A comprehensive exergy-based evaluation on cascade absorption-compression refrigeration system for low temperature applications - exergy, exergoeconomic, and exergoenvironmental assessments

被引:105
|
作者
Mousavi, Seyed Ali [1 ]
Mehrpooya, Mehdi [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Dept Renewable Energies & Environm, Tehran, Iran
关键词
Cascade utilization; Low-temperature applications; Hybrid refrigeration; Exergy analysis; Exergoeconomic analysis; Exergoenvironmental analysis; WATER PRODUCTION PROCESS; CO2 POWER CYCLE; MULTIOBJECTIVE OPTIMIZATION; ENVIRONMENTAL-ANALYSES; ENERGY; HYDROGEN; HEAT; STEAM; WASTE; PLANT;
D O I
10.1016/j.jclepro.2019.119005
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The main target of present work is to assess a new cascade absorption-compression refrigeration system from the exergy, exergoeconomic, and exergoenvironmental standpoints. The combined system is simulated by Aspen HYSYS V10, and Matlab software. This hybrid system is able to supply a cooling duty of 60.65 kW with a coefficient of performance of 0.226. Also, the evaporation temperature of this system is calculated to be -54.62 degrees C. In order to analysis the energy quality and performance of this process, an exergy assessment is conducted. Based on the gained outcomes of exergy evaluation, the total exergy efficiency of process is computed to be 69%. As well as, the overall exergy destruction rate is obtained by 83.4 kW, and the greatest value of irreversibility is found to be in the rectifier (16.05 kW). In continue, to evaluate the process economically, the exergoeconomic evaluation is carried out. It was found that the rectifier has the largest amount of investment cost rate (2.817 $/h). As well as, the highest values of relative cost difference (r) and exergoeconomic factor (f) are related to the compressor and gas heat exchanger, respectively. The environmental impacts of hybrid system are determined by combining life cycle assessment and exergy evaluation (exergoenvironmental method). According to the achieved outcomes, it can be noticed that rectifier and low - pressure pump have the largest and least values of environmental impact. At the final stage of this research, to evaluate the interaction between environmental, technical, and economical aspects of process, the 3D parametric assessment is conducted on devices of the auto - cascade refrigeration system. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:19
相关论文
共 50 条
  • [1] ENERGY AND EXERGY ANALYSIS OF ABSORPTION-COMPRESSION CASCADE REFRIGERATION SYSTEM
    Dixit, Manoj
    Kaushik, S. C.
    Arora, Akhilesh
    [J]. JOURNAL OF THERMAL ENGINEERING, 2016, 2 (06): : 995 - 1006
  • [2] Comparison of an absorption-compression hybrid refrigeration system and the conventional absorption refrigeration system: Exergy analysis
    Pacheco-Cedeno, J. S.
    Rodriguez-Munoz, J. L.
    Ramirez-Minguela, J. J.
    Perez-Garcia, V.
    [J]. INTERNATIONAL JOURNAL OF REFRIGERATION, 2023, 155 : 81 - 92
  • [3] Exergy analysis of a compression-absorption cascade system for refrigeration
    Colorado, D.
    Velazquez, V. M.
    [J]. INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2013, 37 (14) : 1851 - 1865
  • [4] Evaluation and Optimization of an Integrated Refrigeration and Dehumidification Process for Solar Energy Cascade Utilization Based on Exergy, Exergoeconomic, and Exergoenvironmental Analyses
    Xu, Aixiang
    Luo, Xinyu
    Zeng, Zhaoduo
    Xie, Fangzhou
    Kou, Guangxiao
    Deng, Chengwei
    Liu, Zhiqiang
    Yang, Sheng
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2024, 12 (06) : 2439 - 2454
  • [5] Advanced Exergy Analysis of a Compression-Absorption Cascade Refrigeration System
    Colorado-Garrido, Dario
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2019, 141 (04):
  • [6] Advanced Exergy and Exergoeconomic Analysis of Cascade Absorption Refrigeration System Driven by Low-Grade Waste Heat
    Yu, Mengxiao
    Cui, Peizhe
    Wang, Yinglong
    Liu, Zhiqiang
    Zhu, Zhaoyou
    Yang, Sheng
    [J]. ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2019, 7 (19) : 16843 - 16857
  • [7] Energy, exergy, economic and environmental analyses of a cascade absorption-compression refrigeration system using two-stage compression with complete intercooling
    Zhang, Hanyue
    Pan, Xi
    Chen, Jianye
    Xie, Junlong
    [J]. APPLIED THERMAL ENGINEERING, 2023, 225
  • [8] Renewable energy-based cascade adsorption-compression refrigeration system: Energy, exergy, exergoeconomic and enviroeconomic perspectives
    Gado, Mohamed G.
    Ookawara, Shinichi
    Nada, Sameh
    Hassan, Hamdy
    [J]. ENERGY, 2022, 253
  • [9] Energy, exergy, environment and economic analyses and optimization of two-stage absorption-compression combined refrigeration system
    Dixit, Manoj
    Arora, Akhilesh
    Kaushik, S. C.
    [J]. CLEAN TECHNOLOGIES AND ENVIRONMENTAL POLICY, 2017, 19 (09) : 2215 - 2229
  • [10] Energy and exergy analysis of vapor compression-triple effect absorption cascade refrigeration system
    Agarwal, Shyam
    Arora, Akhilesh
    Arora, B. B.
    [J]. ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2020, 23 (03): : 625 - 641