Flash evaporation intensified by microwave energy and performance analysis

被引:6
|
作者
Tian Shihong [1 ,2 ,3 ,4 ]
Ravindra, A. V. [1 ,2 ,3 ,4 ]
Ju Shaohua [1 ,2 ,3 ,4 ]
Peng Jinhui [1 ,2 ]
Zhang Lihua [1 ,2 ,3 ,4 ]
Lei, Guo [1 ,2 ,3 ,4 ]
Ling, Liu Xiao [1 ,2 ,3 ,4 ]
机构
[1] Natl Local Joint Lab Engn Applicat Microwave Ener, Kunming 650093, Yunnan, Peoples R China
[2] Kunming Univ Sci & Technol, Minist Educ, Key Lab Unconvent Met, Kunming 650093, Yunnan, Peoples R China
[3] Yunnan Prov Key Lab Intensificat Met, Kunming 650093, Yunnan, Peoples R China
[4] Kunming Univ Sci & Technol, Fac Met & Energy Engn, Kunming 650093, Yunnan, Peoples R China
关键词
Microwave heating; Energy conversion; Flash evaporation; Vapor-liquid two phase; MULTI EFFECT EVAPORATION; DROPLET EVAPORATION; SPRAY; WATER;
D O I
10.1016/j.applthermaleng.2019.114471
中图分类号
O414.1 [热力学];
学科分类号
摘要
A novel microwave flash evaporation ( MFE) system is presented in this paper for the first time, which is expected to solve the inherent problems of conventional flash evaporation (CFE) system, such as high energy consumption. scaling, and long stages etc. In order to demonstrate the performance of such a novel system, some single factor experiments have been carried out by using water as experimental material, and the influence of parameters such as microwave power, initial temperature, and liquid flow rate have been studied. The results show that the evaporation quantity increases with the increase of microwave power, flow rate, and initial temperature, Under experimental conditions, the better operation condition is achieved at flow-rate of 40 L/h, initial liquid temperature of 50 degrees C, and microwave power of 1.35 kW, the evaporation quantity in the case of MFE is as high as 1.35 L in 20 min, but it is only 0.74 L in 20 min for CFE. The enhanced performance of MFE system is shown by comparing with the CFE system under the same conditions. Moreover, the energy efficiency is calculated and represented by a dimensionless parameter Gain Output Ratio (GOR), and the maximum energy efficiency for MSF system is about 79.38% at the better operation condition.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] CONTROLLED FLASH EVAPORATION
    ROE, RC
    OTHMER, DF
    CHEMICAL ENGINEERING PROGRESS, 1971, 67 (07) : 77 - &
  • [22] Energy and exergy analyses of circulatory flash evaporation of aqueous NaCl solution
    Wang, Yu
    He, Qi
    Yang, Qingzhong
    Zhang, Dan
    Liu, Ming
    Yan, Junjie
    DESALINATION, 2018, 436 : 81 - 90
  • [23] Experimental study on energy transformation and separation characteristic of circulatory flash evaporation
    Zhang, Yousen
    Wang, Jinshi
    Yan, Junjie
    Chong, Daotong
    Liu, Jiping
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2016, 99 : 862 - 871
  • [24] Case study for enhancing concentration of waste dilute sulfuric acid by microwave flash evaporation: modelling, heat transfer, energy consumption and process optimization
    Tian, Shihong
    Guo, Lei
    Ju, Shaohua
    Li, Wei
    Xu, Lei
    Dai, Linqing
    SEPARATION AND PURIFICATION TECHNOLOGY, 2023, 318
  • [25] Experimental study on energy transformation of static liquid pool during flash evaporation
    Singh, Sarvjeet
    Chakraborty, Prodyut R.
    Kothadia, Hardik B.
    APPLIED THERMAL ENGINEERING, 2023, 220
  • [26] SIMPLE FLASH EVAPORATION ATTACHMENT
    TYAGI, RC
    KUMAR, R
    SETHI, VC
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1976, 9 (11): : 938 - 938
  • [27] POWDER DROPPER FOR FLASH EVAPORATION
    DUA, AK
    THATTE, SB
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (12): : 1119 - &
  • [28] Experimental study on energy conversion in static flash evaporation of aqueous NaCl solution
    Yang, Qingzhong
    Zhang, Dan
    Yan, Junjie
    Liang, Ting
    DESALINATION, 2018, 430 : 56 - 63
  • [29] THE GEOTHERMAL FLASH EVAPORATION PROCESS
    AWERBUCH, L
    VANDERMAST, V
    WEEKES, M
    CHEMICAL ENGINEERING PROGRESS, 1985, 81 (02) : 40 - 45
  • [30] DESALTING SEAWATER BY FLASH EVAPORATION
    PEAK, WE