On-line preconcentration and GFAAS determination of trace metals in waters

被引:10
|
作者
Zih-Perényi, K [1 ]
Lásztity, A [1 ]
Kelkó-Lévai, A [1 ]
机构
[1] Eotvos Lorand Univ, Dept Inorgan & Analyt Chem, H-1518 Budapest 112, Hungary
关键词
chelating cellulose; exchanger; medicinal water; highly mineralized water; graphite furnace;
D O I
10.1016/S0026-265X(00)00115-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line separation preconcentration system coupled to electrothermal (graphite furnace) atomic absorption spectrometry was developed. A miniature column packed with iminodiacetic acid ethyl cellulose (IDAEC) was inserted into the loop. A peristaltic pump was used to deliver solutions. A flow of air was driven into the packed column, evacuating it between sample loading, washing and elution. The retained analyte was introduced on-line to graphite furnace using countercurrent elution with HNO(3). The system was applied for the determination of V, Co and Pb in medicinal mineral water samples, and nickel in sea water samples. The detection limits (3 sigma) were 0.058, 0.022, 0.067, 0.062 mug/l for Co, Ph, V, and Ni, respectively. The R.S.D. (n = 5) was < 5% at 0.4-1.0 <mu>g/l concentration range. (C) 2000 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:181 / 185
页数:5
相关论文
共 50 条
  • [31] On-line preconcentration cold vapour atomic absorption spectrometry for the determination of trace mercury in edible seaweeds
    Maria Fernandez-Fernandez, Ana
    Moreda-Piñeiro, Antonio
    Bermejo-Barrera, Pilar
    Journal of Analytical Atomic Spectrometry, 2007, 22 (05): : 573 - 577
  • [32] A new on-line column separation and preconcentration system for the selective determination of trace and ultratrace levels of palladium
    Schuster, M
    Schwarzer, M
    ATOMIC SPECTROSCOPY, 1998, 19 (04) : 121 - 128
  • [33] On-line preconcentration cold vapour atomic absorption spectrometry for the determination of trace mercury in edible seaweeds
    Fernandez, Ana Maria
    Moreda-Pineiro, Antonio
    Bermejo-Barrera, Pilar
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (05) : 573 - 577
  • [34] COMPARISON OF PRECONCENTRATION PROCEDURES FOR TRACE-METALS IN NATURAL-WATERS
    SMITS, J
    NELISSEN, J
    VANGRIEKEN, R
    ANALYTICA CHIMICA ACTA, 1979, 111 (01) : 215 - 226
  • [35] Online preconcentration and determination of trace amounts of zinc in nature waters
    Wei, Liang
    Zhang, Xinshen
    Dai, Yichun
    Huang, Jin
    Xie, Yong-hong
    Xiao, Kai
    JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY, 2008,
  • [36] On-line preconcentration strategies for trace analysis of metabolites by capillary electrophoresis
    Britz-McKibbin, P
    Terabe, S
    JOURNAL OF CHROMATOGRAPHY A, 2003, 1000 (1-2) : 917 - 934
  • [37] On-line system for preconcentration and determination of metals in vegetables by inductively coupled plasma optical emission Spectrometry
    Bezerra, Marcos A.
    dos Santos, Walter N. L.
    Lemos, Valfredo A.
    Korn, Maria das Gracas A.
    Ferreira, Sergio L. C.
    JOURNAL OF HAZARDOUS MATERIALS, 2007, 148 (1-2) : 334 - 339
  • [38] Determination of heavy metals by inductively coupled plasma mass spectrometry after on-line separation and preconcentration
    Dressler, VL
    Pozebon, D
    Curtius, AJ
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1998, 53 (11) : 1527 - 1539
  • [39] The efficiency of a microcolumn of rice bran for on-line trace enrichment in FI-AAS, a highly selective system for on-line preconcentration and determination of copper
    Dadfarnia, S.
    Shabani, A. M. Haji
    Gohari, M.
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2007, 54 (02) : 453 - 458
  • [40] THE SPECTROGRAPHIC DETERMINATION OF TRACE METALS IN SURFACE WATERS
    TABOR, EC
    HALLORAN, TH
    SPECTROCHIMICA ACTA, 1960, 16 (05): : 609 - 610