Liquid Chromatography with a Fluorimetric Detection Method for Analysis of Paralytic Shellfish Toxins and Tetrodotoxin Based on a Porous Graphitic Carbon Column

被引:23
|
作者
Rey, Veronica [1 ]
Botana, Ana M. [1 ]
Alvarez, Mercedes [2 ]
Antelo, Alvaro [2 ]
Botana, Luis M. [3 ]
机构
[1] Univ Santiago de Compostela, Fac Sci, Dept Analyt Chem, Lugo 27002, Spain
[2] CIFGA SA, Plaza Santo Domingo 20-5a, Lugo 27001, Spain
[3] Univ Santiago de Compostela, Fac Vet, Dept Pharmacol, Lugo 27002, Spain
关键词
paralytic shellfish toxins; tetrodotoxin; porous graphitic carbon; post-column oxidation liquid chromatography; shellfish matrices; POSTCOLUMN OXIDATION; POISONING TOXINS; PRECHROMATOGRAPHIC OXIDATION; QUANTITATIVE-DETERMINATION; FLUORESCENCE DETECTION; VALIDATION; TOXICITY; SEPARATION; SAXITOXIN; OYSTERS;
D O I
10.3390/toxins8070196
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Paralytic shellfish toxins (PST) traditionally have been analyzed by liquid chromatography with either pre- or post-column derivatization and always with a silica-based stationary phase. This technique resulted in different methods that need more than one run to analyze the toxins. Furthermore, tetrodotoxin (TTX) was recently found in bivalves of northward locations in Europe due to climate change, so it is important to analyze it along with PST because their signs of toxicity are similar in the bioassay. The methods described here detail a new approach to eliminate different runs, by using a new porous graphitic carbon stationary phase. Firstly we describe the separation of 13 PST that belong to different groups, taking into account the side-chains of substituents, in one single run of less than 30 min with good reproducibility. The method was assayed in four shellfish matrices: mussel (Mytillus galloprovincialis), clam (Pecten maximus), scallop (Ruditapes decussatus) and oyster (Ostrea edulis). The results for all of the parameters studied are provided, and the detection limits for the majority of toxins were improved with regard to previous liquid chromatography methods: the lowest values were those for decarbamoyl-gonyautoxin 2 (dcGTX2) and gonyautoxin 2 (GTX2) in mussel (0.0001 mg saxitoxin (STX). diHCl kg(-1) for each toxin), decarbamoyl-saxitoxin (dcSTX) in clam (0.0003 mg STX. diHCl kg(-1)), N-sulfocarbamoyl-gonyautoxins 2 and 3 (C1 and C2) in scallop (0.0001 mg STX. diHCl kg(-1) for each toxin) and dcSTX (0.0003 mg STX. diHCl kg(-1)) in oyster; gonyautoxin 2 (GTX2) showed the highest limit of detection in oyster (0.0366 mg STX. diHCl kg(-1)). Secondly, we propose a modification of the method for the simultaneous analysis of PST and TTX, with some minor changes in the solvent gradient, although the detection limit for TTX does not allow its use nowadays for regulatory purposes.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Liquid Chromatography Post-Column Oxidation (PCOX) Method for the Determination of Paralytic Shellfish Toxins in Mussels, Clams, Oysters, and Scallops: Collaborative Study
    van de Riet, Jeffrey
    Gibbs, Ryan S.
    Muggah, Patricia M.
    Rourke, Wade A.
    MacNeil, James D.
    Quilliam, Michael A.
    JOURNAL OF AOAC INTERNATIONAL, 2011, 94 (04) : 1154 - 1176
  • [22] High performance liquid chromatography of a cyclosporin A formulation on a porous graphitic carbon column
    Department of Pharmacy, King's College London, Manresa Road, Chelsea, London, SW3 6LX, United Kingdom
    CHROMATOGRAPHIA, 11-12 (628-636):
  • [23] Determination of Dencichine in Sanchi Using Liquid Chromatography on Porous Graphitic Carbon Column
    Fu Chunmei
    Liu Sankang
    Li Zhangwan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (06) : 834 - 837
  • [24] High performance liquid chromatography of a cyclosporin A formulation on a porous graphitic carbon column
    T. Nazir
    L. A. Gould
    C. Marriott
    G. P. Martin
    M. B. Brown
    Chromatographia, 1997, 46 : 628 - 636
  • [25] High performance liquid chromatography of a cyclosporin A formulation on a porous graphitic carbon column
    Nazir, T
    Gould, LA
    Marriott, C
    Martin, GP
    Brown, MB
    CHROMATOGRAPHIA, 1997, 46 (11-12) : 628 - 636
  • [26] ANALYSIS OF PARALYTIC SHELLFISH POISON AND TETRODOTOXIN BY ION-PAIRING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    NAGASHIMA, Y
    MARUYAMA, J
    NOGUCHI, T
    HASHIMOTO, K
    NIPPON SUISAN GAKKAISHI, 1987, 53 (05) : 819 - 823
  • [27] Hydrophilic interaction liquid chromatography-mass spectrometry for the analysis of paralytic shellfish poisoning (PSP) toxins
    Dell'Aversano, C
    Hess, P
    Quilliam, MA
    JOURNAL OF CHROMATOGRAPHY A, 2005, 1081 (02) : 190 - 201
  • [28] Determination of paralytic shellfish poisoning toxins in cultured microalgae by high-performance liquid chromatography with fluorescence detection
    Hong-Zhi He
    Hua-Bin Li
    Yue Jiang
    Feng Chen
    Analytical and Bioanalytical Chemistry, 2005, 383 : 1014 - 1017
  • [29] Determination of paralytic shellfish poisoning toxins in cultured microalgae by high-performance liquid chromatography with fluorescence detection
    He, HZ
    Li, HB
    Jiang, Y
    Chen, F
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 383 (06) : 1014 - 1017
  • [30] ANALYSIS OF TIOCONAZOLE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH A POROUS GRAPHITIC CARBON COLUMN
    BERRIDGE, JC
    JOURNAL OF CHROMATOGRAPHY, 1988, 449 (01): : 317 - 321