Modeling of Active Fiber Loop Ring-Down Spectroscopy Considering Gain Saturation Behavior of EDFA

被引:17
|
作者
Chu, Tongwei [1 ]
Wang, Pengpeng [1 ]
Zhu, Cunguang [1 ]
机构
[1] Univ Jinan, Sch Phys & Technol, Jinan 250002, Peoples R China
关键词
Erbium-doped fiber amplifiers; Optical fiber couplers; Optical fiber amplifiers; Cavity resonators; Optical fiber losses; Optical fiber theory; EDFA; fiber loop; gain saturation; ring-down; CAVITY RING; SPECTROMETER; INTRACAVITY; TEMPERATURE;
D O I
10.1109/JLT.2019.2949607
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Active fiber loop ring-down spectroscopy (FLRDS) can achieve a high-finesse fiber cavity by introducing the erbium-doped fiber amplifier (EDFA) gain for highly sensitive detection. However, gain saturation behavior of the EDFA induces pulse-to-pulse gain fluctuations, which cause the ring-down signal to deviate from the exponential-decay law and greatly destroy the detection accuracy of active FLRDS. In order to analyze active FLRDS more accurately, a theoretical model of active FLRDS considering the gain saturation behavior of the EDFA is established. The performance of the active FLRDS system is simulated and discussed by using the model. The dependence of the system performance on the initial optical power, the inherent cavity loss, the test-gas concentration and the EDFA location is deeply researched. The model is applicable to the active FLRDS systems used for many sensing applications, such as trace gas, temperature, refractive index, strain, and pressure.
引用
收藏
页码:966 / 973
页数:8
相关论文
共 50 条
  • [31] Measurement of carbon dioxide concentration by fiber-loop ring-down spectroscopy for continuous remote measurement
    Shimizu, Hiromasa
    Noriyasu, Hiroshi
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2014, 53 (11)
  • [32] THEORETICAL AND EXPERIMENTAL RESEARCH ON THE EFFECT OF COUPLER SPLITTING RATIO FOR FIBER LOOP RING-DOWN SPECTROSCOPY TECHNOLOGY
    Zhao, Yong
    Bai, Lu
    Wang, Qi
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2014, 56 (01) : 99 - 103
  • [33] Displacement and level measurement based on fiber loop ring-down technology
    Qin, Xiaozhi
    Wang, Fang
    Zhao, Xinyi
    Liu, Yufang
    Mu, Fanyu
    OPTICS AND LASERS IN ENGINEERING, 2025, 186
  • [34] Sensitivity enhancement of fiber loop cavity ring-down pressure sensor
    Jiang, Yajun
    Yang, Dexing
    Tang, Daqing
    Zhao, Jianlin
    APPLIED OPTICS, 2009, 48 (32) : 6082 - 6087
  • [35] Determination of refractive index by fiber-loop cavity ring-down spectroscopy and a long-period fiber grating
    Lv, Ri-qing
    Zhao, Yong
    Liu, Ming-Chen
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 2016, 44 (05) : 547 - 557
  • [36] Investigation on an evanescent wave fiber-optic absorption sensor based on fiber loop cavity ring-down spectroscopy
    Jiang Meng
    Zhang Weigang
    Zhang Qi
    Liu Yaping
    Liu Bo
    OPTICS COMMUNICATIONS, 2010, 283 (02) : 249 - 253
  • [37] Saturation effect of EDFA on frequency filtering characteristics of active fiber ring resonators
    Luo, JT
    Qian, JR
    Yu, BL
    FIBER OPTIC COMPONENTS, SUBSYSTEMS, AND SYSTEMS FOR TELECOMMUNICATIONS, 2001, 4604 : 50 - 55
  • [38] Effect of EDFA saturation on the frequency filtering characteristic of active fiber ring resonator
    Qian, Jingren
    Luo, Jiatong
    Yu, Benli
    Guangxue Xuebao/Acta Optica Sinica, 2002, 22 (03): : 303 - 307
  • [39] A refractive index sensor based on fiber cavity ring-down spectroscopy
    Wang Yuping
    Ren Wenhua
    SIXTH SYMPOSIUM ON NOVEL OPTOELECTRONIC DETECTION TECHNOLOGY AND APPLICATIONS, 2020, 11455
  • [40] Fiber-optic ring-down spectroscopy using a tunable picosecond gain-switched diode laser
    Andachi, M.
    Nakayama, T.
    Kawasaki, M.
    Kurokawa, S.
    Loock, H.-P.
    APPLIED PHYSICS B-LASERS AND OPTICS, 2007, 88 (01): : 131 - 135