Investigating the microstructure of soft, microporous matter with synchrotron X-ray tomography

被引:6
|
作者
Metilli, Lorenzo [1 ]
Storm, Malte [2 ]
Bodey, Andrew J. [2 ]
Wanelik, Kaz [2 ]
Tyler, Arwen I. I. [1 ]
Lazidis, Aris [3 ]
Marty-Terrade, Stephanie [4 ]
Simone, Elena [1 ]
机构
[1] Univ Leeds, Sch Food Sci & Nutr, Food Colloids & Bioproc Grp, Leeds LS2 9JT, W Yorkshire, England
[2] Diamond Light Source Ltd, Harwell Sci & Innovat Campus, Didcot OX11 0DE, Oxon, England
[3] Nestle Prod Technol Ctr Confectionery York, Haxby Rd, York YO31 8TA, N Yorkshire, England
[4] Nestle Res, CH-1000 Lausanne 26, Switzerland
基金
英国工程与自然科学研究理事会;
关键词
X-ray tomography; Oleofoams; Image analysis; Bubble; Soft porous matter; ICE-CREAM; COARSENING DYNAMICS; IMAGE-ANALYSIS; STABILIZATION; EVOLUTION; FOAMS; SYSTEMS; DESIGN; SHAPE;
D O I
10.1016/j.matchar.2021.111408
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Soft porous matter is commonly encountered in artificial tissue applications, pharmaceuticals delivery systems and in cosmetic and food products. These materials are typically opaque and tend to deform under very small levels of shear; this makes the characterization of their microstructure very challenging, particularly in the native state. Air-in-oil systems (oleofoams) are an emerging type of soft material with promising applications in cosmetics and foods, which contain air bubbles stabilized by Pickering fat crystals dispersed in a liquid oil phase. Synchrotron radiation X-ray computed tomography (SR - XCT) is a non-invasive, non-destructive technique increasingly used to investigate multiphasic, porous materials, owing to its high flux which enables sub-micron resolution and significant statistics at rapid acquisition speed. While the penetration of high energy X-rays can provide high resolution images and allows the reconstruction of the 3D structure of samples, the experimental setup and measuring parameters need to be carefully designed to avoid sample deformation or beam damage. In this work, a robust methodology for investigating the 3D microstructure of soft, porous matter was developed. Sample preparation and experimental setup were chosen to allow synchrotron tomographic analysis of soft oleofoams with a low melting point (<30 degrees C). In particular, the use of cryogenic conditions (plunge-freeze in liquid nitrogen) provided stability against melting during the acquisition. Additionally, an image processing workflow was designed for analysing the 3D microstructure of the samples using ImageJ. Hence, the size and shape distribution of the air phase, as well as the thickness of the continuous gel phase could be determined for samples with significantly different microstructures (fresh vs. heated). Furthermore, the use of time-resolved X-ray radiography (XRR) allowed to study dynamic changes in the microstructure of the samples during thermal destabilization, visualizing bubble coalescence and growth in optically opaque foam samples with a sub-second timescale.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] Soft X-ray Tomography on HT-7
    陈开云
    胡立群
    丁玥
    马天鹏
    段艳敏
    Plasma Science and Technology, 2009, 11 (04) : 472 - 476
  • [42] Polycapillary optics for soft X-ray imaging and tomography
    Pacella, D.
    Dabagov, S.
    Murtas, F.
    Romano, A.
    Hampai, D.
    Gabellieri, L.
    Mazon, D.
    NUOVO CIMENTO C-COLLOQUIA AND COMMUNICATIONS IN PHYSICS, 2011, 34 (04): : 513 - 520
  • [43] Soft X-ray Tomography on HT-7
    陈开云
    胡立群
    丁玥
    马天鹏
    段艳敏
    Plasma Science and Technology, 2009, (04) : 472 - 476
  • [44] Optimization of soft X-ray tomography on the COMPASS tokamak
    Imrisek, Martin
    Mlynar, Jan
    Loffelmann, Viktor
    Weinzettl, Vladimir
    Odstrcil, Tomas
    Odstrcil, Michal
    Tomes, Matej
    NUKLEONIKA, 2016, 61 (04) : 403 - 408
  • [45] The cellular landscape by cryo soft X-ray tomography
    Groen J.
    Conesa J.J.
    Valcárcel R.
    Pereiro E.
    Biophysical Reviews, 2019, 11 (4) : 611 - 619
  • [46] Soft X-ray Tomography on HT-7
    Chen Kaiyun
    Hu Liqun
    Ding Yue
    Ma Tianpeng
    Duan Yanmin
    PLASMA SCIENCE & TECHNOLOGY, 2009, 11 (04) : 472 - 476
  • [47] Cryo-soft X-ray tomography in the laboratory
    Fahy, Kenneth
    Kapishnikov, Sergey
    Sheridan, Paul
    Fyans, William
    O'Reilly, Fergal
    McEnroe, Tony
    BIOPHYSICAL JOURNAL, 2024, 123 (03) : 421A - 421A
  • [48] Extending Imaging Volume in Soft X-Ray Tomography
    Ekman, Axel
    Chen, Jian-Hua
    Vanslembrouck, Bieke
    Loconte, Valentina
    Larabell, Carolyn A. A.
    Le Gros, Mark A. A.
    Weinhardt, Venera
    ADVANCED PHOTONICS RESEARCH, 2023, 4 (04):
  • [49] Soft X-ray tomography on HT-7
    Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China
    不详
    不详
    Plasma Sci. Technol., 2009, 4 (472-476):
  • [50] The X-ray Extended Range Technique a model for investigating X-ray and electron collision processes at a synchrotron.
    Chantler, Christopher T.
    XXVII INTERNATIONAL CONFERENCE ON PHOTONIC, ELECTRONIC AND ATOMIC COLLISIONS (ICPEAC 2011), PTS 1-15, 2012, 388