The effect of long-term, daily contact lens wear on corneal sensitivity

被引:78
|
作者
Murphy, PJ
Patel, S
Marshall, J
机构
[1] Glasgow Caledonian Univ, Dept Vis Sci, Glasgow G4 0BA, Lanark, Scotland
[2] Common Serv Agcy, Edinburgh, Midlothian, Scotland
[3] Scottish Execut, Edinburgh, Midlothian, Scotland
[4] St Thomas Hosp, Dept Expt Ophthalmol, London, England
关键词
contact lenses; corneal sensitivity; aesthesiometry; corneal nerve function;
D O I
10.1097/00003226-200104000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To assess the effect of long-term, daily-wear soft contact lenses and rigid gas permeable (RGP) contact lenses on corneal sensitivity using a noninvasive, air-pulse stimulus. Methods. The central and peripheral (temporal, medial, inferior) corneal sensation thresholds of 40 non-lens wearers, 40 soft lens wearers, and 40 RGP lens wearers were assessed using the Non-Contact Corneal Aesthesiometer (NCCA). The individuals who wore contact lenses were grouped according to the number of years of lens wear (10 years or less, 11-20 years, and 21 years or more). Results. Although a significant reduction in corneal sensitivity was found between the contact lens wearers and non-lens wearers (p = 0.000), no difference was found between the two lens-type subgroups (p = 0.939). This pattern of significance was repeated at each of the peripheral test locations. No relationship between corneal sensitivity and years of lens wear was found centrally (r(2) = 0.001) or at any of the peripheral test locations. No significant difference was found between the central corneal sensation thresholds for the different subgroups of lens wear duration (p = 0.469) or for any of the peripheral test locations. Conclusions. Both soft and RGP lens wear produce a similar type of corneal sensitivity loss, although the mechanism for this loss is different for the two lens types. The extent of sensitivity loss is not related to the duration of lens wear and appears to plateau after the first few months of wear. No topographical variation in sensitivity loss was found with lens type or with the duration of lens wear.
引用
收藏
页码:264 / 269
页数:6
相关论文
共 50 条
  • [21] Does Long-term Soft Contact Lens Wear Affect Corneal and Anterior Chamber Parameters?
    Cavdarli, Cemal
    Topcu-Yilmaz, Pinar
    TURK OFTALMOLOJI DERGISI-TURKISH JOURNAL OF OPHTHALMOLOGY, 2018, 48 (04): : 166 - 170
  • [23] Deep corneal stromal opacities associated with long term contact lens wear
    Pimenides, P
    Steele, CF
    McGhee, CNJ
    Bryce, IG
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (01) : 21 - 24
  • [24] Long-term effects of the daily wear of senofilcon A silicone hydrogel contact lenses on corneal and conjunctival tissues
    Guillon, Michel
    Maissa, Cecile
    OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2010, 81 (12) : 680 - 687
  • [25] Reduced Corneal Sensitivity and Sub-Basal Nerve Density in Long-Term Orthokeratology Lens Wear
    Lum, Edward
    Golebiowski, Blanka
    Swarbrick, Helen A.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2017, 43 (04): : 218 - 224
  • [26] Increased Corneal Toricity after Long-Term Orthokeratology Lens Wear
    Chen, Zhi
    Zhou, Jiaqi
    Xue, Feng
    Zhou, Xingtao
    Qu, Xiaomei
    JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [27] CORNEAL EXHAUSTION SYNDROME WITH LONG-TERM WEAR OF CONTACT-LENSES
    SWEENEY, DF
    OPTOMETRY AND VISION SCIENCE, 1992, 69 (08) : 601 - 608
  • [28] Recovery from induced corneal edema and endothelial morphology after long-term PMMA contact lens wear
    McMahon, TT
    Polse, KA
    McNamara, N
    Viana, MAG
    OPTOMETRY AND VISION SCIENCE, 1996, 73 (03) : 184 - 188
  • [29] THE EFFECTS OF LONG-TERM CONTACT-LENS WEAR ON THE ANTERIOR EYE
    SWEENEY, DF
    GAUTHIER, C
    TERRY, R
    CHONG, MS
    HOLDEN, BA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1992, 33 (04) : 1293 - 1293
  • [30] Effect of long-term wear of highly oxygen permeable contact lenses on corneal epithelial cells
    Stapleton, FJ
    Kasses, J
    Kasses, S
    Stern, J
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U365 - U365