Renewable energy-based cascade adsorption-compression refrigeration system: Energy, exergy, exergoeconomic and enviroeconomic perspectives

被引:27
|
作者
Gado, Mohamed G. [1 ,2 ,3 ]
Ookawara, Shinichi [1 ,3 ]
Nada, Sameh [1 ,4 ]
Hassan, Hamdy [1 ,5 ]
机构
[1] Egypt Japan Univ Sci & Technol E JUST, Energy Resources Engn Dept, New Borg El Arab City 21934, Alexandria, Egypt
[2] Helwan Univ, Fac Engn El Mattaria, Mech Power Engn Dept, Cairo 11718, Egypt
[3] Tokyo Inst Technol, Dept Chem Sci & Engn, Tokyo 1528552, Japan
[4] Benha Univ, Benha Fac Engn, Mech Engn Dept, Banha 13512, Egypt
[5] Assiut Univ, Fac Engn, Mech Engn Dept, Assiut, Egypt
关键词
Adsorption-compression cascade system; Renewable energy; Energy; Exergy; Exergoeconomic; Environmental; ENVIRONMENTAL 4E ANALYSIS; TECHNOECONOMIC ASSESSMENT; COOLING SYSTEMS; HYBRID; BIOMASS; CYCLE; WIND; PERFORMANCE; DESIGN; SIMULATION;
D O I
10.1016/j.energy.2022.124127
中图分类号
O414.1 [热力学];
学科分类号
摘要
An assessment of the cascade adsorption-compression refrigeration system by adopting renewable energy for cold storage applications based on energy, exergy, exergoeconomic, and enviroeconomic perspectives is presented. The cascade cycle aims to dwindle the electric power of the compression subcycle with reduced condensation pressure. The thermodynamic modeling of the proposed system is developed at climatic conditions of Alexandria/Egypt for two scenarios of renewable systems, including (i) biomass solar (Scenario-I) and (ii) biomass-solar-wind (Scenario-II). The results demonstrate that the COP of the cascade system is ameliorated by 41.6% compared to the conventional compression system; highlighting an energy saving of 42%. The proposed system has an annual average COP and exergetic efficiency of 0.122 and 1.78%, respectively for Scenario-I and 0.124 and 1.8%, respectively for Scenario-II. Scenario-I and Scenario-II deliver refrigeration at 0.235 $/kWh, and 0.237 $/kWh, respectively. Herein, the exergoeconomic parameter for Scenario-I and Scenario-II is 0.70 kWh/$ and 0.69 kWh/$, respectively. It is found that both scenarios alleviate about 32.75 and 5.35 tons of CO2 per annum based on environmental and exergoenvironmental standpoints, respectively. Besides, the enviroeconomic and exergoenvironmental parameters are about 474.90 $/kW and 77.60 $/kW respectively, over the project lifespan of 20 years for both scenarios. (C) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页数:22
相关论文
共 50 条
  • [1] ENERGY AND EXERGY ANALYSIS OF ABSORPTION-COMPRESSION CASCADE REFRIGERATION SYSTEM
    Dixit, Manoj
    Kaushik, S. C.
    Arora, Akhilesh
    [J]. JOURNAL OF THERMAL ENGINEERING, 2016, 2 (06): : 995 - 1006
  • [2] Energy, exergy, environmental, and enviroeconomic (4E) analysis of cascade vapor compression refrigeration systems using nanorefrigerants
    Yılmaz, Metin
    Cimşit, Canan
    Keven, Arzu
    Karaali, Rabi
    [J]. Energy Reports, 2024, 12 : 5521 - 5528
  • [3] Analyzing solar still performance with PV electricity storage: Energy, exergy, exergoeconomic, and enviroeconomic perspectives
    Abd Elbar, Ayman Refat
    Baz, Faisal B.
    Marzouk, S.A.
    Eldesoukey, Ayman
    Salem, Ahmed M.
    [J]. Desalination, 2025, 597
  • [4] Energy, exergy and exergoeconomic analyses of a combined renewable energy system for residential applications
    Zafar, Sayem
    Dincer, Ibrahim
    [J]. ENERGY AND BUILDINGS, 2014, 71 : 68 - 79
  • [5] Energy and exergy analysis of vapor compression-triple effect absorption cascade refrigeration system
    Agarwal, Shyam
    Arora, Akhilesh
    Arora, B. B.
    [J]. ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2020, 23 (03): : 625 - 641
  • [7] Energy, exergy, exergoeconomic and exergoenvironmental analyses of a hybrid renewable energy system with hydrogen fuel cells
    Qi, Xinrui
    Kochan, Orest
    Ma, Zhenjun
    Siarry, Patrick
    Krolczyk, Grzegorz
    Li, Z.
    [J]. INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2024, 52 : 617 - 634
  • [8] Evaluation and Optimization of an Integrated Refrigeration and Dehumidification Process for Solar Energy Cascade Utilization Based on Exergy, Exergoeconomic, and Exergoenvironmental Analyses
    Xu, Aixiang
    Luo, Xinyu
    Zeng, Zhaoduo
    Xie, Fangzhou
    Kou, Guangxiao
    Deng, Chengwei
    Liu, Zhiqiang
    Yang, Sheng
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2024, 12 (06) : 2439 - 2454
  • [9] COMPARISON OF ENERGY AND EXERGY EFFICIENCIES OF ABSORPTION REFRIGERATION SYSTEM WITH MECHANICAL COMPRESSION REFRIGERATION SYSTEM
    Yakar, Gulay
    Karabacak, Rasim
    Altan, Burcin Deda
    [J]. PAMUKKALE UNIVERSITY JOURNAL OF ENGINEERING SCIENCES-PAMUKKALE UNIVERSITESI MUHENDISLIK BILIMLERI DERGISI, 2005, 11 (02): : 161 - 169
  • [10] Energy and exergy analysis of solar hybrid adsorption refrigeration system
    Baiju, V.
    Muraleedharan, C.
    [J]. INTERNATIONAL JOURNAL OF SUSTAINABLE ENGINEERING, 2013, 6 (04) : 289 - 300