Research on Fault Location for UHV Half-wavelength Transmission Lines

被引:0
|
作者
Wang, Guan [1 ,2 ]
Zhao, Haoran [1 ,2 ]
Hao, Qingshui [3 ]
机构
[1] Shandong Univ, Sch Elect Engn, Jinan 250061, Shandong, Peoples R China
[2] Shandong Prov Key Lab UHV Transmiss Technol & Equ, Jinan, Shandong, Peoples R China
[3] Shandong Greenthink Power Technol Co Ltd, Weifang, Peoples R China
关键词
UHV half-wavelength transmission; fault location; multiple measuring points; wavelet transform;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper mainly elaborated some new problems on the fault location for half-wavelength transmission lines, and studied its fault location method. The results of the research show that the accuracy of the traditional double-terminal fault location method is poor for half-wavelength transmission lines. While adding the traveling wave detection units along the line and using the three-point method can effectively improve fault location accuracy. In addition, simulation results indicate that with the increase of the number of detection points, the accuracy of fault location is gradually improved. But when the distance between two adjacent detection points is reduced to a certain extent, the location accuracy is no longer improved. It is reasonable to take 200-300km between adjacent detection points. For the capacitance tuning network, the arrangement of the measuring points also should ensures that the number of capacitors between the fault point and the three nearby measuring points is sufficiently small.
引用
收藏
页码:1341 / 1345
页数:5
相关论文
共 50 条
  • [21] Two terminal fault location method for half-wavelength transmission line considering length correction
    Shu, Hong-Chun
    Tang, Yu-Tao
    Han, Yi-Ming
    Wu, Yu-Rong
    Dai, Yue
    Jiang, Xiao-Han
    Bo, Zhi -Qian
    [J]. Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2022, 26 (07): : 125 - 132
  • [22] DC Commutation Failure Analysis for the Sending-Side System Fault in Hybrid UHV Half-Wavelength and UHV DC Transmission System
    Zhao, Qianyu
    Jiang, Yilang
    Wang, Shouxiang
    Qin, Xiaohui
    Mu, Hao
    [J]. ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (04) : 319 - 331
  • [23] Steady state voltage characteristic of UHV half-wavelength AC transmission line
    Zhang, Zhiqiang
    Qin, Xiaohui
    Wang, Haohuai
    Xu, Zhengxiong
    Zhang, Dongxia
    Lin, Jiming
    Zheng, Jianchao
    [J]. Dianwang Jishu/Power System Technology, 2011, 35 (09): : 33 - 36
  • [24] Faulted Phase Selection for Half-Wavelength Power Transmission Lines
    Fabian Espinoza, Renzo G.
    Tavares, Maria Cristina
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) : 992 - 1001
  • [25] HALF-WAVELENGTH POWER LINES
    CAPASSO, A
    [J]. ELETTROTECNICA, 1973, 60 (06): : 655 - 666
  • [26] Lightning Fault Location and Visualization for UHV Transmission Lines
    Wang, Xin
    Li, Na
    Li, Kuan
    Sun, Mengmeng
    Li, Yudun
    Zhang, Guohui
    [J]. PROCEEDINGS OF 2020 IEEE 5TH INFORMATION TECHNOLOGY AND MECHATRONICS ENGINEERING CONFERENCE (ITOEC 2020), 2020, : 896 - 899
  • [27] Directional element evaluation applied to half-wavelength transmission lines
    Berrocal, Juan D. Villon
    Tavares, Maria C.
    [J]. ELECTRIC POWER SYSTEMS RESEARCH, 2021, 198
  • [28] Faulted Phase Selection for Half-Wavelength Power Transmission Lines
    Fabian, Renzo
    Tavares, Maria
    [J]. 2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2018,
  • [30] Research on UHV Half Wavelength Ac Transmission Technology
    Peng, Qian
    Hou, Zhongwei
    Wang, Ye
    [J]. 2015 4TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2015), 2015, : 203 - 210