the glucose biosensors were measured by using the voltage-time (V-T) measurement system. Finally, electrochemical impedance spectroscopy (EIS) was conducted to analyze their charge transfer abilities. The results indicated that the average sensitivity of the glucose biosensor based on Nafion-GOx/GO/AZO was apparently higher than that of the glucose biosensor based on Nafion-GOx/GO/ZnO. In addition, the glucose biosensor based on Nafion-GOx/GO/AZO exhibited an excellent average sensitivity of 15.44 mV/mM and linearity of 0.997 over a narrow range of glucose concentration range, a response time of 26 s, a limit of detection (LOD) of 1.89 mM, and good reproducibility. In terms of the reversibility and stability, the hysteresis voltages (V-H) were 3.96 mV and 2.42 mV. Additionally, the glucose biosensor also showed good anti-inference ability and reproducibility. According to these results, it is demonstrated that AZO is a promising material, which could be used to develop a reliable, simple, and low-cost potentiometric glucose biosensor.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] The DET glucose biosensor based on GO/MWCNTs nanocomposite
    Feng, Jiyong
    Chang, Shwu-Jen
    Chen, Ching-Jung
    Liu, Jen-Tsai
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 84 - 84
  • [22] AMPEROMETRIC BIOSENSOR FOR GLUCOSE BASED ON NAFION LOADED WITH REDOX COUPLES AND GLUCOSE-OXIDASE
    BELANGER, D
    VAILLANCOURT, M
    FORTIER, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1990, 199 : 1 - ANYL
  • [23] An amperometric glucose biosensor based on a GOx-entrapped TiO2-SWCNT composite
    Nguyen Quoc Dung
    Patil, Dewyani
    Thanh-Tung Duong
    Jung, Hyuck
    Kim, Dojin
    Yoon, Soon-Gil
    SENSORS AND ACTUATORS B-CHEMICAL, 2012, 166 : 103 - 109
  • [24] Electroanalytical biosensor based on GOx/FCA/PEG-modified SWCNT electrode for determination of glucose
    Do Kyoung Han
    Cheng Ai Li
    Sung Ho Song
    Kun Cho
    Jong-Soon Choi
    Seong Eun Son
    Gi Hun Seong
    Journal of Analytical Science and Technology, 14
  • [25] Electroanalytical biosensor based on GOx/FCA/PEG-modified SWCNT electrode for determination of glucose
    Han, Do Kyoung
    Li, Cheng Ai
    Song, Sung Ho
    Cho, Kun
    Choi, Jong-Soon
    Son, Seong Eun
    Seong, Gi Hun
    JOURNAL OF ANALYTICAL SCIENCE AND TECHNOLOGY, 2023, 14 (01)
  • [26] An ultrasensitive biosensor for glucose based on solid-state electrochemiluminescence on GOx/CdS/GCE electrode
    Qiu, Bin
    Miao, Miao
    She, Lishuang
    Jiang, Xiaofen
    Lin, Zhen-yu
    Chen, Guo-nan
    ANALYTICAL METHODS, 2013, 5 (08) : 1941 - 1945
  • [27] A NOVEL POTENTIOMETRIC GLUCOSE BIOSENSOR BASED ON POLYANILINE SEMICONDUCTOR-FILMS
    KARYAKINA, EE
    NEFTYAKOVA, LV
    KARYAKIN, AA
    ANALYTICAL LETTERS, 1994, 27 (15) : 2871 - 2882
  • [28] Research of Stability and Interference With the Potentiometric Flexible Arrayed Glucose Sensor Based on Microfluidic Framework
    Jung-Chuan, Chou
    Jhang, Chiung-Yun
    Yi-Hung, Liao
    Lin, Jyun-Wun
    Chen, Ruei-Ting
    Hsueh-Tao, Chou
    IEEE TRANSACTIONS ON SEMICONDUCTOR MANUFACTURING, 2014, 27 (04) : 523 - 529
  • [29] Electrochemical Fabrication and Application of the Glucose Biosensor Based on Graphene
    Xia Qianfang
    Luo Dan
    Li Zaijun
    ACTA CHIMICA SINICA, 2012, 70 (19) : 2079 - 2084
  • [30] Preparation of a new graphene based biosensor modified with nanoparticles and nafion for the detection of glucose
    Akin, Deniz
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2018, 256