Real-time beam monitoring for error detection in IMRT plans and impact on dose-volume histograms

被引:0
|
作者
Marrazzo, Livia [1 ]
Arilli, Chiara [1 ]
Pasler, Marlies [2 ]
Kusters, Martijn [3 ]
Canters, Richard [3 ]
Fedeli, Luca [4 ]
Calusi, Silvia [4 ]
Casati, Marta [1 ]
Talamonti, Cinzia [1 ,4 ]
Simontacchi, Gabriele [5 ]
Livi, Lorenzo [4 ,5 ]
Pallotta, Stefania [1 ,4 ]
机构
[1] Careggi Univ Hosp, Med Phys Unit, Largo Brambilla 3, I-50134 Florence, Italy
[2] Lake Constance Radiat Oncol Ctr, Singen Friedrichshafen, Germany
[3] Radboud Univ Nijmegen, Dept Radiat Oncol, Med Ctr, Nijmegen, Netherlands
[4] Univ Florence, Dept Expt & Clin Biomed Sci Mario Serio, Florence, Italy
[5] Careggi Univ Hosp, Radiat Oncol Unit, Florence, Italy
关键词
Transmission detector; Quality Assurance; health care; Online dose verification; Detector sensitivity; Organs at risk; RADIATION-THERAPY; TRANSMISSION DETECTOR; VERIFICATION; SYSTEM;
D O I
10.1007/s00066-017-1245-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
This study aimed to test the sensitivity of a transmission detector for online dose monitoring of intensity-modulated radiation therapy (IMRT) for detecting small delivery errors. Furthermore, the correlation of changes in detector output induced by small delivery errors with other metrics commonly employed to quantify the deviations between calculated and delivered dose distributions was investigated. Transmission detector measurements were performed at three institutions. Seven types of errors were induced in nine clinical step-and-shoot (S&S) IMRT plans by modifying the number of monitor units (MU) and introducing small deviations in leaf positions. Signal reproducibility was investigated for short- and long-term stability. Calculated dose distributions were compared in terms of gamma passing rates and dose-volume histogram (DVH) metrics (e.g., D-mean, D-x%, V-x%). The correlation between detector signal variations, gamma passing rates, and DVH parameters was investigated. Both short- and long-term reproducibility was within 1%. Dose variations down to 1 MU (a dagger signal 1.1 +/- 0.4%) as well as changes in field size and positions down to 1 mm (a dagger signal 2.6 +/- 1.0%) were detected, thus indicating high error-detection sensitivity. A moderate correlation of detector signal was observed with gamma passing rates (R-2 = 0.57-0.70), while a good correlation was observed with DVH metrics (R-2 = 0.75-0.98). The detector is capable of detecting small delivery errors in MU and leaf positions, and is thus a highly sensitive dose monitoring device for S&S IMRT for clinical practice. The results of this study indicate a good correlation of detector signal with DVH metrics; therefore, clinical action levels can be defined based on the presented data.
引用
收藏
页码:243 / 254
页数:12
相关论文
共 50 条
  • [31] Comparison of Structure Contouring Efficiency and Dose-Volume Histograms (DVH) of Pinnacle3 and Eclipse Treatment Planning Systems for Prostate IMRT
    Reddy, N.
    Ravi, A.
    Chang, H.
    Lange, C.
    Nori, D.
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 3225 - +
  • [32] Prostate IMRT and VMAT Plan Evaluation Using the PTV Dose-Volume Factor Based On the Guassian Error Function
    Chow, J.
    Jiang, R.
    Kiciak, A.
    Markel, D.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2924 - 2924
  • [33] Dose/Time Volume Histograms of the Oral Mucosa are Predictive of the Use of PEG During IMRT for Oropharyngeal Carcinoma
    Sanguineti, G.
    Gunn, B. G.
    Endres, E. J.
    Fiorino, C.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S388 - S388
  • [34] Real-Time Dose Reconstruction for Treatment Monitoring
    Jiang, Y.
    Gu, X.
    Men, C.
    Jia, X.
    Li, R.
    Lewis, J.
    Jiang, S.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [35] Real-time detection of deviations in VMAT and IMRT beam delivery using a head-mounted detector
    Canters, R. A. M.
    Kusters, J. M. A. M.
    Oellig, J.
    Carrasco, J. P.
    Huizenga, H.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S436 - S437
  • [36] Evaluation of different set-up error corrections on dose-volume metrics in prostate IMRT using CBCT images
    Hirose, Yoshinori
    Nakamura, Mitsuhiro
    Tomita, Tsuneyuki
    Kitsuda, Kenji
    Notogawa, Takuya
    Miki, Katsuhito
    Nakamura, Kiyonao
    Ishigaki, Takashi
    [J]. JOURNAL OF RADIATION RESEARCH, 2014, 55 (05) : 966 - 975
  • [37] Computing Histograms of Local Variables for Real-Time Monitoring using Aggregation Trees
    Jurca, Dan
    Stadler, Rolf
    [J]. 2009 IFIP/IEEE INTERNATIONAL SYMPOSIUM ON INTEGRATED NETWORK MANAGEMENT (IM 2009) VOLS 1 AND 2, 2009, : 367 - 374
  • [38] Real-time optical detection system for monitoring roller condition with automatic error compensation
    Guo, Yuan
    Wang, Yutian
    Liu, Xuan
    [J]. OPTICS AND LASERS IN ENGINEERING, 2014, 53 : 69 - 78
  • [39] Real-time confirmation of electron-beam dose
    Lawrence, CB
    McKeown, J
    Svendsen, EB
    [J]. RADIATION PHYSICS AND CHEMISTRY, 1998, 52 (1-6): : 543 - 547
  • [40] Influence of organ at risk definition on rectal dose-volume histograms in patients with prostate cancer undergoing external-beam radiotherapy
    Boehmer, D
    Kuczer, D
    Badakhshi, H
    Stiefel, S
    Kuschke, W
    Wernecke, KD
    Budach, V
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 (05) : 277 - 282