A new technique for in-fixture calibration using standards of constant length

被引:2
|
作者
Wan, CH
Nauwelaers, B
Schreurs, D
De Raedt, W
Van Rossum, M
机构
[1] Katholieke Univ Leuven, Dept Elect Engn, B-3001 Heverlee, Belgium
[2] Inter Univ Microelect Ctr, B-3001 Heverlee, Belgium
关键词
calibration; error compensation; measurement errors; microwave circuits; microwave measurements; millimeter-wave measurements;
D O I
10.1109/22.709480
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a new technique for in-fixture calibration using standards of constant length. The technique uses a through line, reflective load, symmetric two-port at a reference position, and the same two-port at a different position, all produced on substrates of the same electrical properties and physical length. When compared with the through-reflect line (TRL) technique, this one eliminates the need for a length change during calibration and device measurements while retaining comparable accuracy. Moreover, in contrast with the line-network network (LNN) technique, it provides easy resolution of all error coefficients without ambiguities and does not require physical movement of a reference two-port, but reproduction of a reference two-port on microwave integrated circuit (MIC) substrates, which is easy to realize, All these features make the new technique useful for in-fixture measurements requiring a constant distance between input and output connections. The validity of the proposed technique is illustrated by experimental results.
引用
收藏
页码:1318 / 1320
页数:3
相关论文
共 50 条
  • [31] TLP calibration, correlation, standards, and new techniques
    Barth, JE
    Verhaege, K
    Henry, LG
    Richner, J
    IEEE TRANSACTIONS ON ELECTRONICS PACKAGING MANUFACTURING, 2001, 24 (02): : 99 - 108
  • [32] On constant focal length self-calibration from multiple views
    Bocquillon, Benoit
    Bartoli, Adrien
    Gurdjos, Pieffe
    Crouzil, Alain
    2007 IEEE CONFERENCE ON COMPUTER VISION AND PATTERN RECOGNITION, VOLS 1-8, 2007, : 739 - 746
  • [33] Calibration Scheme for Microwave Biosensors using exclusively Liquid Calibration Standards
    Michler, Fabian
    Lenze, Felix
    Schuessler, Martin
    Jakoby, Rolf
    2016 IEEE TOPICAL CONFERENCE ON BIOMEDICAL WIRELESS TECHNOLOGIES, NETWORKS, AND SENSING SYSTEMS (BIOWIRELESS), 2016, : 66 - 69
  • [34] A NEW 6-PORT CALIBRATION METHOD USING 4 STANDARDS AND AVOIDING SINGULARITIES
    GHANNOUCHI, FM
    BOSISIO, RG
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1987, 36 (04) : 1022 - 1027
  • [35] New standards of optical wave-length.
    Kayser, H.
    PHILOSOPHICAL MAGAZINE, 1904, 8 (43-48) : 568 - 571
  • [36] NUCLEAR TRANSITIONS AND NEW STANDARDS OF LENGTH AND TIME
    Alexandrov, V. S.
    Chekirda, K. V.
    Fedorin, V. L.
    Melnikov, N. A.
    Pasternak, A. A.
    Zakharenko, Yu. G.
    ACTA PHYSICA POLONICA B, 2011, 42 (3-4): : 853 - 858
  • [37] SIMPLE TECHNIQUE FOR THE CALIBRATION OF THE WAVE-LENGTH SCALE OF SPECTROPHOTOMETERS
    PARTHASARATHY, NV
    SANGHI, I
    NATURE, 1958, 182 (4627) : 44 - 44
  • [38] A new calibration technique for interferometric radiometers
    Corbella, I
    Torres, F
    Camps, A
    Bará, J
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES II, 1998, 3498 : 359 - 366
  • [39] A flexible new technique for camera calibration
    Zhang, ZY
    IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2000, 22 (11) : 1330 - 1334
  • [40] A new method based on the construction of hypothetical symmetrical networks for fixture calibration in network analyzers
    Liu, C
    Zhang, SJ
    Xie, L
    Zhu, NH
    ACTA PHYSICA SINICA, 2005, 54 (06) : 2606 - 2610