The Effect of Respiration on Breast Measurement Using Three-dimensional Breast Imaging

被引:13
|
作者
Wang, Chenglong [1 ,2 ]
Liu, Chunjun [1 ,2 ]
Giatsidis, Giorgio [3 ,4 ]
Cheng, Hao [1 ,2 ]
Chen, Lin [1 ,2 ]
Kang, Deni [1 ,2 ]
Panayi, Adriana C. [3 ,4 ]
Luan, Jie [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Plast Surg Hosp, Dept Aesthet & Reconstruct Breast Surg, 33 Ba Da Chu Rd, Beijing 100144, Peoples R China
[2] Peking Union Med Coll, 33 Ba Da Chu Rd, Beijing 100144, Peoples R China
[3] Brigham & Womens Hosp, Dept Surg, Div Plast Surg, Tissue Engn & Wound Healing Lab, 75 Francis St, Boston, MA 02115 USA
[4] Harvard Med Sch, Boston, MA USA
关键词
Three-dimensional imaging; Exhalation; Inhalation; Breast morphology; Breast volume; Mammaplasty; SCANNING TECHNIQUE; VOLUMETRIC CHANGE; AUGMENTATION; SHAPE;
D O I
10.1007/s00266-018-1231-x
中图分类号
R61 [外科手术学];
学科分类号
摘要
BackgroundThree-dimensional (3D) imaging offers new opportunities to enable objective and quantitative analysis of the breast. Unlike scanning of rigid objects, respiration may be one of the factors that can influence the measurement of breast when using 3D imaging. In this study, we aimed to investigate how the different respiratory phases affect 3D morphologic and volumetric evaluations of the breast.MethodsWe performed preoperative 3D breast imaging at the end of expiration (EE) and the end of inspiration (EI). We repeated scans on each respiratory phase, taking four scans in total (EE1, EE2 and EI1, EI2). Using Geomagic Studio 12 software, measurements from the different respiratory phases (EE1 and EI1) were compared for differences in the linear distances of breast. Breast volumetric change error (BVCE) was measured between EE1 and EE2 (R1) and between EI1 and EI2 (R2). A multilevel model was used to analyze the difference of linear-distances parameters between EE1 and EI1 and a paired sample t-test was used to analyze the difference between R1 and R2.ResultsOur study included 13 Chinese women (26 breasts) with a mean age of 32.66.3years. Compared with EI, EE showed a longer sternal notch to the level of the inframammary fold and shorter nipple to midline (p<0.05). During EI, breast projection increased by 0.23cm (95% CI -0.39, -0.08) and breast base width increased by 0.27cm (95% CI -0.46, -0.09). The position of the nipple moved by 0.18cm (95% CI -0.34, -0.03) laterally, 0.41cm (95% CI 0.18, 0.64) cranially, and 0.71cm (95% CI -0.92, -0.51) anteriorly. Although there was no significant difference in BVCE between EE and EI, the result seen with EE appeared to be more consistent.ConclusionsThe results of this study demonstrate that there was no difference in breast volume results when patients are in the expiratory or inspiratory state during 3D breast imaging. This study, however, holds potential benefits to both surgical practice as well as the 3D imaging industry.Level of Evidence IV p id=Par5 This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
引用
收藏
页码:53 / 58
页数:6
相关论文
共 50 条
  • [21] Intraoperative application of three-dimensional imaging for breast surgery
    Tanabe, YN
    Honda, T
    Nakajima, Y
    Sakurai, H
    Nozaki, M
    SCANDINAVIAN JOURNAL OF PLASTIC AND RECONSTRUCTIVE SURGERY AND HAND SURGERY, 2005, 39 (06): : 349 - 352
  • [22] The importance of the pose in three-dimensional imaging of the ptotic breast
    Henseler, Helga
    Ju, Xiangyang
    Ayoub, Ashraf
    Ray, Arup K.
    JOURNAL OF PLASTIC RECONSTRUCTIVE AND AESTHETIC SURGERY, 2013, 66 (11): : 1551 - 1556
  • [23] Three-dimensional photoacoustic imaging of breast tissue phantoms
    Manohar, S
    Kharine, A
    Steenbergen, W
    van Leeuwen, TG
    ALT'03 INTERNATIONAL CONFERENCE ON ADVANCED LASER TECHNOLOGIES: BIOMEDICAL OPTICS, 2003, 5486 : 247 - 251
  • [24] A Methodological Evaluation of Volumetric Measurement Techniques including Three-Dimensional Imaging in Breast Surgery
    Hoeffelin, H.
    Jacquemin, D.
    Defaweux, V.
    Nizet, J. L.
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014
  • [25] Polarimetry Effect in Three-dimensional Contrast Source Inversion for Microwave Breast imaging
    Zhu, Peixian
    Morimoto, Hayatomomaru
    Kidera, Shouhei
    2021 IEEE USNC-URSI RADIO SCIENCE MEETING (JOINT WITH AP-S SYMPOSIUM), 2021, : 75 - 76
  • [26] Effect of three-dimensional intraoperative imaging on surgical outcomes with breast conservation therapy
    Joel, Constance
    Ciampa, Maeghan
    O'Hara, Thomas
    Bandera, Bradley C.
    Mangieri, Christopher W.
    AMERICAN JOURNAL OF SURGERY, 2023, 225 (06): : 1009 - 1012
  • [27] Three-dimensional dose reconstruction of breast cancer treatment using portal imaging
    Louwe, RJW
    Damen, EMF
    van Herk, M
    Minken, AWH
    Törzsök, O
    Mijnheer, BJ
    MEDICAL PHYSICS, 2003, 30 (09) : 2376 - 2389
  • [28] Margin assessment of three-dimensional breast cancer phantoms using terahertz imaging
    Bowman, Tyler
    Walter, Alec
    El-Shenawee, Magda
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IX, 2016, 9700
  • [29] Three-dimensional Microwave Breast Imaging Using Least Electrical Path Method
    Wang, Yifan
    Abbosh, Amin
    2013 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC 2013), 2013, : 1021 - 1023
  • [30] Development of Three-Dimensional Breast Scan and Measurement Application Using Laser Imaging Detection and Ranging Sensor on iPhone
    Han, Woo Yeon
    Lee, Seok Joon
    Chang, Hsien Pin
    Heo, Jin
    Eom, Jin Sup
    Kim, Eun Key
    Han, Hyun Ho
    PLASTIC AND RECONSTRUCTIVE SURGERY, 2023, 152 (06) : 1183E - 1187E