Predicting Risk of Endovascular Device Infection in Patients With Staphylococcus aureus Bacteremia (PREDICT-SAB)

被引:44
|
作者
Sohail, M. Rizwan [1 ,2 ]
Palraj, Bharath Raj [1 ]
Khalid, Sana [1 ]
Uslan, Daniel Z. [4 ]
Al-Saffar, Farah [5 ]
Friedman, Paul A. [2 ]
Hayes, David L. [2 ]
Lohse, Christine M. [3 ]
Wilson, Walter R. [1 ]
Steckelberg, James M. [1 ]
Baddour, Larry M. [1 ,2 ]
机构
[1] Mayo Clin, Coll Med, Div Infect Dis, Dept Med, Rochester, MN 55905 USA
[2] Mayo Clin, Coll Med, Div Cardiovasc Dis, Dept Med, Rochester, MN 55905 USA
[3] Mayo Clin, Coll Med, Dept Biostat & Informat, Rochester, MN 55905 USA
[4] Univ Calif Los Angeles, David Geffen Sch Med, Dept Med, Div Infect Dis, Los Angeles, CA 90095 USA
[5] Univ Florida, Hlth Sci Ctr, Dept Med, Jacksonville, FL USA
来源
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY | 2015年 / 8卷 / 01期
基金
美国国家卫生研究院;
关键词
bacteremia; defibrillators; implantable; endocarditis; infection; pacemaker; Staphylococcus aureus; LEAD-ASSOCIATED ENDOCARDITIS; BLOOD-STREAM INFECTIONS; PERMANENT PACEMAKER; CARDIOVERTER-DEFIBRILLATORS; ASSOCIATION; MANAGEMENT; REGISTRY;
D O I
10.1161/CIRCEP.114.002199
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Prompt recognition of underlying cardiovascular implantable electronic device (CIED) infection in patients presenting with Staphylococcus aureus bacteremia (SAB) is critical for optimal management of these cases. The goal of this study was to identify clinical predictors of CIED infection in patients presenting with SAB and no signs of pocket infection. Methods and Results-All cases of SAB in CIED recipients at Mayo Clinic from 2001 to 2011 were retrospectively reviewed. We identified 131 patients with CIED who presented with SAB and had no clinical signs of device pocket infection. Forty-five (34%) of these patients had underlying CIED infection based on clinical or echocardiographic criteria. The presence of a permanent pacemaker rather than an implantable cardioverter-defibrillator (odds ratio, 3.90; 95% confidence interval, 1.65-9.23; P = 0.002), > 1 device-related procedure (odds ratio, 3.30; 95% confidence interval, 1.23-8.86; P = 0.018), and duration of SAB >= 4 days (odds ratio, 5.54; 95% confidence interval, 3.32-13.23; P < 0.001) were independently associated with an increased risk of CIED infection in a multivariable model. The area under the receiver operating characteristics curve for the multivariable model was 0.79, indicating a good discriminatory capacity to distinguish SAB patients with and without CIED infection. Conclusions-Among patients presenting with SAB and no signs of pocket infection, the risk of underlying CIED infection can be calculated based on the type of device, number of device-related procedures, and duration of SAB. We propose that patients without any of these high-risk features have a low risk of underlying CIED infection and may be monitored closely without immediate device extraction. Prospective studies are needed to validate this risk prediction model.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 50 条
  • [41] Cardiovascular Implantable Electronic Device Infection in Patients With Non-Staphylococcus aureus Gram-Positive Coccal Bacteremia
    Madhavan, Malini
    Sohail, Muhammad R.
    Friedman, Paul A.
    Hayes, David L.
    Steckelberg, James M.
    Wilson, Walter R.
    Baddour, Larry M.
    CIRCULATION, 2009, 120 (18) : S648 - S649
  • [42] Does Staphylococcus aureus Bacteriuria Influence Outcome in Patients With Staphylococcus aureus Bacteremia?
    Saravolatz, Louis Donald
    INFECTIOUS DISEASES IN CLINICAL PRACTICE, 2016, 24 (03) : 131 - +
  • [43] Patients at Risk of Complications of Staphylococcus aureus Bloodstream Infection
    del Rio, Ana
    Cervera, Carlos
    Moreno, Asuncion
    Moreillon, Phillipe
    Miro, Jose M.
    CLINICAL INFECTIOUS DISEASES, 2009, 48 : S246 - S253
  • [44] Bacteremia due to non-Staphylococcus aureus gram-positive cocci and risk of cardiovascular implantable electronic device infection
    Chesdachai, Supavit
    Baddour, Larry M.
    Sohail, M. Rizwan
    Palraj, Bharath Raj
    Madhavan, Malini
    Tabaja, Hussam
    Fida, Madiha
    Lahr, Brian D.
    DeSimone, Daniel C.
    HEART RHYTHM O2, 2023, 4 (03): : 207 - 214
  • [45] Clinical outcomes and costs among patients with Staphylococcus aureus bacteremia and orthopedic device infections
    Lalani, Tahaniyat
    Chu, Vivian H.
    Grussemeyer, Chelsea A.
    Reed, Shelby D.
    Bolognesi, Michael P.
    Friedman, Joelle Y.
    Griffiths, Robert I.
    Crosslin, David R.
    Kanafani, Zeina A.
    Kaye, Keith S.
    Corey, G. Ralph
    Fowler, Vance G., Jr.
    SCANDINAVIAN JOURNAL OF INFECTIOUS DISEASES, 2008, 40 (11-12) : 973 - 977
  • [46] STAPHYLOCOCCUS AUREUS BACTEREMIA IN PEDIATRIC PATIENTS WITH CANCER
    Srinivasan, Ashok
    Seifried, Steven
    Zhu, Liang
    Srivastava, Deo K.
    Flynn, Patricia M.
    Bankowski, Matthew J.
    Shenep, Jerry L.
    Hayden, Randall T.
    PEDIATRIC INFECTIOUS DISEASE JOURNAL, 2010, 29 (02) : 172 - 174
  • [47] ECHOCARDIOGRAPHY IN PATIENTS WITH STAPHYLOCOCCUS-AUREUS BACTEREMIA
    PARISER, RH
    LEVITZ, RE
    COOPER, BW
    KLUGER, J
    CLINICAL RESEARCH, 1986, 34 (03): : A862 - A862
  • [48] STAPHYLOCOCCUS-AUREUS BACTEREMIA IN HEMODIALYSIS PATIENTS
    LATOS, DL
    STONE, WJ
    ALFORD, RH
    JOURNAL OF DIALYSIS, 1977, 1 (05): : 399 - 418
  • [49] Survival of Patients With Staphylococcus aureus Bacteremia Reply
    Lopez-Cortes, Luis E.
    Rodriguez-Bano, Jesus
    CLINICAL INFECTIOUS DISEASES, 2014, 58 (04) : 600 - +
  • [50] Retrospective Review of Patients with Staphylococcus aureus Bacteremia
    Yilmaz, Zeynep Burcin
    Duman, Yuecel
    Altunisik Toplu, Sibel
    Memisoglu, Funda
    Kose, Adem
    Ozden, Mehmet
    Bayindir, Yasar
    Ersoy, Yasemin
    FLORA INFEKSIYON HASTALIKLARI VE KLINIK MIKROBIYOLOJI DERGISI, 2024, 29 (02): : 194 - 200