Experimental performance of a waste heat recovery and utilization system with a looped water-in-steel heat pipe

被引:11
|
作者
Habeebullah, MH [1 ]
Akyurt, M [1 ]
Najjar, YSH [1 ]
El-Kalay, AK [1 ]
机构
[1] King Abdulaziz Univ, Coll Engn, Jeddah 21413, Saudi Arabia
关键词
waste heat recovery; heat pipes; looped systems; experiments;
D O I
10.1016/S1359-4311(97)00023-9
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental facility is described for the recovery, by means of heat-pipes, of waste-heat from exhaust gases, and the utilization of the recovered energy to cool ambient air. To this end, heat of combustion gases, generated in a stainless-steel combustion chamber, is recovered from the stack by means of a heat-pipe system. The recovered heat is utilized to run a modified commercial aqua-ammonia absorption chiller. Chilled water from the chiller is supplied to a fan-coil type cooling tunnel to cool the intake air of a (conceptual) gas turbine engine to boost its performance. It is concluded from test results that the experimental facility performs well, and that it behaves as predicted by modeling and simulation studies. The system is able to extract between 70 and 93% of the technically recoverable energy from exhaust gases, and utilizes the extracted energy to cool air. (C) 1998 Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:595 / 607
页数:13
相关论文
共 50 条
  • [41] WASTE HEAT RECOVERY SYSTEM WITH HEAT PIPE THROUGH PHASE CHANGE IN SMALL BIOMASS FURNACE
    Durcansky, Peter
    Hrabovsky, Peter
    Malcho, Milan
    ENERGY AND CLEAN TECHNOLOGIES CONFERENCE PROCEEDINGS, SGEM 2016, VOL III, 2016, : 351 - 356
  • [42] An experimental study of a heat pipe evacuated tube solar dryer with heat recovery system
    Daghigh, Roonak
    Shafieian, Abdellah
    RENEWABLE ENERGY, 2016, 96 : 872 - 880
  • [43] Experimental study on heat energy recovery and utilization of coal gangue hill based on gravity heat pipe
    Peng, Hong
    Jia, XiangLong
    ENERGY REPORTS, 2022, 8 : 220 - 229
  • [44] Performance evaluation of an ORC unit integrated to a waste heat recovery system in a steel mill
    Ramirez, M.
    Epelde, M.
    de Arteche, M. Gomez
    Panizza, A.
    Hammerschmid, A.
    Baresi, M.
    Monti, N.
    4TH INTERNATIONAL SEMINAR ON ORC POWER SYSTEMS, 2017, 129 : 535 - 542
  • [45] Experimental Analysis of Atypically Long Finned Oscillating Heat Pipe for Ventilation Waste Heat Recovery Application
    MAHAJAN Govinda
    CHO Heejin
    SMITH Aaron
    THOMPSON Scott M.
    JournalofThermalScience, 2020, 29 (03) : 667 - 675
  • [46] Experimental Analysis of Atypically Long Finned Oscillating Heat Pipe for Ventilation Waste Heat Recovery Application
    Govinda Mahajan
    Heejin Cho
    Aaron Smith
    Scott M. Thompson
    Journal of Thermal Science, 2020, 29 : 667 - 675
  • [47] Experimental Analysis of Atypically Long Finned Oscillating Heat Pipe for Ventilation Waste Heat Recovery Application
    Mahajan, Govinda
    Cho, Heejin
    Smith, Aaron
    Thompson, Scott M.
    JOURNAL OF THERMAL SCIENCE, 2020, 29 (03) : 667 - 675
  • [48] Experimental characterization of an n-pentane oscillating heat pipe for waste heat recovery in ventilation systems
    Mahajan, Govinda
    Thompson, Scott M.
    Cho, Heejin
    HELIYON, 2018, 4 (11):
  • [49] Effect of the heat exchanger in the waste heat recovery system on a gasoline engine performance
    Choi, Kyungwook
    Kim, Kibum
    Lee, Kihyung
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART D-JOURNAL OF AUTOMOBILE ENGINEERING, 2015, 229 (04) : 506 - 517
  • [50] Annual performance analysis of heat pump drying system with waste heat recovery
    Zhao Haibo
    Wu Kun