The effect of algorithms on dose distribution in inhomogeneous phantom: Monaco treatment planning system versus monte carlo simulation

被引:1
|
作者
Tugrul, Taylan [1 ]
机构
[1] Van Yuzuncu Yil Univ, Fac Med, Dept Radiat Oncol, Van, Turkey
关键词
Collapse cone; EGSnrc; inhomogeneous phantom; monaco treatment planning system; monte carlo simulation; SMALL FIELDS; PENCIL-BEAM; DOSIMETRIC VERIFICATION; PHOTON; HETEROGENEITIES; ACCURACY; DENSITY; MEDIA; CONE;
D O I
10.4103/jmp.JMP_21_21
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: The aim of this study is to evaluate the dose calculation algorithms commonly used in TPS by using MC simulation in the highly different inhomogeneous region and in the small fields and to provide the following uniquely new information in the study of correction algorithm. Materials and Methods: We compared the dose distribution obtained by Monaco TPS for small fields. Results: When we examine lung medium, for four different fields, we can see that the algorithms begin to differ. In both the lung and bone environment, the percentage differences decrease as the field size increases. In areas less than or equal to 3x3 cm2, there are serious differences between the algorithms. The CC algorithm calculates a low dose value as the photon passes from the lung environment to water environment. We can also see that this algorithm measures a low dose value in voxel as the photon passes from the water medium to the bone medium. In the transition from the water environment to the bone environment or from the bone environment to the water environment, the results of the CC algorithm are not close to MC simulation. Conclusion: The effect of the algorithms used in TPS on dose distribution is very strong, especially in environment with high electron density variation and in applications such as Stereotactic Body Radiotherapy and Intensity Modulated Radiotherapy where small fields are used.
引用
收藏
页码:111 / 115
页数:5
相关论文
共 50 条
  • [1] Comparison of Monaco treatment planning system algorithms and Monte Carlo simulation for small fields in anthropomorphic RANDO phantom: The esophagus case
    Tugrul, Taylan
    [J]. JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (06) : 1370 - 1375
  • [2] Dose calculation using Monte Carlo algorithm of Monaco treatment planning system
    Li, J.
    Doemer, A.
    Harrison, A. S.
    Galvin, J. M.
    Xiao, Y.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (01): : S674 - S674
  • [3] Commissioning of Monaco Monte Carlo IMRT Treatment Planning System
    Li, J.
    Doemer, A.
    Cao, J.
    Podder, T.
    Harrison, A.
    Yu, Y.
    Galvin, J.
    Xiao, Y.
    [J]. MEDICAL PHYSICS, 2009, 36 (06)
  • [4] Patient Dose Distribution Comparison between Monte Carlo Simulation and Treatment Planning System
    Jia, Y.
    Beltran, C.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [5] Monte Carlo simulation of Leksell Gamma Knife: Dose calculations in inhomogeneous phantom "CYCLOPS"
    Moskvin, V
    Timmerman, R
    DesRosiers, C
    Papiez, L
    Randall, M
    DesRosiers, P
    [J]. MEDICAL PHYSICS, 2002, 29 (06) : 1295 - 1295
  • [6] DOSIMETRIC COMMISSIONING OF A MONTE CARLO MODEL IN THE ELEKTA MONACO TREATMENT PLANNING SYSTEM
    Hodgson, D.
    Convery, D.
    Greener, A.
    Misson-Yates, S.
    Thomas, C.
    Footman, M.
    Applegate, K.
    Harrison, L.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S522 - S522
  • [7] Monte Carlo Simulation of Elekta XVI Cone Beam System and Dose Distribution in CTDI Phantom
    Feng, W.
    Deng, J.
    Chi, Y.
    Drake, D.
    Bakalyar, D.
    Yan, D.
    [J]. MEDICAL PHYSICS, 2008, 35 (06) : 2709 - +
  • [8] Experimental evaluation of a GPU-based Monte Carlo dose calculation algorithm in the Monaco treatment planning system
    Paudel, Moti R.
    Kim, Anthony
    Sarfehnia, Arman
    Ahmad, Sayed B.
    Beachey, David J.
    Sahgal, Arjun
    Keller, Brian M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2016, 17 (06): : 230 - 241
  • [9] Application of the Inverse Monte Carlo Treatment Planning System IKO for an Inhomogeneous Dose Prescription in the Sense of Dose Painting
    Rickhey, Mark
    Bogner, Ludwig
    [J]. ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2006, 16 (04): : 307 - 312
  • [10] Verification of the Simplified Monte Carlo Method for Simulation in An Inhomogeneous Phantom
    Mizutani, S.
    Takada, Y.
    Kohno, R.
    Hotta, K.
    Akimoto, T.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3523 - 3523