Simulation of passive ventilation strategies towards indoor CO2 concentration reduction for passive houses

被引:25
|
作者
Cakyova, Katarina [1 ,2 ]
Figueiredo, Antonio [3 ]
Oliveira, Rui [3 ]
Rebelo, Filipe [3 ]
Vicente, Romeu [3 ]
Fokaides, Paris [4 ,5 ]
机构
[1] Tech Univ Kosice, Fac Civil Engn, Ctr Res & Innovat Construct, Vysokoskolska 4, Kosice 04200, Slovakia
[2] Brno Univ Technol, Fac Civil Engn, Inst Bldg Struct, Veveri 331-95, Brno 60200, Czech Republic
[3] Univ Aveiro, RISCO Res Ctr Risks & Sustainabil Construct, Civil Engn Dept, Campus Univ Santiago, P-3810193 Aveiro, Portugal
[4] Frederick Univ, Cyprus Sch Engn & Appl Sci, 7 Frederickou Str, CY-1036 Nicosia, Cyprus
[5] Kaunas Univ Technol, Fac Civil Engn & Architecture, 48 Studentu Str, LT-51367 Kaunas, Lithuania
来源
关键词
Passive house; Energy efficiency; Dynamic building simulation; CO2; concentration; Indoor air quality; CARBON-DIOXIDE; AIR-QUALITY; PERFORMANCE; EXPOSURE; BIOEFFLUENTS; OPTIMIZATION; CLIMATE;
D O I
10.1016/j.jobe.2021.103108
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Population awareness and economic growth are responsible for the increasing requirements of indoor thermal comfort in buildings. However, the use of active systems to ensure indoor thermal comfort, contributes for the building sector to be responsible for high levels of energy consumption and consequently greenhouse gas emissions. Passive Houses are one step forward towards low energy demand and indoor environmental quality in buildings. Airtightness of the building's envelope is one of the major PH requirements, that in association with the mechanical ventilation system are responsible to assure adequate ventilation levels. These parameters result in additional challenges towards PH applications in Mediterranean and warm subtropical climates due to the overheating risk, providing new opportunities to explore potential night ventilation strategies. This study is focused on the analysis of different passive ventilation strategies towards indoor CO2 concentration reduction preventing overheating risk, thus assuring high levels of indoor environmental quality. The adopted methodology relied on collected data acquired from interviews performed to Passive Houses residents as the starting point, to identify their major expectations as well as complaints and concerns regarding indoor environmental quality. Following the interviews analysis, whole building dynamic simulation was performed using as a case study a PH building constructed in Cyprus (Tseri Passive House). Three different ventilation scenarios were evaluated: original settings (scenario 1); mechanical ventilation active during the day and turned off during the night (scenario 2); natural night ventilation (scenario 3). An ideal scenario, considering night ventilation through window openings, in which indoor CO2 concentration never exceeded the normative limit of 1000 ppm during a summer design week was achieved.
引用
收藏
页数:13
相关论文
共 50 条
  • [41] CO2 reduction strategies for the Northern Netherlands
    Benders, Rene
    Moll, Henk
    Noorman, Klaas Jan
    Wiersma, Gerwin
    JOURNAL OF INTEGRATIVE ENVIRONMENTAL SCIENCES, 2011, 8 (03) : 219 - 239
  • [42] With transparency towards the reduction of CO2 emissions
    Benen, Marco
    Banik, Tim
    JOT, Journal fuer Oberflaechentechnik, 2024, 64 (03): : 24 - 27
  • [43] Indoor CO2 measurements in Serbian schools and ventilation rate calculation
    Turanjanin, Valentina
    Vutiaevic, Biljana
    Jovanovic, Marina
    La Mirkov, Niko
    Lazovic, Ivan
    ENERGY, 2014, 77 : 290 - 296
  • [44] Numerical Investigation of Indoor CO2 Concentration Distribution in an Apartment
    Zhou, Jiaqing
    Kim, Chang Nyung
    INDOOR AND BUILT ENVIRONMENT, 2011, 20 (01) : 91 - 100
  • [45] Control of indoor CO2 concentration based on a process model
    Skrjanc, Igor
    Subic, Barbara
    AUTOMATION IN CONSTRUCTION, 2014, 42 : 122 - 126
  • [46] PASSIVE MODE LOCKING OF A HIGH-PRESSURE CO2 LASER WITH A CO2 SATURABLE ABSORBER
    GIBSON, AF
    KIMMITT, MF
    ROSITO, CA
    APPLIED PHYSICS LETTERS, 1971, 18 (12) : 546 - &
  • [47] Performance evaluation of wind tower natural ventilation with passive solid tube heat recovery based on CO2 levels
    Liu, Miaomiao
    Jimenez-Bescos, Carlos
    Calautit, John Kaiser
    JOURNAL OF BUILDING ENGINEERING, 2023, 72
  • [48] Towards the Use of Low-Concentration CO2 Sources by Direct Selective Electrocatalytic Reduction
    Mahbub, Muhammad Adib Abdillah
    Das, Debanjan
    Wang, Xin
    Lu, Guilong
    Muhler, Martin
    Schuhmann, Wolfgang
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2025, 64 (07)
  • [49] Cation Effect on Interfacial CO2 Concentration in the Electrochemical CO2 Reduction Reaction
    Malkani, Arnav S.
    Anibal, Jacob
    Xu, Bingjun
    ACS CATALYSIS, 2020, 10 (24): : 14871 - 14876
  • [50] Definition of Optimal Ventilation Rates for Balancing Comfort and Energy Use in Indoor Spaces Using CO2 Concentration Data
    Franco, Alessandro
    Schito, Eva
    BUILDINGS, 2020, 10 (08)